Last data update: Dec 02, 2024. (Total: 48272 publications since 2009)
Records 1-12 (of 12 Records) |
Query Trace: Rossetti R[original query] |
---|
Association between history of SARS-CoV-2 infection and severe systemic adverse events after mRNA COVID-19 vaccination among U.S. adults.
Tompkins LK , Baggs J , Myers TR , Gee JM , Marquez PL , Kennedy SB , Peake D , Dua D , Hause AM , Strid P , Abara W , Rossetti R , Shimabukuro TT , Shay DK . Vaccine 2022 40 (52) 7653-7659 BACKGROUND: Risk of experiencing a systemic adverse event (AE) after mRNA coronavirus disease 2019 (COVID-19) vaccination may be greater among persons with a history of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection; data on serious events are limited. We assessed if adults reporting systemic AEs resulting in emergency department visits or hospitalizations during days 0-7 after mRNA COVID-19 vaccine dose 1 were more likely to have a history of prior SARS-CoV-2 infection compared with persons who reported no or non-severe systemic AEs. METHODS: We conducted a nested case-control study using v-safe surveillance data. Participants were18years and received dose 1 during December 14, 2020May 9, 2021. Cases reported severe systemic AEs 0-7days after vaccination. Three controls were frequency matched per case by age, vaccination date, and days since vaccination. Follow-up surveys collected SARS-CoV-2 histories. RESULTS: Follow-up survey response rates were 38.6% (potential cases) and 56.8% (potential controls). In multivariable analyses including 3,862 case-patients and 11,586 controls, the odds of experiencing a severe systemic AE were 2.4 (Moderna, mRNA-1273; 95% confidence interval [CI]: 1.89, 3.09) and 1.5 (Pfizer-BioNTech, BNT162b2; 95% CI: 1.17, 2.02) times higher among participants with pre-vaccination SARS-CoV-2 histories compared with those without. Medical attention of any kind for symptoms during days 0-7 following dose 2 was not common among case-patients or controls. CONCLUSIONS: History of SARS-CoV-2 infection was significantly associated with severe systemic AEs following dose 1 of mRNA COVID-19 vaccine; the effect varied by vaccine received. Most participants who experienced severe systemic AEs following dose 1 did not require medical attention of any kind for symptoms following dose 2. Vaccine providers can use these findings to counsel patients who had pre-vaccination SARS-CoV-2 infection histories, experienced severe systemic AEs following dose 1, and are considering not receiving additional mRNA COVID-19 vaccine doses. |
Risk-Factors for Exposure Associated With SARS-CoV-2 Detection After Recent Known or Potential COVID-19 Exposures Among Patients Seeking Medical Care at a Large Urban, Public Hospital in Fulton County, Georgia - A Cross-Sectional Investigation.
Smith-Jeffcoat SE , Sleweon S , Koh M , Khalil GM , Schechter MC , Rebolledo PA , Kasinathan V , Hoffman A , Rossetti R , Shragai T , O'Laughlin K , Espinosa CC , Bankamp B , Bowen MD , Paulick A , Gargis AS , Folster JM , da Silva J , Biedron C , Stewart RJ , Wang YF , Kirking HL , Tate JE . Front Public Health 2022 10 809356 We aimed to describe frequency of COVID-19 exposure risk factors among patients presenting for medical care at an urban, public hospital serving mostly uninsured/Medicare/Medicaid clients and risk factors associated with SARS-CoV-2 infection. Consenting, adult patients seeking care at a public hospital from August to November 2020 were enrolled in this cross-sectional investigation. Saliva, anterior nasal and nasopharyngeal swabs were collected and tested for SARS-CoV-2 using RT-PCR. Participant demographics, close contact, and activities ≤14 days prior to enrollment were collected through interview. Logistic regression was used to identify risk factors associated with testing positive for SARS-CoV-2. Among 1,078 participants, 51.8% were male, 57.0% were aged ≥50 years, 81.3% were non-Hispanic Black, and 7.6% had positive SARS-CoV-2 tests. Only 2.7% reported COVID-19 close contact ≤14 days before enrollment; this group had 6.79 adjusted odds of testing positive (95%CI = 2.78-16.62) than those without a reported exposure. Among participants who did not report COVID-19 close contact, working in proximity to ≥10 people (adjusted OR = 2.17; 95%CI = 1.03-4.55), choir practice (adjusted OR = 11.85; 95%CI = 1.44-97.91), traveling on a plane (adjusted OR = 5.78; 95%CI = 1.70-19.68), and not participating in an essential indoor activity (i.e., grocery shopping, public transit use, or visiting a healthcare facility; adjusted OR = 2.15; 95%CI = 1.07-4.30) were associated with increased odds of testing positive. Among this population of mostly Black, non-Hispanic participants seeking care at a public hospital, we found several activities associated with testing positive for SARS-CoV-2 infection in addition to close contact with a case. Understanding high-risk activities for SARS-CoV-2 infection among different communities is important for issuing awareness and prevention strategies. |
Household transmission of SARS-CoV-2 Alpha variant - United States, 2021.
Donnelly MAP , Chuey MR , Soto R , Schwartz NG , Chu VT , Konkle SL , Sleweon S , Ruffin J , Haberling DL , Guagliardo SAJ , Stoddard RA , Anderson RD , Morgan CN , Rossetti R , McCormick DW , Magleby R , Sheldon SW , Dietrich EA , Uehara A , Retchless AC , Tong S , Folster JM , Drobeniuc J , Petway ME , Austin B , Stous S , McDonald E , Jain S , Hudziec MM , Stringer G , Albanese BA , Totten SE , Staples JE , Killerby ME , Hughes L , Matanock A , Beatty M , Tate JE , Kirking HL , Hsu CH . Clin Infect Dis 2022 75 (1) e122-e132 BACKGROUND: In Spring 2021, SARS-CoV-2 B.1.1.7 (Alpha) became the predominant variant in the U.S. Research suggests that Alpha has increased transmissibility compared to non-Alpha lineages. We estimated household secondary infection risk (SIR), assessed characteristics associated with transmission, and compared symptoms of persons with Alpha and non-Alpha infections. METHODS: We followed households with SARS-CoV-2 infection for two weeks in San Diego County and metropolitan Denver, January to April 2021. We collected epidemiologic information and biospecimens for serology, RT-PCR, and whole genome sequencing. We stratified SIR and symptoms by lineage, and identified characteristics associated with transmission using Generalized Estimating Equations. RESULTS: We investigated 127 households with 322 household contacts; 72 households (56.7%) had member(s) with secondary infections. SIRs were not significantly higher for Alpha (61.0% [95% confidence interval (CI) 52.4-69.0%]) than non-Alpha (55.6% [CI 44.7-65.9%], P = 0.49). In households with Alpha, persons who identified as Asian or Hispanic/Latino had significantly higher SIRs than those who identified as White (P = 0.01 and 0.03, respectively). Close contact (e.g., kissing, hugging) with primary cases was associated with increased transmission for all lineages. Persons with Alpha infection were more likely to report constitutional symptoms than persons with non-Alpha (86.9% vs. 76.8%, P = 0.05). CONCLUSIONS: Household SIRs were similar for Alpha and non-Alpha. Comparable SIRs may be due to saturation of transmission risk in households owing to extensive close contact, or true lack of difference in transmission rates. Avoiding close contact within households may reduce SARS-CoV-2 transmission for all lineages among household members. |
Effects of Patient Characteristics on Diagnostic Performance of Self-Collected Samples for SARS-CoV-2 Testing.
Smith-Jeffcoat SE , Koh M , Hoffman A , Rebolledo PA , Schechter MC , Miller HK , Sleweon S , Rossetti R , Kasinathan V , Shragai T , O'Laughlin K , Espinosa CC , Khalil GM , Adeyemo AO , Moorman A , Bauman BL , Joseph K , O'Hegarty M , Kamal N , Atallah H , Moore BL , Bohannon CD , Bankamp B , Hartloge C , Bowen MD , Paulick A , Gargis AS , Elkins C , Stewart RJ , da Silva J , Biedron C , Tate JE , Wang YF , Kirking HL . Emerg Infect Dis 2021 27 (8) 2081-2089 We evaluated the performance of self-collected anterior nasal swab (ANS) and saliva samples compared with healthcare worker-collected nasopharyngeal swab specimens used to test for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). We used the same PCR diagnostic panel to test all self-collected and healthcare worker-collected samples from participants at a public hospital in Atlanta, Georgia, USA. Among 1,076 participants, 51.9% were men, 57.1% were >50 years of age, 81.2% were Black (non-Hispanic), and 74.9% reported >1 chronic medical condition. In total, 8.0% tested positive for SARS-CoV-2. Compared with nasopharyngeal swab samples, ANS samples had a sensitivity of 59% and saliva samples a sensitivity of 68%. Among participants tested 3-7 days after symptom onset, ANS samples had a sensitivity of 80% and saliva samples a sensitivity of 85%. Sensitivity varied by specimen type and patient characteristics. These findings can help physicians interpret PCR results for SARS-CoV-2. |
Evaluation of a Methoprene Aerial Application for the Control of Culiseta melanura (Diptera: Culicidae) in Wetland Larval Habitats
Burtis JC , Poggi JD , Duval TB , Bidlack E , Shepard JJ , Matton P , Rossetti R , Harrington LC . J Med Entomol 2021 58 (6) 2330-2337 Eastern equine encephalitis virus (EEEV) is an arbovirus endemic to the eastern United States. Human cases are rare but can be serious. The primary enzootic vector is Culiseta melanura (Coquillett) (Diptera: Culicidae), an ornithophagic mosquito. We conducted an aerial application of a granular methoprene formulation in Hockomock Swamp (Massachusetts), which represents a focus of EEEV transmission. Water collected from inside and outside Cs. melanura crypts was evaluated in bioassays of early fourth instar Cs. melanura larvae using treated and untreated water. Adult eclosion rates were 36% significantly lower in treated compared with untreated water (P < 0.05). Eclosion rates for water collected from inside crypts were significantly higher (62%) than rates from outside crypts (30%) (P < 0.05), indicating higher efficacy outside crypts. We tested whether reduced methoprene efficacy inside the crypts was due to reduced chemical penetration into this habitat. Chemical water analyses confirmed that methoprene concentrations were lower inside the crypts (0.1 ± 0.05 ppb) compared to water from outside crypts (1.79 ± 0.41 ppb). The susceptibility of Cs. melanura to methoprene was also determined to allow for comparison against concentrations observed in water collected from the field (LC-95: 1.95 ± 0.5 ppb). Overall, methoprene-treated water prevented mosquito development for up to 4 wk, but with a reduction in efficacy between 4- and 6-wk post-application. Our results suggest that aerial methoprene applications can effectively treat open water in wetlands but may not provide efficacious control of Cs. melanura due to an inability to penetrate larval habitats. |
The feasibility of modified HIV and antiretroviral drug testing using self-collected dried blood spots from men who have sex with men.
Luo W , Sullivan V , Chavez PR , Wiatrek SE , Zlotorzynska M , Martin A , Rossetti R , Sanchez T , Sullivan P , MacGowan RJ , Owen SM , Masciotra S . BMC Infect Dis 2021 21 (1) 423 BACKGROUND: In the US, one in six men who have sex with men (MSM) with HIV are unaware of their HIV infection. In certain circumstances, access to HIV testing and viral load (VL) monitoring is challenging. The objective of this study was to evaluate the feasibility of conducting laboratory-based HIV and antiretroviral (ARV) drug testing, and VL monitoring as part of two studies on self-collected dried blood spots (DBS). METHODS: Participants were instructed to collect DBS by self-fingerstick in studies that enrolled MSM online. DBS from the first study (N = 1444) were tested with HIV serological assays approved by the Food and Drug Administration (FDA). A subset was further tested with laboratory-modified serological and VL assays, and ARV levels were measured by mass spectrometry. DBS from the second study (N = 74) were only tested to assess VL monitoring. RESULTS: In the first study, the mail back rate of self-collected DBS cards was 62.9%. Ninety percent of DBS cards were received at the laboratory within 2 weeks from the day of collection, and 98% of the cards had sufficient spots for one assay. Concordance between FDA-approved and laboratory-modified protocols was high. The samples with undetectable ARV had higher VL than samples with at least one ARV drug. In the second study, 70.3% participants returned self-collected DBS cards, and all had sufficient spots for VL assay. High VL was observed in samples from participants who reported low ARV adherence. CONCLUSIONS: In these studies, MSM were able to collect and provide adequate DBS for HIV testing. The FDA-approved and laboratory-modified testing algorithms performed similarly. DBS collected at home may be feasible for HIV testing, ARV measurement, and monitoring viral suppression. |
Mass SARS-CoV-2 Testing in a Dormitory-Style Correctional Facility in Arkansas.
Tompkins LK , Gunn JKL , Cherney B , Ham JE , Horth R , Rossetti R , Bower WA , Benson K , Hagan LM , Crist MB , Mettee Zarecki SL , Dixon MG , Dillaha JA , Patil N , Dusseau C , Ross T , Matthews HS , Garner K , Starks AM , Weiner Z , Bowen MD , Bankamp B , Newton AE , Logan N , Schuh AJ , Trimble S , Pfeiffer H , James AE , Tian N , Jacobs JR , Ruiz F , McDonald K , Thompson M , Cooley L , Honein MA , Rose DA . Am J Public Health 2021 111 (5) e1-e10 Objectives. To assess SARS-CoV-2 transmission within a correctional facility and recommend mitigation strategies.Methods. From April 29 to May 15, 2020, we established the point prevalence of COVID-19 among incarcerated persons and staff within a correctional facility in Arkansas. Participants provided respiratory specimens for SARS-CoV-2 testing and completed questionnaires on symptoms and factors associated with transmission.Results. Of 1647 incarcerated persons and 128 staff tested, 30.5% of incarcerated persons (range by housing unit = 0.0%-58.2%) and 2.3% of staff tested positive for SARS-CoV-2. Among those who tested positive and responded to symptom questions (431 incarcerated persons, 3 staff), 81.2% and 33.3% were asymptomatic, respectively. Most incarcerated persons (58.0%) reported wearing cloth face coverings 8 hours or less per day, and 63.3% reported close contact with someone other than their bunkmate.Conclusions. If testing remained limited to symptomatic individuals, fewer cases would have been detected or detection would have been delayed, allowing transmission to continue. Rapid implementation of mass testing and strict enforcement of infection prevention and control measures may be needed to mitigate spread of SARS-CoV-2 in this setting. (Am J Public Health. Published online ahead of print March 18, 2021: e1-e10. https://doi.org/10.2105/AJPH.2020.306117). |
Evaluation of rapid testing algorithms for venue-based anonymous HIV testing among non-HIV-positive men who have sex with men, National HIV Behavioral Surveillance (NHBS), 2017
Whitby S , Smith A , Rossetti R , Chapin-Bardales J , Martin A , Wejnert C , Masciotra S . J Community Health 2020 45 (6) 1228-1235 HIV rapid testing algorithms (RTAs) using any two orthogonal rapid tests (RTs) allow for on-site confirmation of infection. RTs vary in performance characteristics therefore the selection of RTs in an algorithm may affect identification of infection, particularly if acute. National HIV Behavioral Surveillance (NHBS) assessed RTAs among men who have sex with men recruited using anonymous venue-based sampling. Different algorithms were evaluated among participants who self-reported never having received a positive HIV test result prior to the interview. NHBS project areas performed sequential or parallel RTs using whole blood. Participants with at least one reactive RT were offered anonymous linkage to care and provided a dried blood spot (DBS) for testing at CDC. Discordant results (RT-1 reactive/RT-2 non-reactive) were tested at CDC with lab protocols modified for DBS. DBS were also tested for HIV-1 RNA (VL) and antiretroviral (ARV) drug levels. Of 6500 RTAs, 238 were RT-1 reactive; of those, 97.1% (231/238) had concordant results (RT-1/RT-2 reactive) and 2.9% (7/238) had discordant results. Five DBS associated with discordant results were available for confirmation at CDC. Four had non-reactive confirmatory test results that implied RT-1 false reactivity; one had ambiguous confirmatory test results which was non-reactive in further testing. Regardless of order and type of RT used, RTAs demonstrated high concordant results in the population surveyed. Additional laboratory testing on DBS following discordant results confirmed no infection. Implementing RTAs in the context of anonymous venue-based HIV testing could be an option when laboratory follow-up is not practicable. |
Performance evaluation of the Aptima HIV-1 RNA Quant assay on the Panther system using the standard and dilution protocols
Rossetti R , Smith T , Luo W , Taussig J , Valentine-Graves M , Sullivan P , Ingersoll JM , Kraft CS , Ethridge S , Wesolowski L , Delaney KP , Owen SM , Johnson JA , Masciotra S . J Clin Virol 2020 129 104479 BACKGROUND: Currently, FDA-approved HIV-1 viral load (VL) assays use venipuncture-derived plasma. The Hologic Panther system uses 0.7mL total volume for the Aptima HIV-1 Quant Assay standard (APT-Quant-std) and dilution (APT-Quant-dil) protocols. However, smaller plasma volumes from fingerstick whole blood (FSB) collected in EDTA-microtainer tubes (MCT) could provide an easier sample collection method for HIV-1 VL testing. OBJECTIVES: To evaluate the performance of the APT-Quant-std compared to the Roche CAP/CTM and Abbott m2000RT VL assays and an alternative APTQuant 1:7 dilution protocol, the latter using 100muL of MCT-derived plasma from FSB. STUDY DESIGN: Linearity was determined using commercial HIV-1 RNA plasma controls. Dilutions ranging 1.56-2.95 log10 copies/mL were prepared to determine the APT-Quant-dil Limit of Quantitation (LOQ) using Probit analysis. Specificity of APT-Quant-std was calculated using 326 HIVnegative samples. To evaluate agreement, 329 plasma specimens were tested with APT-Quant-std, CAP/CTM, and m2000RT. Forty-seven matched venipuncture and MCT-derived plasma specimens were tested with APT-Quant-std and APT-Quant-dil. RESULTS: Among the RNA controls, specificity was 99.69 % for APT-Quant-std. The R2 values were 0.988 (APT-Quant-std/CAP/CTM), 0.980 (APT-Quant-std/ m2000RT), and 0.997 (APT-Quant-std/APT-Quant-dil). The APT-Quant-dil LOQ was estimated at 2.7 log10 copies/mL (500 copies/mL) (95 %CI 2.62-2.87). At 2.3 log10 copies/mL (200 copies/mL), the overall agreement was 91.0 % for APT-Quant-std/CAP/CTM, 85.7 % for APT-Quant-std/m2000RT, and 82.9 % for APT-Quant-std/APT-Quant-dil. Quantified APT-Quant-std results were on average 0.2 log10 copies/mL higher than CAP/CTM and m2000RT and 0.14 log10 copies/mL higher than APT-Quant-dil. CONCLUSION: APT-Quant showed similar performance compared to the CAP/CTM and m2000RT assays and remains sensitive and accurate using the dilution protocol. |
Performance evaluation of the MedMira reveal G4 LAB S/P and POC HIV antibody rapid screening tests using plasma and whole blood specimens
Rossetti R , Smith T , Luo W , Masciotra S . J Clin Virol 2020 127 104344 BACKGROUND: The Reveal G4 antibody rapid test is FDA-approved for HIV-1 detection using the versions LAB S/P and POC in CLIA-moderate complexity settings with serum/plasma and whole blood, respectively. The same Reveal tests are CE-marked for HIV-1 and HIV-2 detection in laboratory and point-of-care (POC) settings. OBJECTIVE: We compared the performance of G4 LAB S/P with plasma and POC with whole blood (blood) for detecting early and established HIV-1/HIV-2 infections. STUDY DESIGN: Matched well-characterized plasma and simulated blood were used to evaluate: sensitivity in 104 HIV-1 and 55 HIV-2 established infections, specificity in 49 HIV-negative, and reactivity in early HIV-1 infection in a performance panel (n=38) and 18 plasma panels from seroconverters (SCs, n=183). Median number of days after first RNA-positive was calculated for 13 SCs. Impact of viral suppression (VS) was evaluated in 3 SCs receiving early antiretroviral therapy (ART). RESULTS: Sensitivity was 100 % for HIV-1 and 98.18 % for HIV-2, while specificity was 100 %. All 38 plasma and blood become reactive by Fiebig stage V. Of 18 SCs, 10 had similar reactivity in plasma/blood, 7 showed delayed reactivity in blood, and 1 was nonreactive in plasma/blood. The median days for a G4-reactive after first RNApositive was 13 for plasma and 14 for blood. Long-term VS had no impact on G4 reactivity. CONCLUSIONS: Overall reactivity in early HIV-1 infections is delayed by one day in blood compared to plasma. If FDA-approved for POC settings, the G4 POC is a fast sensitive screening tool for HIV-1/HIV-2-specific IgG even during VS. |
Could HIV-1 RNA be an option as the second step in the HIV diagnostic algorithm
Masciotra S , Luo W , Rossetti R , Smith T , Ethridge S , Delaney KP , Wesolowski LG , Owen SM . Sex Transm Dis 2020 47 S26-S31 BACKGROUND: There is benefit to early HIV-1 diagnosis and treatment, but there is no FDA-approved quantitative assay with a diagnostic claim. We compared the performance of the Hologic Aptima HIV-1 Quant (APT-Quant) and Aptima HIV-1 Qual (APT-Qual) assays for diagnostic use and the performance of a diagnostic algorithm consisting of Bio-Rad BioPlex 2200 HIV Ag-Ab assay (BPC) followed by APT-Quant (two-test) compare to BPC followed by Geenius HIV-1/2 supplemental assay (Geenius) with reflex to APT-Qual (three-test). METHODS: 524 plasma, which included 419 longitudinal specimens from HIV-1 seroconverters (78 were after initiating antiretroviral therapy (ART)) and 105 from ART-naive persons with established HIV-1 infections, were used to evaluate APT-Quant performance for diagnostic use. Specimens from 200 HIV-negative persons were used to measure specificity. For the algorithm comparison, BPC-reactive specimens were evaluated with the two-test or three-test algorithm. McNemar's test was used to compare performance. RESULTS: APT-Quant detected more samples early in infection compared with APT-Qual. APT-Quant specificity was 99.8%. Before ART initiation, the algorithms performed similarly among samples from different stages of infection. After ART initiation, the three-test algorithm performed significantly better (p=0.0233). CONCLUSIONS: APT-Quant has excellent performance for diagnostic use. The two-test algorithm works well in ART-naive samples, but its performance decreases after the IgG response is elicited and with ART-induced suppressed viremia. Providing confirmation and VL with one test result could be advantageous for patient care. However, additional factors and challenges associated with the implementation of this two-test algorithm such as cost, specimen type and collection need further evaluation. |
Evaluation of the performance of the Cepheid Xpert HIV-1 Viral Load Assay for quantitative and diagnostic uses
Wesolowski L , Fowler W , Luo W , Sullivan V , Masciotra S , Smith T , Rossetti R , Delaney K , Oraka E , Chavez P , Ethridge S , Switzer WM , Owen SM . J Clin Virol 2019 122 104214 BACKGROUND: Cepheid's Xpert HIV-1 Viral Load (Xpert VL), a simplified, automated, single-use quantitative assay used with the GeneXpert System, is not FDA approved. OBJECTIVES: Using stored plasma, we conducted a study to assess the ability of Xpert VL to quantify viral load relative to the Roche COBAS AmpliPrep/COBAS TaqMan HIV-1 (Cobas VL) and to examine the use of the Xpert VL as a qualitative diagnostic test. STUDY DESIGN: Following HIV-1 viral stock dilutions, we conducted a probit analysis to identify the concentration where 95 % of specimens had quantified VLs. We also examined Xpert and Cobas log VL correlation in linearity panels; compared the proportion of 220 seroconverter specimens with virus detected using McNemar's test; and tested specimens from persons with untreated, established HIV-1 infection (n=149) and uninfected persons (n=497). Furthermore, we examined Xpert VL as a qualitative test in seroconverter specimens with early (n=20) and later (n=68) acute infections. RESULTS: At 1.80 log10 copies/mL, 95 % of specimens had quantifiable virus using Xpert VL. Xpert and Cobas VLs were highly correlated (R(2)=0.994). The proportion of seroconverter specimens with virus detected using Cobas and with Xpert VL was not statistically different (p=0.0578). Xpert VL detected 97.9 % of established infections, and specificity was 99.80 % (95 % CI 98.87%-99.99%). Xpert VL detected 90 % and 98.5 % of early and later acute infections, respectively. CONCLUSIONS: If approved, Xpert VL could allow U.S. laboratories that cannot bring on large, complex testing platforms to conduct HIV monitoring. An approval for diagnostic use may provide timely identification of HIV infections. |
- Page last reviewed:Feb 1, 2024
- Page last updated:Dec 02, 2024
- Content source:
- Powered by CDC PHGKB Infrastructure