Last data update: Jan 27, 2025. (Total: 48650 publications since 2009)
Records 1-5 (of 5 Records) |
Query Trace: Zervaki O[original query] |
---|
Release of crystalline silica nanoparticles during engineered stone fabrication
Rishi K , Ku BK , Qi C , Thompson D , Wang C , Dozier A , Vogiazi V , Zervaki O , Kulkarni P . ACS Omega 2024 9 (51) 50308-50317 Inhalation exposure to respirable crystalline silica (RCS) during the fabrication of engineered stone-based kitchen countertops has been on the rise in recent years and has become a significant occupational health problem in the United States and globally. Little is known about the presence of nanocrystalline silica (NCS), i.e., particles below 100 nm. We present a methodology to quantify the crystalline silica content in the sub-100 nm size fraction of the aerosol released during engineered stone fabrication using X-ray diffraction (XRD) and Fourier transform infrared (FTIR) spectroscopy. Aerosol was generated in a test chamber designed per EN 1093-3 and sampled using cascade impactors. XRD and FTIR analysis showed the presence of both α-quartz (15-60%) and cristobalite (10-50%) polymorphs in all size fractions. With increasing particle size, the cristobalite content increased. Seventy percent of the total aerosol mass in the sub-100 nm fraction was found to be crystalline silica, qualitatively confirmed by electron diffraction and electron energy loss spectroscopy. The presence of other minerals was detected in all size fractions; no polymeric resin binder was detected in the sub-100 nm fraction. Although the sub-100 nm fraction was about 1% of the aerosol mass, it accounted for 4-24% of the aerosol surface area based on the total lung deposition. If the surface area is a more relevant exposure metric, the assessment of the efficacy of current engineering control systems using mass as an exposure metric may not provide adequate protection. |
Compact, high-flow, water-based, turbulent-mixing, condensation aerosol concentrator for collection of spot samples
Zervaki O , Dionysiou DD , Kulkarni P . Aerosol Sci Technol 2024 A new high-flow, compact aerosol concentrator, using rapid, turbulent mixing to grow aerosol particles into droplets for dry spot sample collection, has been designed and tested. The “TCAC (Turbulent-mixing, Condensation Aerosol Concentrator)” is composed of a saturator for generating hot vapor, a mixing section where the hot vapor mixes with the cold aerosol flow, a growth tube where condensational droplet growth primarily occurs, and a converging nozzle that focuses the droplets into a beam. The prototype concentrator utilizes an aerosol sample flow rate of 4 L min−1. The TCAC was optimized by varying the operating conditions, such as relative humidity of the aerosol flow, mixing flow ratio, vapor temperature, and impaction characteristics. The results showed that particles with a diameter ≥ 25 nm can be grown to a droplet diameter > 1400 nm with near 100% efficiency. Complete activation and growth were observed at relative humidity ≥ 25% of the aerosol sample flow. A consistent spot sample with a diameter of D90 = 1.4 mm (the diameter of a circle containing 90% of the deposited particles) was obtained regardless of the aerosol particle diameter (dp = 20–1900 nm). For fiber counting applications using phase contrast microscopy, the TCAC can reduce the sampling time, or counting uncertainty, by two to three orders of magnitude, compared to the 25-mm-filter collection. The study shows that the proposed mixing-flow scheme enables a compact spot sample collector suitable for handheld or portable applications, while still allowing for high flow rates. © This work was authored as part of the Contributor’s official duties as an Employee of the United States Government and is therefore a work of the United States Government. In accordance with 17 U.S.C. 105, no copyright protection is available for such works under U.S. Law. |
A high-throughput, turbulent-mixing, condensation aerosol concentrator for direct aerosol collection as a liquid suspension
Zervaki O , Dionysiou DD , Kulkarni P . J Aerosol Sci 2024 182 Trace measurement of aerosol chemical composition in workplace atmospheres requires the development of high-throughput aerosol collectors that are compact, hand-portable, and can be operated using personal pumps. We describe the design and characterization of a compact, high flow, Turbulent-mixing Condensation Aerosol-in-Liquid Concentrator (TCALC) that allows direct collection of aerosols as liquid suspensions, for off-line chemical, biological, or microscopy analysis. The TCALC unit, measuring approximately 12 × 16 × 18 cm, operates at an aerosol sample flowrate of up to 10 L min−1, using rapid mixing of a hot flow saturated with water vapor and a cold aerosol sample flow, thereby promoting condensational growth of aerosol particles. We investigated the effect of operating parameters such as vapor temperature, growth tube wall temperature, and aerosol sample flowrate, along with the effect of particle diameter, inlet humidity, aerosol concentration, and operation time on TCALC performance. Nanoparticles with an initial aerodynamic diameter ≥25 nm could grow to droplet diameters >1400 nm with an efficiency ≥80%. Good droplet growth efficiency was achieved for sampled aerosol relative humidity ≥9%. We measured complete aerosol collection for concentrations of ≤3 × 105 cm−3. The results showed good agreement between the particulate mass collected through the liquid collector and direct filter collection. The TCALC eliminates the need for sample preparation and filter digestion during chemical analysis, thereby increasing sample recovery and substantially improving the limit of detection and sensitivity of off-line trace analysis of collected liquid samples. © 2024 |
Characterization of a multi-stage focusing nozzle for collection of spot samples for aerosol chemical analysis
Zervaki O , Dionysiou DD , Kulkarni P . J Aerosol Sci 2023 174 Concentrated collection of aerosol particles on a substrate is essential for their chemical analysis using various microscopy and laser spectroscopic techniques. An impaction-based aerosol concentration system was developed for focused collection of particles using a multi-stage nozzle that consists of a succession of multiple smooth converging stages. Converging sections of the nozzle were designed to focus and concentrate a particle diameter range of 900–2500 nm into a relatively narrower particle beam to obtain particulate deposits with spot diameters of 0.5–1.56 mm. A slightly diverging section before the last contractions was included to allow for better focusing of particles at the lower end of the collectable diameter range. The characterization of this multi-stage nozzle and the impaction-based aerosol concentration system was accomplished both numerically and experimentally. The numerical and experimental trends in collection efficiency and spot diameters agreed well qualitatively; however, the quantitative agreement between numerical and experimental results for wall losses was poor, particularly for larger particle diameters. The resulting concentrated particulate deposit, a spot sample, was analysed using Raman spectroscopy to probe the effect of spot size on analytical sensitivity of measurement. The method's sensitivity was compared against other conventional techniques, such as filtration and aerosol focused impaction, implementing condensational growth. Impaction encompassing the multi-stage focusing nozzle is the only method that can ensure high sensitivity at Reynolds numbers greater than 2000, that can be supported by small pumps which renders such method suitable for portable instrumentation. © 2023 |
NanoSpotTM collector for aerosol sample collection for direct microscopy and spectroscopy analysis
Zervaki O , Stump B , Keady P , Dionysiou DD , Kulkarni P . Aerosol Sci Technol 2023 57 (4) 342-354 We describe design and characterization of an aerosol NanoSpotTM collector, designed for collection of airborne particles on a microscopy substrate for direct electron and optical microscopy, and laser spectroscopy analysis. The collector implements a water-based, laminar-flow, condensation growth technique, followed by impaction onto an optical/electron microscopy substrate or a transmission electron microscopy grid for direct analysis. The compact design employs three parallel growth tubes allowing a sampling flow rate of 1.2 L min−1. Each growth tube consists of three-temperature regions, for controlling the vapor saturation profile and exit dew point. Following the droplet growth, the three streams merge into one flow and a converging nozzle enhances focusing of grown droplets into a tight beam, prior to their final impaction on the warm surface of the collection substrate. Experiments were conducted for the acquisition of the size-dependent collection efficiency and the aerosol concentration effect on the NanoSpotTM collector. Particles as small as 7 nm were activated and collected on the electron microscopy stub. The collected particle samples were analyzed using electron microscopy and Raman spectroscopy for the acquisition of the particle spatial distribution, the spot sample uniformity, and the analyte concentration. A spot deposit of approximately 0.7-mm diameter is formed for particles over a broad particle diameter range, for effective coupling with microscopic and spectroscopic analysis. Finally, the NanoSpotTM collector’s analytical measurement sensitivity for laser Raman analysis and counting statistics for fiber count measurement using optical microscopy were calculated and were compared with those of the conventional aerosol sampling methods. ©, This work was authored as part of the Contributor's official duties as an Employee of the United States Government and is therefore a work of the United States Government. In accordance with 17 USC. 105, no copyright protection is available for such works under US Law. |
- Page last reviewed:Feb 1, 2024
- Page last updated:Jan 27, 2025
- Content source:
- Powered by CDC PHGKB Infrastructure