Last data update: Dec 02, 2024. (Total: 48272 publications since 2009)
Records 1-8 (of 8 Records) |
Query Trace: Wakeman B[original query] |
---|
Pediatric rash illness outbreak with initial positive measles immunoglobulin M antibody test results - American Samoa, March-July 2023
Stefanos R , Schatzman S , Wakeman B , Raines K , Radhakrishnan L , Filardo TD , Crooke SN , Bankamp B , Beard RS , Ng TFF , Marine RL , Tong S , Konrote A , Johansson AM , Ilimaleota AF , Nua MT , Kemble SK , Desmond E , Rota PA , Routh JA , Hancock WT , Sugerman DE , Anesi MS . MMWR Morb Mortal Wkly Rep 2024 73 (45) 1030-1035 On April 24, 2023, the American Samoa Department of Health (ASDoH) declared a public health emergency amid concern about a possible measles outbreak given low 2-dose vaccination coverage at the time. ASDoH had received two positive measles immunoglobulin (Ig) M test results after Flag Day festivities 1 week earlier from vaccinated children. ASDoH performed active case finding, took actions to mitigate transmission, and requested technical assistance from CDC. ASDoH implemented a vaccination campaign to improve suboptimal coverage. Confirmatory molecular testing of specimens from these initial persons under investigation (PUIs) was not possible, but subsequent testing of specimens from additional PUIs by Hawaii State Laboratories Division and CDC ruled out measles. In settings with low measles prevalence, measles antibody testing results have low positive predictive value and can lead to difficulties with interpreting results. Testing for additional pathogens revealed a variety of viruses known to cause common childhood viral exanthems. Both molecular and serologic testing should be performed for all suspected measles cases. To decrease the probability of false-positive IgM results, testing should be reserved for cases that meet the Council of State and Territorial Epidemiologists measles case definition, especially those in persons with no evidence of immunity and with a history of recent international travel. In addition, maintaining high measles vaccination coverage can prevent future outbreaks. |
Notes from the field: Prevalence of previous dengue virus infection among children and adolescents - U.S. Virgin Islands, 2022
Mac VV , Wong JM , Volkman HR , Perez-Padilla J , Wakeman B , Delorey M , Biggerstaff BJ , Fagre A , Gumbs A , Drummond A , Zimmerman B , Lettsome B , Medina FA , Paz-Bailey G , Lawrence M , Ellis B , Rosenblum HG , Carroll J , Roth J , Rossington J , Meeker JR , Joseph J , Janssen J , Ekpo LL , Carrillo M , Hernandez N , Charles P , Tosado R , Soto R , Battle S , Bart SM , Wanga V , Valentin W , Powell W , Battiste Z , Ellis EM , Adams LE . MMWR Morb Mortal Wkly Rep 2023 72 (11) 288-289 In May 2019, the Food and Drug Administration issued approval for Dengvaxia (Sanofi Pasteur), a live-attenuated, chimeric tetravalent dengue vaccine (1). In June 2021, the Advisory Committee on Immunization Practices (ACIP) recommended vaccination with Dengvaxia for children and adolescents aged 9–16 years with laboratory confirmation of previous dengue virus infection and who live in areas with endemic dengue transmission, such as the U.S. Virgin Islands (USVI)† (2). Confirming previous dengue virus infection before vaccine administration (prevaccination screening) is important because 1) although Dengvaxia decreases hospitalization and severe disease from dengue among persons with a previous infection, it increases the risk for these outcomes among persons without a previous infection; 2) many dengue virus infections are asymptomatic; and 3) many patients with symptomatic infections do not seek medical attention or receive appropriate testing (3). Sufficient laboratory evidence of previous dengue virus infection includes a history of laboratory-confirmed dengue§ or a positive serologic test result that meets ACIP-recommended performance standards for prevaccination screening, defined as high specificity (≥98%) and sensitivity (≥75%). A seroprevalence of 20% in the vaccine-eligible population (corresponding to a positive predictive value of ≥90% for a test with minimum sensitivity of 75% and minimum specificity of 98%) is recommended to maximize vaccine safety and minimize the risk for vaccinating persons without a previous dengue virus infection (2). |
Antibody dynamics in children with first or repeat Plasmodium falciparum infections
Rogier E , Nace D , Dimbu PR , Wakeman B , Beeson JG , Drakeley C , Tetteh K , Plucinski M . Front Med (Lausanne) 2022 9 869028 Immunoglobulin (Ig) production during and after infection with Plasmodium parasites is one of the greatest adaptive immune defenses the human host has against this parasite. Infection with P. falciparum has been shown to induce different B cell maturation responses dependent upon the age of the patient, number of previous exposures, and severity of the disease. Described here are dynamics of Ig responses to a panel of 32 P. falciparum antigens by patients followed for 42 days and classified individuals as showing characteristics of an apparent first P. falciparum infection (nave) or a repeat exposure (non-nave). Six parameters were modeled to characterize the dynamics of IgM, IgG(1), IgG(3), and IgA for these two exposure groups with differences assessed among Ig isotypes/subclasses and unique antigens. Nave patients had significantly longer periods of time to reach peak Ig titer (range 4-7 days longer) and lower maximum Ig titers when compared with non-nave patients. Modeled time to seronegativity was significantly higher in non-nave patients for IgM and IgA, but not for the two IgG subclasses. IgG(1) responses to Rh2030, HSP40, and PfAMA1 were at the highest levels for non-nave participants and may be used to predict previous or nascent exposure by themselves. The analyses presented here demonstrate the differences in the development of the Ig response to P. falciparum if the infection represents a boosting response or a primary exposure. Consistency in Ig isotype/subclasses estimates and specific data for P. falciparum antigens can better guide interpretation of seroepidemiological data among symptomatic persons. |
Evaluation of a Multiplex Bead Assay against Single-Target Assays for Detection of IgG Antibodies to SARS-CoV-2.
Mitchell KF , Carlson CM , Nace D , Wakeman BS , Drobeniuc J , Niemeyer GP , Werner B , Hoffmaster AR , Satheshkumar PS , Schuh AJ , Udhayakumar V , Rogier E . Microbiol Spectr 2022 10 (3) e0105422 Serological assays for SARS-CoV-2 antibodies must be validated for performance with a large panel of clinical specimens. Most existing assays utilize a single antigen target and may be subject to reduced diagnostic specificity. This study evaluated a multiplex assay that detects antibodies to three SARS-CoV-2 targets. Human serum specimens (n = 323) with known previous SARS-CoV-2 exposure status were tested on a commercially available multiplex bead assay (MBA) measuring IgG to SARS-CoV-2 spike protein receptor-binding domain (RBD), nucleocapsid protein (NP), and RBD/NP fusion antigens. Assay performance was evaluated against reverse transcriptase PCR (RT-PCR) results and also compared with test results for two single-target commercial assays. The MBA had a diagnostic sensitivity of 89.8% and a specificity of 100%, with serum collection at >28 days following COVID-19 symptom onset showing the highest seropositivity rates (sensitivity: 94.7%). The MBA performed comparably to single-target assays with the ability to detect IgG against specific antigen targets, with 19 (5.9%) discrepant specimens compared to the NP IgG assay and 12 (3.7%) compared to the S1 RBD IgG assay (kappa coefficients 0.92 and 0.88 compared to NP IgG and S1 RBD IgG assays, respectively. These findings highlight inherent advantages of using a SARS-CoV-2 serological test with multiple antigen targets; specifically, the ability to detect IgG against RBD and NP antigens simultaneously. In particular, the 100.0% diagnostic specificity exhibited by the MBA in this study is important for its implementation in populations with low SARS-CoV-2 seroprevalence or where background antibody reactivity to SARS-CoV-2 antigens has been detected. IMPORTANCE Reporting of SARS-CoV-2 infections through nucleic acid or antigen based diagnostic tests severely underestimates the true burden of exposure in a population. Serological data assaying for antibodies against SARS-CoV-2 antigens offers an alternative source of data to estimate population exposure, but most current immunoassays only include a single target for antibody detection. This report outlines a direct comparison of a multiplex bead assay to two other commercial single-target assays in their ability to detect IgG against SARS-CoV-2 antigens. Against a well-defined panel of 323 serum specimens, diagnostic sensitivity and specificity were very high for the multiplex assay, with strong agreement in IgG detection for single targets compared to the single-target assays. Collection of more data for individual- and population-level seroprofiles allows further investigation into more accurate exposure estimates and research into the determinants of infection and convalescent responses. |
Development of a new peptide-bead coupling method for an all peptide-based Luminex multiplexing assay for detection of Plasmodium falciparum antibody responses
Wakeman BS , Shakamuri P , McDonald MA , Weinberg J , Svoboda P , Murphy MK , Kariuki S , Mace K , Elder E , Rivera H , Qvarnstrom Y , Pohl J , Shi YP . J Immunol Methods 2021 499 113148 Using a recombinant protein antigen for antibody testing shows a sum of antibody responses to multiple different immune epitopes existing in the protein antigen. In contrast, the antibody testing to an immunogenic peptide epitope reflects a singular antibody response to the individual peptide epitope. Therefore, using a panel of peptide epitopes provides an advantage for profiling multiple singular antibody responses with potential to estimate recent malaria exposure in human infections. However, transitioning from malaria immune epitope peptide-based ELISA to an all peptide bead-based multiplex Luminex assay presents some challenges including variation in the ability of different peptides to bind beads. The aim of this study was to develop a peptide coupling method while demonstrating the utility of these peptide epitopes from multiple stage antigens of Plasmodium falciparum for measuring antibodies. Successful coupling of peptide epitopes to beads followed three steps: 1) development of a peptide tag appended to the C-terminus of each peptide epitope consisting of beta-alanine-lysine (x 4)--cysteine, 2) bead modification with a high concentration of adipic acid dihydrazide, and 3) use of the peptide epitope as a blocker in place of the traditional choice, bovine serum albumin (BSA). This new method was used to couple 12 peptide epitopes from multiple stage specific antigens of P. falciparum, 1 Anopheles mosquito salivary gland peptide, and 1 Epstein-Barr virus peptide as an assay control. The new method was applied to testing of IgG in pooled samples from 30 individuals with previously repeated malaria exposure in western Kenya and IgM and IgG in samples from 37 U.S. travelers with recent exposure to malaria. The new peptide-bead coupling method and subsequent multiplex Luminex assay showed reliable detection of IgG to all 14 peptides in Kenyan samples. Among 37 samples from U.S. travelers recently diagnosed with malaria, IgM and IgG to the peptide epitopes were detected with high sensitivity and variation. Overall, the U.S. travelers had a much lower positivity rates of IgM than IgG to different peptide epitopes, ranging from a high of 62.2% positive for one epitope to a low of only 5.4% positive for another epitope. In contrast, the travelers had IgG positive rates from 97.3% to 91.9% to various peptide epitopes. Based on the different distribution in IgM and IgG positivity to overall number of peptide epitopes and to the number of pre-erythrocytic, erythrocytic, gametocytic, and salivary stage epitopes at the individual level, four distinct patterns of IgM and IgG responses among the 37 samples from US travelers were observed. Independent peptide-bead coupling and antibody level readout between two different instruments also showed comparable results. Overall, this new coupling method resolves the peptide-bead coupling challenge, is reproducible, and can be applied to any other immunogenic peptide epitopes. The resulting all peptide bead-based multiplex Luminex assay can be expanded to include other peptide epitopes of P. falciparum, different malaria species, or other diseases for surveillance, either in US travelers or endemic areas. |
Framework for Characterizing Longitudinal Antibody Response in Children After Plasmodium falciparum Infection
Rogier E , Nace D , Dimbu PR , Wakeman B , Pohl J , Beeson JG , Drakeley C , Tetteh K , Plucinski M . Front Immunol 2021 12 617951 Human Plasmodium infection produces a robust adaptive immune response. Time courses for 104 children followed for 42 days after initiation of Plasmodium falciparum chemotherapy were assayed for antibody levels to the five isotypes of human immunoglobulins (Ig) and 4 subclasses of IgG for 32 P. falciparum antigens encompassing all 4 parasite stages of human infection. IgD and IgE against these antigens were undetectable at 1:100 serum concentration, but other Ig isotypes and IgG subclasses were consistently observed against all antigens. Five quantitative parameters were developed to directly compare Ig response among isotypes and antigens: C(max), maximum antibody level; Δ(C), difference between C(max) and the antibody level at Day 0; t(max), time in days to reach C(max); t(1/2), Ig signal half-life in days; t(neg), estimated number of days until complete loss of Ig signal. Classical Ig patterns for a bloodborne pathogen were seen with IgM showing early t(max) and IgG production highest among Ig isotypes. However, some unexpected trends were observed such as IgA showing a biphasic pattern for many antigens. Variability among these dynamics of Ig acquisition and loss was noted for different P. falciparum antigens and able to be compared both quantitatively and statistically. This parametrization methodology allows direct comparison of Ig isotypes produced against various Plasmodium antigens following malaria infection, and the same methodology could be applied to other longitudinal serologic studies from P. falciparum or different pathogens. Specifically for P. falciparum seroepidemiological studies, reliable and quantitative estimates regarding the IgG dynamics in human populations can better optimize modeling efforts for serological outputs. |
Assessment of subpatent Plasmodium infection in northwestern Ethiopia
Assefa A , Ahmed AA , Deressa W , Wilson GG , Kebede A , Mohammed H , Sassine M , Haile M , Dilu D , Teka H , Murphy MW , Sergent S , Rogier E , Zhiyong Z , Wakeman BS , Drakeley C , Shi YP , Von Seidlein L , Hwang J . Malar J 2020 19 (1) 108 BACKGROUND: Ethiopia has set a goal for malaria elimination by 2030. Low parasite density infections may go undetected by conventional diagnostic methods (microscopy and rapid diagnostic tests) and their contribution to malaria transmission varies by transmission settings. This study quantified the burden of subpatent infections from samples collected from three regions of northwest Ethiopia. METHODS: Sub-samples of dried blood spots from the Ethiopian Malaria Indicator Survey 2015 (EMIS-2015) were tested and compared using microscopy, rapid diagnostic tests (RDTs), and nested polymerase chain reaction (nPCR) to determine the prevalence of subpatent infection. Paired seroprevalence results previously reported along with gender, age, and elevation of residence were explored as risk factors for Plasmodium infection. RESULTS: Of the 2608 samples collected, the highest positive rate for Plasmodium infection was found with nPCR 3.3% (95% CI 2.7-4.1) compared with RDT 2.8% (95% CI 2.2-3.5) and microscopy 1.2% (95% CI 0.8-1.7). Of the nPCR positive cases, Plasmodium falciparum accounted for 3.1% (95% CI 2.5-3.8), Plasmodium vivax 0.4% (95% CI 0.2-0.7), mixed P. falciparum and P. vivax 0.1% (95% CI 0.0-0.4), and mixed P. falciparum and Plasmodium malariae 0.1% (95% CI 0.0-0.3). nPCR detected an additional 30 samples that had not been detected by conventional methods. The majority of the nPCR positive cases (61% (53/87)) were from the Benishangul-Gumuz Region. Malaria seropositivity had significant association with nPCR positivity [adjusted OR 10.0 (95% CI 3.2-29.4), P < 0.001]. CONCLUSION: Using nPCR the detection rate of malaria parasites increased by nearly threefold over rates based on microscopy in samples collected during a national cross-sectional survey in 2015 in Ethiopia. Such subpatent infections might contribute to malaria transmission. In addition to strengthening routine surveillance systems, malaria programmes may need to consider low-density, subpatent infections in order to accelerate malaria elimination efforts. |
Multiplex serology demonstrate cumulative prevalence and spatial distribution of malaria in Ethiopia
Assefa A , Ali Ahmed A , Deressa W , Sime H , Mohammed H , Kebede A , Solomon H , Teka H , Gurrala K , Matei B , Wakeman B , Wilson GG , Sinha I , Maude RJ , Ashton R , Cook J , Shi YP , Drakeley C , von Seidlein L , Rogier E , Hwang J . Malar J 2019 18 (1) 246 BACKGROUND: Measures of malaria burden using microscopy and rapid diagnostic tests (RDTs) in cross-sectional household surveys may incompletely describe the burden of malaria in low-transmission settings. This study describes the pattern of malaria transmission in Ethiopia using serological antibody estimates derived from a nationwide household survey completed in 2015. METHODS: Dried blood spot (DBS) samples were collected during the Ethiopian Malaria Indicator Survey in 2015 from malarious areas across Ethiopia. Samples were analysed using bead-based multiplex assays for IgG antibodies for six Plasmodium antigens: four human malaria species-specific merozoite surface protein-1 19kD antigens (MSP-1) and Apical Membrane Antigen-1 (AMA-1) for Plasmodium falciparum and Plasmodium vivax. Seroprevalence was estimated by age, elevation and region. The seroconversion rate was estimated using a reversible catalytic model fitted with maximum likelihood methods. RESULTS: Of the 10,278 DBS samples available, 93.6% (9622/10,278) had valid serological results. The mean age of participants was 15.8 years and 53.3% were female. National seroprevalence for antibodies to P. falciparum was 32.1% (95% confidence interval (CI) 29.8-34.4) and 25.0% (95% CI 22.7-27.3) to P. vivax. Estimated seroprevalences for Plasmodium malariae and Plasmodium ovale were 8.6% (95% CI 7.6-9.7) and 3.1% (95% CI 2.5-3.8), respectively. For P. falciparum seroprevalence estimates were significantly higher at lower elevations (< 2000 m) compared to higher (2000-2500 m) (aOR 4.4; p < 0.01). Among regions, P. falciparum seroprevalence ranged from 11.0% (95% CI 8.8-13.7) in Somali to 65.0% (95% CI 58.0-71.4) in Gambela Region and for P. vivax from 4.0% (95% CI 2.6-6.2) in Somali to 36.7% (95% CI 30.0-44.1) in Amhara Region. Models fitted to measure seroconversion rates showed variation nationally and by elevation, region, antigen type, and within species. CONCLUSION: Using multiplex serology assays, this study explored the cumulative malaria burden and regional dynamics of the four human malarias in Ethiopia. High malaria burden was observed in the northwest compared to the east. High transmission in the Gambela and Benishangul-Gumuz Regions and the neglected presence of P. malariae and P. ovale may require programmatic attention. The use of a multiplex assay for antibody detection in low transmission settings has the potential to act as a more sensitive biomarker. |
- Page last reviewed:Feb 1, 2024
- Page last updated:Dec 02, 2024
- Content source:
- Powered by CDC PHGKB Infrastructure