Last data update: Apr 18, 2025. (Total: 49119 publications since 2009)
Records 1-2 (of 2 Records) |
Query Trace: Tsai CS[original query] |
---|
Evaluation of leakage from fume hoods using tracer gas, tracer nanoparticles and nanopowder handling test methodologies
Dunn KH , Tsai CS , Woskie SR , Bennett JS , Garcia A , Ellenbecker MJ . J Occup Environ Hyg 2014 11 (10) D164-73 The most commonly reported control used to minimize workplace exposures to nanomaterials is the chemical fume hood. Studies have shown, however, that significant releases of nanoparticles can occur when materials are handled inside fume hoods. This study evaluated the performance of a new commercially available nano fume hood using three different test protocols. Tracer gas, tracer nanoparticle, and nanopowder handling protocols were used to evaluate the hood. A static test procedure using tracer gas (sulfur hexafluoride) and nanoparticles as well as an active test using an operator handling nanoalumina were conducted. A commercially available particle generator was used to produce sodium chloride tracer nanoparticles. Containment effectiveness was evaluated by sampling both in the breathing zone (BZ) of a mannequin and operator as well as across the hood opening. These containment tests were conducted across a range of hood face velocities (60, 80, and 100 ft/min) and with the room ventilation system turned off and on. For the tracer gas and tracer nanoparticle tests, leakage was much more prominent on the left side of the hood (closest to the room supply air diffuser) although some leakage was noted on the right side and in the BZ sample locations. During the tracer gas and tracer nanoparticle tests, leakage was primarily noted when the room air conditioner was on for both the low and medium hood exhaust airflows. When the room air conditioner was turned off, the static tracer gas tests showed good containment across most test conditions. The tracer gas and nanoparticle test results were well correlated showing hood leakage under the same conditions and at the same sample locations. The impact of a room air conditioner was demonstrated with containment being adversely impacted during the use of room air ventilation. The tracer nanoparticle approach is a simple method requiring minimal setup and instrumentation. However, the method requires the reduction in background concentrations to allow for increased sensitivity. |
Workshop report: strategies for setting occupational exposure limits for engineered nanomaterials
Gordon SC , Butala JH , Carter JM , Elder A , Gordon T , Gray G , Sayre PG , Schulte PA , Tsai CS , West J . Regul Toxicol Pharmacol 2014 68 (3) 305-11 Occupational exposure limits (OELs) are important tools for managing worker exposures to chemicals; however, hazard data for many engineered nanomaterials (ENMs) are insufficient for deriving OELs by traditional methods. Technical challenges and questions about how best to measure worker exposures to ENMs also pose barriers to implementing OELs. New varieties of ENMs are being developed and introduced into commerce at a rapid pace, further compounding the issue of OEL development for ENMs. A Workshop on Strategies for Setting Occupational Exposure Limits for Engineered Nanomaterials, held in September 2012, provided an opportunity for occupational health experts from various stakeholder groups to discuss possible alternative approaches for setting OELs for ENMs and issues related to their implementation. This report summarizes the workshop proceedings and findings, identifies areas for additional research, and suggests potential avenues for further progress on this important topic. |
- Page last reviewed:Feb 1, 2024
- Page last updated:Apr 18, 2025
- Content source:
- Powered by CDC PHGKB Infrastructure