| Comparison of ISO work of breathing and NIOSH breathing resistance measurements for air-purifying respirators
Xu SS , King WP , McClain C , Zhuang Z , Rottach DR . J Occup Environ Hyg 2021 18 (8) 1-9 The National Institute for Occupational Safety and Health's methods and requirements for air-purifying respirator breathing resistance in 42 CFR Part 84 do not include work of breathing. The International Organization for Standardization Technical Committee 94, Subcommittee 15 utilized work of breathing to evaluate airflow resistance for all classes of respiratory protective devices as part of their development of performance standards regarding respiratory protective devices. The objectives of this study were: (1) to evaluate the relationship between the International Organization for Standardization's work of breathing measurements and the National Institute for Occupational Safety and Health's breathing resistance test results; (2) to provide scientific bases for standard development organizations to decide if work of breathing should be adopted; and (3) to establish regression equations for manufacturers and test laboratories to estimate work of breathing measurements using breathing resistance data. A total of 43 respirators were tested for work of breathing at minute ventilation rates of 10, 35, 65, 105, and 135 liters per minute. Breathing resistance obtained at a constant flow rate of 85 liters per minute per National Institute of Occupational Safety and Health protocol was correlated to each of the parameters (total work of breathing, inhalation, and exhalation) obtained from the work of breathing tests. The ratio of work of breathing exhalation to work of breathing inhalation for all air-purifying respirators is similar to the ratio of exhalation to inhalation resistance when tested individually. The ratios were about 0.8 for filtering facepiece respirators, 0.5 for half-masks, and 0.25 for full-facepiece respirators. The National Institute for Occupational Safety and Health's breathing resistance is close to work of breathing's minute ventilation of 35 liters per minute, which represents the common walking/working pace in most workplaces. The work of breathing and the National Institute of Occupational Safety and Health's breathing resistance were found to be strongly and positively correlated (r values of 0.7-0.9) at each work rate for inhalation and exhalation. In addition, linear and multiple regression models (R-squared values of 0.5-0.8) were also established to estimate work of breathing using breathing resistance. Work of breathing was correlated higher to breathing resistance for full-facepiece and half-mask elastomeric respirators than filtering facepiece respirators for inhalation. For exhalation, filtering facepiece respirators were correlated much better than full-facepiece and half-mask elastomeric respirators. Therefore, the National Institute for Occupational Safety and Health's breathing resistance may reasonably be used to predict work of breathing for air-purifying respirators. The results could also be used by manufacturers for product development and evaluation. |
| Speech intelligibility test methodology applied to powered air-purifying respirators used in healthcare
Xu S , Simons J , Yorio P , Rottach D , Zhuang Z , Radonovich L . J Occup Environ Hyg 2020 18 (1) 1-11 Powered air-purifying respirators (PAPRs) are worn to protect workers from hazardous respiratory exposures in a wide range of workplaces, including healthcare. However, PAPRs may diminish the ability of wearers to correctly hear words spoken by others, potentially interfering with safe performance of healthcare duties. Accordingly, the impact of PAPRs during healthcare use on speech intelligibility (SI) and consequently on user safety, usability, and patient care is not well studied. The objectives of this study were to (1) determine a listener's ability to comprehend single-syllable words spoken by a PAPR wearer; (2) determine a PAPR wearer's ability to intelligibly hear and identify single-syllable words spoken by a PAPR wearer; (3) to assess the variability between speakers, listeners, and PAPR models; (4) to investigate the effects of PAPR design features on SI; and (5) inform a SI requirement for certifying future PAPRs for use in healthcare. This study utilized a Modified Rhyme Test to assess SI for PAPRs. The current National Institute for Occupational Safety and Health (NIOSH) methods for assessing SI are limited to the recently introduced PAPR100 respirator class and the class of respirators claiming chemical, biological, radiological, and nuclear (CBRN) protections. Four NIOSH-approved PAPRs were evaluated using four human subjects. Four experimental conditions were examined:(1) Speaker and Listener with no PAPR; (2) Speaker and Listener both wearing PAPRs; (3) Speaker with a PAPR, Listener without a PAPR; and (4) Speaker without a PAPR, Listener with a PAPR resulted in a total of 144 experiments. Statistical analysis showed that the SI performance ratings were not significantly different among the PAPR models, but experimental conditions had significant impact on SI. The pattern of SI across the conditions of the experiment also showed a significant difference depending on PAPR model. The SI performance rating for all PAPRs could meet the current NIOSH CBRN certification requirement for speech intelligibility. |
| A General Framework to Test and Evaluate Filtering Facepiece Respirators Considered for Crisis Capacity Use as a Strategy to Optimize Supply.
Yoon KN , Greenawald LA , Rottach DR , Pollard JP , Yorio PL . J Int Soc Respir Prot 2020 36 (1) 36-51 During a public health emergency, respirator shortages can have a profound impact on the national response, such as for the current coronavirus disease 2019 (COVID-19) pandemic. Due to a severe shortage of respirators (particularly filtering facepiece respirators [FFRs]), there may be contexts in which understanding the performance of FFRs that are approved for use as part of a crisis capacity strategy is desired. This includes FFRs that are not covered under the National Institute for Occupational Safety and Health (NIOSH) Respirator Approval Program because they have been stored past their designated shelf life, have been decontaminated, or are approved by international certification bodies other than NIOSH. The purpose of this document is to provide a general framework to assess the performance of FFRs that are only being used as a crisis capacity strategy. The intended audience are those who are responsible for managing large amounts of FFRs. This framework includes a four-step process consisting of: 1) defining the population of FFRs to be sampled; 2) providing sampling strategy options; 3) inspecting and testing the sampled units; and 4) evaluating the results. In addition to the four-step process, we provide an example of how NIOSH recently evaluated the quality of FFRs sampled from ten U.S. stockpiles. |
| Planning for epidemics and pandemics: assessing the potential impact of extended use and reuse strategies on respirator usage rates to support supply-and-demand planning efforts
Yorio PL , Fisher EM , Kilinc-Balci FS , Rottach D , Harney J , Seaton M , Dahm MM , Niemeier T . J Int Soc Respir Prot 2020 37 (1) 52-60 During epidemics and pandemics healthcare personnel (HCP) are on the front line of disease containment and mitigation. Personal protective equipment (PPE), such as NIOSH-approved N95 filtering facepiece respirators (FFRs), serve an important role in minimizing HCP risks and are in high demand during public health emergencies. Because PPE demand can exceed supply, various public health strategies have been developed to reduce the rate of PPE consumption as supply dwindles. Extended use and limited reuse of N95 FFRs are strategies advocated by many governmental agencies used to increase the number of times a device can be used. Increased use of respirators designed for reuse-such as powered air-purifying respirators (PAPRs) and elastomeric half-mask and full facepiece air-purifying respirators- is another option designed to reduce the continuous need for new devices as the daily need for respirator use increases. Together, these strategies are designed to reduce the number of PPE units that must be discarded daily and, therefore, extend the longevity of available supply. The purpose of this paper is to theoretically estimate the impact of extended use and limited reuse strategies for N95 FFRs and the increased use of reusable respirator options on PPE consumed. The results suggest that a considerable reduction in PPE consumption would result from extended use and limited reuse of N95 FFRs and the increased use of respirators designed for reuse; however, the practical benefits must be balanced with the risks and economic costs. In addition, extended use and reuse strategies must be accompanied by proper procedures to reduce risk. The study is designed to support epidemic and pandemic PPE supply and demand planning efforts. |
| Quality assurance sampling plans in US stockpiles for personal protective equipment: A computer simulation to examine degradation rates
Dubaniewicz MT , Rottach DR , Yorio PL . Health Secur 2019 17 (4) 324-333 Medical countermeasure stockpiles in the United States are designed to support healthcare workers and the public during public health emergencies; they include supplies of personal protective equipment (PPE). As part of typical PPE manufacturing processes, appropriate test methods are used to ensure that the devices provide adequate protective performance. At the time of manufacture, performance is often measured and weighed against an objective standard of quality, resulting in a pass or fail attribute being assigned to individual PPE items and thence to production lots. Incorporating periodic performance testing for stockpiled PPE can ensure that they maintain their protective qualities and integrity over time while in storage. There is an absence of guidance regarding how to design quality assurance programs for stockpiled PPE. The applicability of the Lot Quality Assurance Sampling (LQAS) approach to stockpiled PPE was examined in a previous study that compared and contrasted different sample sizes in recovering the true percentage of defective units in large lots in the LQAS framework. The current study carries this line of inquiry forward by integrating PPE degradation over time and comparing different sampling time intervals in recovering the true underlying degradation rate. The results suggest that product degradation is more easily detected when tested at shorter time intervals and for higher degradation rates. They further suggest that sampling interval groupings can be made based on the proficiency with which they recover the true underlying degradation rate. |
| Quality assurance sampling plans in US stockpiles for personal protective equipment
Yorio PL , Rottach DR , Dubaniewicz M . Health Secur 2019 17 (2) 140-151 Personal protective equipment (PPE) stockpiles in the United States were established to facilitate rapid deployment of medical assets to sites affected by public health emergencies. Large quantities of PPE were introduced into US stockpiles because of the need to protect healthcare and other professionals during these events. Because most stockpiled PPE was acquired during, or immediately following, large-scale public health events, such as pandemic influenza planning (2005-20080), SARS (2003), H1N1 (2009-10), and Ebola (2014-15), aging PPE poses a significant problem. PPE such as N95 filtering face piece respirators were not designed to be stored for long periods, and much of the currently stored PPE has exceeded its manufacturer-assigned shelf life. Given the significant investment in the procurement and storage of PPE, along with projections of consumption during public health emergencies, discarding large quantities of potentially viable PPE is not an attractive option. Although shelf-life extension programs exist for other stockpiled medical assets, no such option is currently available for stockpiled PPE. This article posits stockpile quality assurance sampling plans as a mechanism through which shelf-life extension programs for stockpiled PPE may be achieved. We discuss some of the nuances that should be considered when developing a plan tailored to stockpiles and provide basic decision tools that may be used in the context of a quality assurance program tailored to stockpiled PPE. We also explore basic information by comparing and contrasting different sample size options. |
| Stockpiled N95 Filtering Facepiece Respirator Polyisoprene Strap Performance
Rottach DR , Lei Z . J Int Soc Respir Prot 2017 34 (2) 69-80 Long term storage of personal protective equipment (PPE) in stockpiles is increasingly common in preparation for use during public health emergency responses. Confidence in PPE requires an understanding of the impact of time in storage on all aspects of PPE effectiveness, including protection against inward leakage. Disposable N95 filtering facepiece respirators (FFR) typically rely upon inexpensive elastomeric head straps to provide an effective seal between the filter body and the wearer's face. Annual fit testing provides a measure of assurance that a model fresh from the manufacturer will prove effective, but seal quality may degrade during long term storage. This study examines the stability of a s election of polyisoprene elastomer straps taken from various ages of common N95 FFRs. The tension of the straps at a predetermined strain of 150% was found to differ according to age for one respirator model, though whether due to age or due to manufacturing variations could not be determined. The straps from one manufacturer were found to have notable variation in length, indicating that minor variations in strap tensile properties may not result in significant differences in respirator seal quality. Based on our observations, prolonged storage may affect the tensile properties of headstraps for some models of N95. |
| Simulated effects head movement on contact pressures between headforms and N95 filtering facepiece respirators-part 1: headform model and validation
Lei Z , Ji X , Li N , Yang J , Zhuang Z , Rottach D . Ann Occup Hyg 2014 58 (9) 1175-85 In a respirator fit test, a subject is required to perform a series of exercises that include moving the head up and down and rotating the head left and right. These head movements could affect respirator sealing properties during the fit test and consequently affect fit factors. In a model-based system, it is desirable to have similar capability to predict newly designed respirators. In our previous work, finite element modeling (FEM)-based contact simulation between a headform and a filtering facepiece respirator was carried out. However, the headform was assumed to be static or fixed. This paper presents the first part of a series study on the effect of headform movement on contact pressures-a new headform with the capability to move down (flexion), up (extension), and rotate left and right-and validation. The newly developed headforms were validated for movement by comparing the simulated cervical vertebrae rotation angles with experimental results from the literature. |
| Simulated effects of head movement on contact pressures between headforms and N95 filtering facepiece respirators part 2: simulation
Lei Z , Ji X , Li N , Yang J , Zhuang Z , Rottach D . Ann Occup Hyg 2014 58 (9) 1186-99 Finite element (FE) filtering facepiece respirators (FFRs) were developed and mated to the new headforms with a cervical spine model. The FFRs from three manufacturers included three sizing systems: (i) a single one-size-fits all, (ii) an FFR with two sizes (S/M and M/L), and (iii) an FFR with three sizes (S, L/M, XL). Finite element method (FEM) simulations of 16 headform and respirator combinations (5 headforms and 6 respirators) were used to examine maximum contact pressure changes for five cases: static head, flexion, extension, left rotation, and right rotation. For each of the 16 headform and respirator combinations, maximum contact pressures of the static headform and motile headforms were compared using t-tests. Significant differences on the maximum contact pressures were found in the extension, left rotation and right rotation at the nose (P < 0.005), the left rotation at the top of right cheek (P = 0.03), and the extension at the bottom of left/right cheek (P = 0.01). When separately considering each headform and each FFR manufacturer, the effects of the four head movement cases on the nose maximum contact pressure changes were observed in the simulations with all five headforms and all FFR manufacturers. The effects of the left and right rotations on the chin maximum contact pressure changes were observed in the simulations with the small headform. It was also found that the use of a nose clip could reduce the impact of the head left/right rotations on nose maximum contact pressure changes. In addition, head movements changed pressure contours of the key nose area. Caused by the head movements, the maximum contact pressure changes may affect seal quality, and the increase of the maximum contact pressures could reduce the facial comfort level. |