Last data update: Mar 21, 2025. (Total: 48935 publications since 2009)
Records 1-8 (of 8 Records) |
Query Trace: Pretty JR[original query] |
---|
Large-Format Additive Manufacturing and Machining Using High-Melt-Temperature Polymers. Part I: Real-Time Particulate and Gas-Phase Emissions
Stefaniak AB , Bowers LN , Martin SB Jr , Hammond DR , Ham JE , Wells JR , Fortner AR , Knepp AK , du Preez S , Pretty JR , Roberts JL , du Plessis JL , Schmidt A , Duling MG , Bader A , Virji MA . J Chem Health Saf 2021 28 (3) 190-200 The literature on emissions during material extrusion additive manufacturing with 3-D printers is expanding; however, there is a paucity of data for large-format additive manufacturing (LFAM) machines that can extrude high-melt-temperature polymers. Emissions from two LFAM machines were monitored during extrusion of six polymers: acrylonitrile butadiene styrene (ABS), polycarbonate (PC), high-melt-temperature polysulfone (PSU), poly(ether sulfone) (PESU), polyphenylene sulfide (PPS), and Ultem (poly(ether imide)). Particle number, total volatile organic compound (TVOC), carbon monoxide (CO), and carbon dioxide (CO(2)) concentrations were monitored in real-time. Particle emission rate values (no./min) were as follows: ABS (1.7 × 10(11) to 7.7 × 10(13)), PC (5.2 × 10(11) to 3.6 × 10(13)), Ultem (5.7 × 10(12) to 3.1 × 10(13)), PPS (4.6 × 10(11) to 6.2 × 10(12)), PSU (1.5 × 10(12) to 3.4 × 10(13)), and PESU (2.0 to 5.0 × 10(13)). For print jobs where the mass of extruded polymer was known, particle yield values (g(-1) extruded) were as follows: ABS (4.5 × 10(8) to 2.9 × 10(11)), PC (1.0 × 10(9) to 1.7 × 10(11)), PSU (5.1 × 10(9) to 1.2 × 10(11)), and PESU (0.8 × 10(11) to 1.7 × 10(11)). TVOC emission yields ranged from 0.005 mg/g extruded (PESU) to 0.7 mg/g extruded (ABS). The use of wall-mounted exhaust ventilation fans was insufficient to completely remove airborne particulate and TVOC from the print room. Real-time CO monitoring was not a useful marker of particulate and TVOC emission profiles for Ultem, PPS, or PSU. Average CO(2) and particle concentrations were moderately correlated (r (s) = 0.76) for PC polymer. Extrusion of ABS, PC, and four high-melt-temperature polymers by LFAM machines released particulate and TVOC at levels that could warrant consideration of engineering controls. LFAM particle emission yields for some polymers were similar to those of common desktop-scale 3-D printers. |
Large-Format Additive Manufacturing and Machining Using High-Melt-Temperature Polymers. Part II: Characterization of Particles and Gases
Stefaniak AB , Bowers LN , Martin SB Jr , Hammond DR , Ham JE , Wells JR , Fortner AR , Knepp AK , du Preez S , Pretty JR , Roberts JL , du Plessis JL , Schmidt A , Duling MG , Bader A , Virji MA . J Chem Health Saf 2021 28 (4) 268-278 Extrusion of high-melt-temperature polymers on large-format additive manufacturing (LFAM) machines releases particles and gases, though there is no data describing their physical and chemical characteristics. Emissions from two LFAM machines were monitored during extrusion of acrylonitrile butadiene styrene (ABS) and polycarbonate (PC) polymers as well as high-melt-temperature Ultem (poly(ether imide)), polysulfone (PSU), poly(ether sulfone) (PESU), and polyphenylene sulfide (PPS) polymers. Filter samples of particles were collected for quantification of elements and bisphenol A and S (BPA, BPS) and visualization of morphology. Individual gases were quantified on substance-specific media. Aerosol sampling demonstrated that concentrations of elements were generally low for all polymers, with a maximum of 1.6 mg/m(3) for iron during extrusion of Ultem. BPA, an endocrine disruptor, was released into air during extrusion of PC (range: 0.4 ± 0.1 to 21.3 ± 5.3 μg/m(3)). BPA and BPS (also an endocrine disruptor) were released into air during extrusion of PESU (BPA, 2.0-8.7 μg/m(3); BPS, 0.03-0.07 μg/m(3)). Work surfaces and printed parts were contaminated with BPA (<8-587 ng/100 cm(2)) and BPS (<0.22-2.5 ng/100 cm(2)). Gas-phase sampling quantified low levels of respiratory irritants (phenol, SO(2), toluene, xylenes), possible or known asthmagens (caprolactam, methyl methacrylate, 4-oxopentanal, styrene), and possible occupational carcinogens (benzene, formaldehyde, acetaldehyde) in air. Characteristics of particles and gases released by high-melt-temperature polymers during LFAM varied, which indicated the need for polymer-specific exposure and risk assessments. The presence of BPA and BPS on surfaces revealed a previously unrecognized source of dermal exposure for additive manufacturing workers using PC and PESU polymers. |
An evaluation of the relationship among urine, air, and hand measures of exposure to bisphenol A (BPA) in US manufacturing workers
Hines CJ , Christianson AL , Jackson MV , Ye X , Pretty JR , Arnold JE , Calafat AM . Ann Work Expo Health 2018 62 (7) 840-851 Background: Exposure to bisphenol A (BPA) can be assessed using external and internal exposure measures. We examined the relationship between two measures of external BPA exposure (air and hand-wipe samples) and one of internal exposure (total BPA in urine) for a group of US manufacturing workers. Methods: During 2013-2014, we recruited 78 workers from six US companies that made BPA or made products with BPA. We quantified BPA in seven urine samples, two full-shift air samples and in pre- and end-shift hand-wipe samples collected from workers over 2 consecutive days. We examined correlations between creatinine-corrected urinary concentrations of total BPA (total BPACR) and BPA levels in air and hand wipes using Pearson's correlation coefficient. We also applied mixed-effects regression models to examine the relationship between total BPACR with BPA in air (urine~air model) and with BPA in end-shift hand wipes (urine~hand model), separately and together (urine~air+hand model), after adjusting for covariates. Results: End-shift total BPACR strongly correlated with BPA in air (rp = 0.79, P < 0.0001) and nearly as strongly with BPA in end-shift hand wipes (rp = 0.75, P < 0.0001). In mixed-effect models, BPA air concentration and end-shift hand-wipe BPA level were significantly and positively associated with end-shift total BPACR (P < 0.0001 each). We found a significant effect of the Day 1 BPA air concentration on Day 2 total BPACR (P = 0.0104). When BPA air concentration and end-shift hand-wipe BPA level were in the same model, the air concentration (P < 0.0001) was more significant than the hand-wipe level (P = 0.0106). Conclusion: BPA levels in air and end-shift hand wipes strongly correlated with total BPACR, suggesting that both inhalation and dermal contract were likely exposure routes; however, inhalation, on average, appeared to be a more dominant exposure route than dermal contact for these manufacturing workers. |
Air, hand wipe, and surface wipe sampling for bisphenol A (BPA) among workers in industries that manufacture and use BPA in the United States
Hines CJ , Jackson MV , Christianson AL , Clark JC , Arnold JE , Pretty JR , Deddens JA . J Occup Environ Hyg 2017 14 (11) 882-897 For decades, bisphenol A (BPA) has been used in making polycarbonate, epoxy, and phenolic resins and certain investment casting waxes, yet published exposure data are lacking for U.S. manufacturing workers. In 2013-2014, BPA air and hand exposures were quantified for 78 workers at six U.S. companies making BPA or BPA-based products. Exposure measures included an inhalable-fraction personal air sample on each of two consecutive work days (n = 146), pre- and end-shift hand wipe samples on the second day (n = 74 each), and surface wipe samples (n = 88). Potential determinants of BPA air and end-shift hand exposures (after natural log transformation) were assessed in univariate and multiple regression mixed models. The geometric mean (GM) BPA air concentration was 4.0 microg/m3 (maximum 920 microg/m3). The end-shift GM BPA hand level (26 microg/sample) was 10-times higher than the pre-shift level (2.6 microg/sample). BPA air and hand exposures differed significantly by industry and job. BPA air concentrations and end-shift hand levels were highest in the BPA-filled wax manufacturing/reclaim industry (GMAir = 48 microg/m3, GMHand-End = 130 microg/sample) and in the job of working with molten BPA-filled wax (GMAir = 43 microg/m3, GMHand-End = 180 microg/sample), and lowest in the phenolic resins industry (GMAir = 0.85 microg/m3, GMHand-End = 0.43 microg/sample) and in the job of flaking phenolic resins (GMAIR = 0.62 microg/m3, GMHand-End = 0.38 microg/sample). Determinants of increased BPA air concentration were industry, handling BPA containers, spilling BPA, and spending ≥50% of the shift in production areas; increasing age was associated with lower air concentrations. BPA hand exposure determinants were influenced by high values for two workers; for all other workers, tasks involving contact with BPA-containing materials and spending ≥50% of the shift in production areas were associated with increased BPA hand levels. Surface wipe BPA levels were significantly lower in eating/office areas (GM = 9.3 microg/100 cm2) than in production areas (GM = 140 microg/100 cm2). In conclusion, worker BPA exposure was associated with tasks and conditions affecting both inhalation and dermal exposure. The potential for BPA-related health effects among these workers is unknown. |
Detection of 5-fluorouracil surface contamination in near real time
Smith JP , Sammons DL , Pretty JR , Kurtz KS , Robertson SA , DeBord DG , Connor TH , Snawder JE . J Oncol Pharm Pract 2015 22 (3) 396-408 OBJECTIVES: Contamination of workplace surfaces by antineoplastic drugs presents an exposure risk for healthcare workers. Traditional instrumental methods to detect contamination such as gas chromatography-mass spectrometry (GC-MS) or liquid chromatography-tandem mass spectrometry (LC-MS/MS) are sensitive and accurate but expensive and incapable of producing results in real time. This limits their utility in preventing worker exposure. We are currently developing monitors based on lateral flow immunoassay that can detect drug contamination in near real time. In this report, we describe the laboratory performance of a 5-fluorouracil (5-FU) monitor. METHODS: The monitor was evaluated by spiking ceramic, vinyl, composite, stainless steel, and glass surfaces of 100 cm2 area with 5-FU masses of 0, 5, 10, 25, 50, and 100 ng. The surface was sampled with a wetted cotton swab, the swab was extracted with buffer, and the resulting solution was applied to a lateral flow monitor. Two ways of evaluating the response of these monitors were used: an electronic method where a lateral flow reader was used for measuring line intensities, and a visual method where the intensity of the test line was visually compared to the control line. RESULTS: The 5-FU monitor is capable of detecting 10 ng/100 cm2 (0.1 ng/cm2) using the electronic reader and 25 ng/100 cm2 (0.25 ng/cm2) using the visual comparison method for the surfaces studied. The response of the monitors was compared to LC-MS/MS results for the same samples for validation and there was good correlation of the two methods but some differences in absolute response, especially at higher spiking levels for the surface samples. |
Detection and measurement of surface contamination by multiple antineoplastic drugs using multiplex bead assay
Smith JP , Sammons DL , Robertson SA , Pretty JR , DeBord DG , Connor TH , Snawder JE . J Oncol Pharm Pract 2014 22 (1) 60-7 OBJECTIVES: Contamination of workplace surfaces by antineoplastic drugs presents an exposure risk for healthcare workers. Traditional instrumental methods to detect contamination such as liquid chromatography-mass spectrometry/mass spectrometry (LC-MS/MS) are sensitive and accurate but expensive. Since immunochemical methods may be cheaper and faster than instrumental methods, we wanted to explore their use for routine drug residue detection for preventing worker exposure. METHODS: In this study we examined the feasibility of using fluorescence covalent microbead immunosorbent assay (FCMIA) for simultaneous detection and semi-quantitative measurement of three antineoplastic drugs (5-fluorouracil, paclitaxel, and doxorubicin). The concentration ranges for the assay were 0-1000 ng/ml for 5-fluorouracil, 0-100 ng/ml for paclitaxel, and 0-2 ng/ml for doxorubicin. The surface sampling technique involved wiping a loaded surface with a swab wetted with wash buffer, extracting the swab in storage/blocking buffer, and measuring drugs in the extract using FCMIA. RESULTS: There was no significant cross-reactivity between these drugs at the ranges studied indicated by a lack of response in the assay to cross analytes. The limit of detection (LOD) for 5-fluorouracil on the surface studied was 0.93 ng/cm2 with a limit of quantitation (LOQ) of 2.8 ng/cm2, the LOD for paclitaxel was 0.57 ng/cm2 with an LOQ of 2.06 ng/cm2, and the LOD for doxorubicin was 0.0036 ng/cm2 with an LOQ of 0.013 ng/cm2. CONCLUSION: The use of FCMIA with a simple sampling technique has potential for low cost simultaneous detection and semi-quantitative measurement of surface contamination from multiple antineoplastic drugs. |
Sampling and mass spectrometric analytical methods for five antineoplastic drugs in the healthcare environment
Pretty JR , Connor TH , Spasojevic I , Kurtz KS , McLaurin JL , B' Hymer C , Debord DG . J Oncol Pharm Pract 2010 18 (1) 23-36 CONTEXT: Healthcare worker exposure to antineoplastic drugs continues to be reported despite safe handling guidelines published by several groups. Sensitive sampling and analytical methods are needed so that occupational safety and health professionals may accurately assess environmental and biological exposure to these drugs in the workplace. OBJECTIVE: To develop liquid chromatography-mass spectrometry/mass spectrometry (LC-MS/MS) analytical methods for measuring five antineoplastic drugs in samples from the work environment, and to apply these methods in validating sampling methodology. A single method for quantifying several widely used agents would decrease the number of samples required for method development, lower cost, and time of analysis. Methods for measuring these drugs in workers' urine would also be useful in monitoring personal exposure levels. RESULTS: LC-MS/MS methods were developed for individual analysis of five antineoplastic drugs in wipe and air sample media projected for use in field sampling: cyclophosphamide, ifosfamide, paclitaxel, doxorubicin, and 5-fluorouracil. Cyclophosphamide, ifosfamide, and paclitaxel were also measured simultaneously in some stages of the work. Extraction methods for air and wipe samples were developed and tested using the aforementioned analytical methods. Good recoveries from the candidate air and wipe sample media for most of the compounds, and variable recoveries for test wipe samples depending on the surface under study, were observed. Alternate LC-MS/MS methods were also developed to detect cyclophosphamide and paclitaxel in urine samples. CONCLUSIONS: The sampling and analytical methods were suitable for determining worker exposure to antineoplastics via surface and breathing zone contamination in projected surveys of healthcare settings. |
Evaluation of antineoplastic drug exposure of health care workers at three university-based U.S. cancer centers
Connor TH , DeBord DG , Pretty JR , Oliver MS , Roth TS , Lees PS , Krieg EF Jr , Rogers B , Escalante CP , Toennis CA , Clark JC , Johnson BC , McDiarmid MA . J Occup Environ Med 2010 52 (10) 1019-27 OBJECTIVE: This study evaluated health care worker exposure to antineoplastic drugs. METHODS: A cross-sectional study examined environmental samples from pharmacy and nursing areas. A 6-week diary documented tasks involving those drugs. Urine was analyzed for two specific drugs, and blood samples were analyzed by the comet assay. RESULTS: Sixty-eight exposed and 53 nonexposed workers were studied. Exposed workers recorded 10,000 drug-handling events during the 6-week period. Sixty percent of wipe samples were positive for at least one of the five drugs measured. Cyclophosphamide was most commonly detected, followed by 5-fluorouracil. Three of the 68 urine samples were positive for one drug. No genetic damage was detected in exposed workers using the comet assay. CONCLUSIONS: Despite following recommended safe-handling practices, workplace contamination with antineoplastic drugs in pharmacy and nursing areas continues at these locations. |
- Page last reviewed:Feb 1, 2024
- Page last updated:Mar 21, 2025
- Content source:
- Powered by CDC PHGKB Infrastructure