Last data update: Dec 09, 2024. (Total: 48320 publications since 2009)
Records 1-7 (of 7 Records) |
Query Trace: Pickens CA[original query] |
---|
Multiplexing iduronate-2-sulphatase (MPS-II) into a 7-plex lysosomal storage disorder MS/MS assay using cold-induced phase separation
Courtney E , Pickens CA , Cuthbert C , Petritis K . Int J Neonatal Screen 2023 9 (2) Mucopolysaccharidosis type II (MPS-II, Hunter syndrome, OMIM:30990) is a lysosomal storage disorder (LSD) that results in iduronate 2-sulphatase (I2S) enzyme deficiency. MPS-II was added to the Recommended Uniform Screening Panel (RUSP) in August 2022; thus, there is an increased demand for multiplexing I2S into existing LSD screening assays. After incubation with LSD synthetic substrates, extracts are cleaned using liquid-liquid extraction with ethyl acetate or protein precipitation using acetonitrile (ACN). We investigated cold-induced water ACN phase separation (CIPS) to improve the combination of 6-plex and I2S extracts to create a 7-plex assay, and compared it to room temperature ACN and ethyl acetate liquid-liquid extraction. The extracts were dried and resuspended in the mobile phase, and then analyzed using an optimized 1.9 min injection-to-injection liquid chromatography method coupled with tandem mass spectrometry (LC-MS/MS). The combination of ACN and CIPS improved the detection for I2S products without significant detriment to other analytes, which is attributable to a more complete coagulation and separation of heme, proteins, and extracted residual salts. Using CIPS for sample cleanup in dried blood spots (DBS) appears to represent a promising and straightforward way of achieving cleaner sample extracts in a new 7-plex LSD screening panel. |
Harmonization of newborn screening results for Pompe disease and Mucopolysaccharidosis Type I
Dorley MC , Dizikes GJ , Pickens CA , Cuthbert C , Basheeruddin K , Gulamali-Majid F , Hetterich P , Hietala A , Kelsey A , Klug T , Lesko B , Mills M , Moloney S , Neogi P , Orsini J , Singer D , Petritis K . Int J Neonatal Screen 2023 9 (1) In newborn screening, false-negative results can be disastrous, leading to disability and death, while false-positive results contribute to parental anxiety and unnecessary follow-ups. Cutoffs are set conservatively to prevent missed cases for Pompe and MPS I, resulting in increased falsepositive results and lower positive predictive values. Harmonization has been proposed as a way to minimize false-negative and false-positive results and correct for method differences, so we harmonized enzyme activities for Pompe and MPS I across laboratories and testing methods (Tandem Mass Spectrometry (MS/MS) or Digital Microfluidics (DMF)). Participating states analyzed proofof- concept calibrators, blanks, and contrived specimens and reported enzyme activities, cutoffs, and other testing parameters to Tennessee. Regression and multiples of the median were used to harmonize the data. We observed varied cutoffs and results. Six of seven MS/MS labs reported enzyme activities for one specimen for MPS I marginally above their respective cutoffs with results classified as negative, whereas all DMF labs reported this specimen's enzyme activity below their respective cutoffs with results classified as positive. Reasonable agreement in enzyme activities and cutoffs was achieved with harmonization; however, harmonization does not change how a value would be reported as this is dependent on the placement of cutoffs. |
Multiplexing homocysteine into first-tier newborn screening mass spectrometry assays using selective thiol derivatization
Pickens CA , Courtney E , Isenberg SL , Cuthbert C , Petritis K . Clin Chem 2023 69 (5) 470-481 BACKGROUND: Classical homocystinuria (HCU) results from deficient cystathionine β-synthase activity, causing elevated levels of Met and homocysteine (Hcy). Newborn screening (NBS) aims to identify HCU in pre-symptomatic newborns by assessing Met concentrations in first-tier screening. However, unlike Hcy, Met testing leads to a high number of false-positive and -negative results. Therefore, screening for Hcy directly in first-tier screening would be a better biomarker for use in NBS. METHODS: Dried blood spot (DBS) quality control and residual clinical specimens were used in analyses. Several reducing and maleimide reagents were investigated to aid in quantification of total Hcy (tHcy). The assay which was developed and validated was performed by flow injection analysis-tandem mass spectrometry (FIA-MS/MS). RESULTS: Interferents of tHcy measurement were identified, so selective derivatization of Hcy was employed. Using N-ethylmaleimide (NEM) to selectively derivatize Hcy allowed interferent-free quantification of tHcy by FIA-MS/MS in first-tier NBS. The combination of tris(2-carboxyethyl)phosphine (TCEP) and NEM yielded significantly less matrix effects compared to dithiothreitol (DTT) and NEM. Analysis of clinical specimens demonstrated that the method could distinguish between HCU-positive, presumptive normal newborns, and newborns receiving total parenteral nutrition. CONCLUSIONS: Here we present the first known validated method capable of screening tHcy in DBS during FIA-MS/S first-tier NBS. |
Development of a universal second-tier newborn screening LC-MS/MS method for amino acids, lysophosphatidylcholines, and organic acids
Kilgore MB , Platis D , Lim T , Isenberg S , Pickens CA , Cuthbert C , Petritis K . Anal Chem 2023 95 (6) 3187-3194 First-tier MS-based newborn screening by flow injection analysis can have high presumptive positive rates, often due to isomeric/isobaric compounds or poor biomarker specificity. These presumptive positive samples can be analyzed by second-tier screening assays employing separations such as liquid chromatography-mass spectrometry (LC-MS/MS), which increases test specificity and drastically reduces false positive referrals. The ability to screen for multiple disorders in a single multiplexed test simplifies workflows and maximizes public health laboratories' resources. In this study, we developed and validated a highly multiplexed second-tier method for dried blood spots using a hydrophilic interaction liquid chromatography (HILIC) column coupled to an MS/MS system. The LC-MS/MS method was capable of simultaneously detecting second-tier biomarkers for maple syrup urine disease, homocystinuria, methylmalonic acidemia, propionic acidemia, glutaric acidemia type 1, glutaric acidemia type 2, guanidinoacetate methyltransferase deficiency, short-chain acyl-CoA dehydrogenase deficiency, adrenoleukodystrophy, and Pompe disease. |
Harmonizing newborn screening laboratory proficiency test results using the CDC NSQAP Reference Materials
Pickens CA , Sternberg M , Seeterlin M , De Jesús VR , Morrissey M , Manning A , Bhakta S , Held PK , Mei J , Cuthbert C , Petritis K . Int J Neonatal Screen 2020 6 (3) 75 Newborn screening (NBS) laboratories cannot accurately compare mass spectrometry-derived results and cutoff values due to differences in testing methodologies. The objective of this study was to assess harmonization of laboratory proficiency test (PT) results using quality control (QC) data. Newborn Screening Quality Assurance Program (NSQAP) QC and PT data reported from 302 laboratories in 2019 were used to compare results among laboratories. QC materials were provided as dried blood spot cards which included a base pool and the base pool enriched with specific concentrations of metabolites in a linear range. QC data reported by laboratories were regressed on QC data reported by the Centers for Disease Control and Prevention (CDC), and laboratory's regression parameters were used to harmonize their PT result. In general, harmonization tended to reduce overall variation in PT data across laboratories. The metabolites glutarylcarnitine (C5DC), tyrosine, and phenylalanine were displayed to highlight inter- and intra-method variability in NBS results. Several limitations were identified using retrospective data for harmonization, and future studies will address these limitations to further assess feasibility of using NSQAP QC data to harmonize PT data. Harmonizing NBS data using common QC materials appears promising to aid result comparison between laboratories. |
Development of dried blood spot quality control materials for adenosine deaminase severe combined immunodeficiency and an LC-MS/MS method for their characterization
Young B , Hendricks J , Foreman D , Pickens CA , Hovell C , De Jesus VR , Haynes C , Petritis K . Clin Mass Spectrom 2020 17 (4) 4-11 Adenosine deaminase severe combined immunodeficiency (ADA-SCID) is an autosomal recessive disorder in which a lack of ADA enzyme prevents the maturation of T- and B-cells; early intervention is crucial for restoring immune function in affected neonates. ADA is responsible for purine metabolism and—in its absence—adenosine, deoxyadenosine, and S-adenosylhomocysteine build up and can be detected in the blood. Preparing dried blood spot (DBS) quality control (QC) materials for these analytes is challenging because enrichments are quickly metabolized by the endogenous ADA in normal donor blood. Adding an inhibitor, erythro-9-(2-hydroxy-3-nonyl) adenine (EHNA), has been previously reported to minimize enzyme activity, although this adds additional cost and complexity. We describe an alternative method using unnatural L-enantiomer nucleosides (L-adenosine and L-2′-deoxyadenosine) which eliminates the need for enzyme inhibition. We also present a novel method for characterization of the materials using liquid chromatography mass spectrometry to quantify the analytes of interest. |
High resolution mass spectrometry newborn screening applications for quantitative analysis of amino acids and acylcarnitines from dried blood spots
Pickens CA , Petritis K . Anal Chim Acta 2020 1120 85-96 Amino acid and acylcarnitine first-tier newborn screening typically employs derivatized or non-derivatized sample preparation methods followed by FIA coupled to triple quadrupole (TQ) MS/MS. The low resolving power of TQ instruments results in difficulties distinguishing nominal isobaric metabolites, especially those with identical quantifying product ions such as malonylcarnitine (C3DC) and 4-hydroxybutylcarnitine (C4OH). Twenty-eight amino acids and acylcarnitines extracted from dried blood spots (DBS) were analyzed by direct injection (DI)-HRMS on a Q-Exactive Plus across available mass resolving powers in SIM, in PRM at 17,000 full width at half maximum (FWHM), and a developed SIM/PRM hybrid MS method. Most notably, quantitation of C3DC and C4OH was successful by HRMS in non-derivatized samples, thus, potentially eliminating sample derivatization requirements. Quantitation differed between SIM and PRM acquired data for several metabolites, and it was determined these quantitative differences were due to collision energy differences or kinetic isotope effects between the unlabeled metabolites and the corresponding labeled isotopologue internal standards. Overall quantitative data acquired by HRMS were similar to data acquired on TQ MS/MS platform. A proof-of-concept hybrid DI-HRMS and SIM/PRM/FullScan method was developed demonstrating the ability to hybridize targeted newborn screening with metabolomic screening. |
- Page last reviewed:Feb 1, 2024
- Page last updated:Dec 09, 2024
- Content source:
- Powered by CDC PHGKB Infrastructure