Last data update: Sep 30, 2024. (Total: 47785 publications since 2009)
Records 1-30 (of 42 Records) |
Query Trace: Park JH[original query] |
---|
Airborne bacteria in institutional and commercial buildings in Korea: Characterization with 16S rRNA gene sequencing and association with environmental conditions
Kim YJ , Lee BG , Shim JE , Lee H , Park JH , Yeo MK . Aerosol Sci Technol 2024 Information on microorganisms in indoor air of various institutional and commercial buildings has significant value in a public health management perspective. However, there is a lack of prior research comparing indoor airborne microbiota across different categories of those buildings. We characterized indoor airborne bacteria in 10 buildings (two for each of five categories: train station, parking garage, mart, public library, and daycare center) during summer and winter. The 16S rRNA gene in the bacterial gDNA extracted from samples was quantified using quantitative real-time polymerase chain reaction and sequenced with the Illumina MiSeq™ platform for characterizing community composition. We collected information on temperature, relative humidity, CO2 concentration, and particulate matter (PM) concentrations by particle size (<1 µm, 1–2.5 µm, 2.5–10 µm) indoors. We performed a multivariate regression analysis to identify factors influencing bacterial quantity and Permutational Multivariate Analysis of Variance (PERMANOVA) to determine factors affecting cluster dissimilarity. We found that bacterial concentration was significantly (p-values < 0.05) associated with season and CO2 concentration. The PERMANOVA analyses showed the significant (p-values < 0.05) associations of bacterial cluster dissimilarity with season, building category, and CO2. Our study indicated that the season, and CO2 concentrations may be important factors associated with the indoor airborne bacterial concentration and composition. Building category and usage appeared to significantly influence the bacterial community composition but not the concentration. Our study may provide basic data on bacterial community composition and their concentration that are needed for properly managing microbial exposures in occupants or customers of the studied institutional and commercial buildings. Copyright © 2024 American Association for Aerosol Research. © 2024 American Association for Aerosol Research. |
Optimization of Aspergillus versicolor culture and aerosolization in a murine model of inhalational fungal exposure
Blackwood CB , Croston TL , Barnes MA , Lemons AR , Rush RE , Goldsmith T , McKinney WG , Anderson S , Weaver KL , Sulyok M , Park JH , Germolec D , Beezhold DH , Green B . J Fungi (Basel) 2023 9 (11) Aspergillus versicolor is ubiquitous in the environment and is particularly abundant in damp indoor spaces. Exposure to Aspergillus species, as well as other environmental fungi, has been linked to respiratory health outcomes, including asthma, allergy, and even local or disseminated infection. However, the pulmonary immunological mechanisms associated with repeated exposure to A. versicolor have remained relatively uncharacterized. Here, A. versicolor was cultured and desiccated on rice then placed in an acoustical generator system to achieve aerosolization. Mice were challenged with titrated doses of aerosolized conidia to examine deposition, lymphoproliferative properties, and immunotoxicological response to repeated inhalation exposures. The necessary dose to induce lymphoproliferation was identified, but not infection-like pathology. Further, it was determined that the dose was able to initiate localized immune responses. The data presented in this study demonstrate an optimized and reproducible method for delivering A. versicolor conidia to rodents via nose-only inhalation. Additionally, the feasibility of a long-term repeated exposure study was established. This experimental protocol can be used in future studies to investigate the physiological effects of repeated pulmonary exposure to fungal conidia utilizing a practical and relevant mode of delivery. In total, these data constitute an important foundation for subsequent research in the field. |
Adjustment of matrix effects in analysis of 36 secondary metabolites of microbial and plant origin in indoor floor dust using liquid chromatography-tandem mass spectrometry
Rimayi C , Park JH . Buildings 2023 13 (5) Exposure to microbial agents in water-damaged buildings is a major public health concern. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) has become a primary tool for testing environmental samples for microbial secondary metabolites (SMs); however, matrix effects can lead to inaccurate results in exposure assessment. Applying a universal internal standard (ISTD) and a matrix-matched calibration can adjust for matrix effects, as shown by our previous study. However, there are only few isotope-labeled internal standards for SMs available on the market. In this study, we determined the best-performing ISTDs among ten candidates (nine 13C-labeled isotopes and one unlabeled analogue) for each of 36 SMs. We analyzed school floor dust spiked with the 36 SMs to identify the best-performing ISTDs (initial experiment) and examined reproducibility with the selected ISTDs and the same spiked dust (validation 1). We also tested applicability for the selected ISTDs using spiked dust collected from different schools (validation 2). The three experiments showed that 26, 17, and 19 SMs had recoveries within the range 100 ± 40%. 13C-ochratoxin A and 13C-citrinin were most frequently selected as the best ISTDs for the 36 SMs, followed by deepoxy-deoxynivalenol, 13C-sterigmatocystin, and 13C-deoxynivalenol. Our study shows that using the identified, best-performing analogous ISTDs for those metabolites may improve testing accuracy for indoor dust and help better estimate exposure effects on potential health. © 2023 by the authors. |
Development of air purifier operation guidelines using grey box models for the concentrations of particulate matter in elementary school classrooms
Park S , Song D , Jo YM , Park JH , Lee TJ , Koo J . Aerosol Sci Tech 2023 57 (5) 467-485 Considering the hazardous effects of particulate matter (PM) exposure on students and teachers and the high PM concentration issue in South Korea, air purifiers have recently been installed in most classrooms to improve air quality. However, some on-site challenges, such as operational costs and noise, have been issues with the continuous operation of air purifiers. Therefore, a guideline is needed to dynamically predict the indoor PM concentration based on the changes in outdoor PM concentration and activate the air purifiers only when necessary. This study develops a grey-box model that uses measured data and physical differential equations to perform the given objective and verifies its accuracy using ASTM D5157. Modeling and analysis results have obtained information that can form the basis for developing guidelines to address PM issues in schools: The air purifier should be operated during periods where the predicted values exceed the limit in closed windows and the air purifier is not operating. It was also confirmed that the need for the operation of the air purifier varies between schools and classrooms under the same outdoor PM concentration. Indoor PM concentration increased significantly after students' simultaneous mass movement, necessitating air purifiers' operation before and after the events. The pre-filter of the heater also aided in the removal of coarse PM. Additionally, the limitations and future development directions of the model were discussed. |
Airborne fungal and bacterial microbiome in classrooms of elementary schools during the COVID-19 pandemic period: Effects of school disinfection and other environmental factors.
Yang JIL , Lee BG , Park JH , Yeo MK . Indoor Air 2022 32 (9) e13107 The aim of the study was to examine the effects of environmental factors including disinfection on airborne microbiome during the coronavirus disease 2019 pandemic, we evaluated indoor and outdoor air collected from 19 classrooms regularly disinfected. Extracted bacterial and fungal DNA samples were sequenced using the Illumina MiSeq platform. Using bacterial DNA copy number concentrations from qPCR analysis, multiple linear regressions including environmental factors as predictors were performed. Microbial diversity and community composition were evaluated. Classrooms disinfected with spray 1week before sampling had lower bacterial DNA concentration (3116 DNA copies/m(3) ) than those >1week (5003 copies/m(3) ) (p-values=0.06). The bacterial DNA copy number concentration increased with temperature and was higher in classrooms in coastal than inland cities (p-values <0.01). Bacterial diversity in outdoor air was higher in coastal than inland cities while outdoor fungal diversity was higher in inland than coastal cities. These outdoor microbiomes affected classroom microbial diversity but bacterial community composition at the genus level in occupied classrooms were similar between coastal and inland cities. Our findings emphasize that environmental conditions including disinfection, climate, and school location are important factors in shaping classroom microbiota. Yet, further research is needed to understand the effects of modified microbiome by disinfection on occupants' health. |
Direct-reading instruments for aerosols: A review for occupational health and safety professionals part 1: Instruments and good practices
Vosburgh DJH , Cauda E , O'Shaughnessy PT , Sheehan MJ , Park JH , Anderson K . J Occup Environ Hyg 2022 19 (12) 1-16 With advances in technology, there are an increasing number of direct-reading instruments available to occupational health and safety professionals to evaluate occupational aerosol exposures. Despite the wide array of direct-reading instruments available to professionals, adoption of direct-reading technology to monitor workplace exposures has been limited, partly due to a lack of knowledge on how the instruments operate, how to select an appropriate instrument, and challenges in data analysis techniques. This paper presents a review of direct-reading aerosol instruments available to occupational health and safety professionals, describes the principles of operation, provides guidance on instrument selection based on the workplace and exposure, and discusses data analysis techniques in an effort to overcome these barriers to adoption. This paper does not cover all direct-reading instruments for aerosols but only those that an occupational health and safety professional could use in a workplace to evaluate exposures. Therefore, this paper focuses on instruments that have the most potential for workplace use due to their robustness, past workplace use, and price with regards to return on investment. The instruments covered in this paper include those that measure aerosol number concentration, mass concentration and aerosol size distributions. |
NIOSH Dampness and Mold Assessment Tool (DMAT): Documentation and data analysis of dampness and mold-related damage in buildings and its application
Park JH , Cox-Ganser JM . Buildings 2022 12 (8) 1075-1092 Indoor dampness and mold are prevalent, and the exposure has been associated with various illnesses such as the exacerbation of existing asthma, asthma development, current asthma, ever-diagnosed asthma, bronchitis, respiratory infection, allergic rhinitis, dyspnea, wheezing, cough, upper respiratory symptoms, and eczema. However, assessing exposures or environments in damp and moldy buildings/rooms, especially by collecting and analyzing environmental samples for microbial agents, is complicated. Nonetheless, observational assessment (visual and olfactory inspection) has been demonstrated as an effective method for evaluating indoor dampness and mold. The National Institute for Occupational Safety and Health developed an observational assessment method called the Dampness and Mold Assessment Tool (DMAT). The DMAT uses a semi-quantitative approach to score the level of dampness and mold-related damage (mold odor, water damage/stains, visible mold, and wetness/dampness) by intensity or size for each of the room components (ceiling, walls, windows, floor, furnishings, ventilation system, pipes, and supplies and materials). Total or average room scores and factor-or component-specific scores can be calculated for data analysis. Because the DMAT uses a semi-quantitative scoring method, it better differentiates the level of damage compared to the binary (presence or absence of damage) approach. Thus, our DMAT provides useful information on identifying dampness and mold, tracking and comparing past and present damage by the scores, and prioritizing remediation to avoid potential adverse health effects in occupants. This protocol-type article describes the DMAT and demonstrates how to apply it to effectively manage indoor dampness and mold-related damage. © 2022 by the authors. |
Mycobiota and the contribution of yeasts in floor dust of 50 elementary schools characterized with sequencing internal transcribed spacer region of ribosomal DNA
Park JH , Lemons AR , Croston TL , Park Y , Roseman J , Green BJ , Cox-Ganser JM . Environ Sci Technol 2022 56 (16) 11493-11503 The assemblage of fungi including unicellular yeasts in schools is understudied. We conducted an environmental study to characterize fungal communities in classroom floor dust. We collected 500 samples from 50 elementary schools in Philadelphia, PA, and evaluated room dampness/mold conditions. Genomic DNA from dust was extracted for internal transcribed spacer 1 Illumina MiSeq sequencing to identify operational taxonomic units (OTUs) organized from DNA sequences. Differential abundance analyses were performed to examine significant differences in abundance among groups. We identified 724 genera from 1490 OTUs. The genus Epicoccum was not diverse but the most abundant (relative abundance = 18.9%). Fungi were less diverse but most dissimilar in composition in the most water-damaged classrooms compared to the least water-damaged, indicating differential effects of individual classroom water-damage on fungal compositions. We identified 62 yeast genera, representing 19.6% of DNA sequences. Cyberlindnera was the most abundant (6.1%), followed by Cryptococcus, Aureobasidium, Rhodotorula, and Candida. The average relative abundance of yeasts tended to increase with increasing dampness and mold score and was significantly (p-value = 0.048) higher in the most water-damaged classrooms (22.4%) than the least water-damaged classrooms (18.2%). Our study suggests the need for further research on the potential health effects associated with exposures to yeasts in schools. |
Associations of emergency department visits for asthma with precipitation and temperature on thunderstorm days: A time-series analysis of data from Louisiana, USA, 2010-2012
Park JH , Lee E , Fechter-Leggett ED , Williams E , Yadav S , Bakshi A , Ebelt S , Bell JE , Strosnider H , Chew GL . Environ Health Perspect 2022 130 (8) 87003 BACKGROUND: Studies of thunderstorm asthma to understand risk factors using high-resolution climate data and asthma outcomes on a large scale are scarce. Moreover, thunderstorm asthma is not well studied in the United States. OBJECTIVES: We examined whether climate parameters involved in thunderstorms are associated with emergency department (ED) visits for acute asthma attacks in the United States. METHODS: We analyzed 63,789 asthma-related, daily ED visits for all age groups, and thunderstorm-associated climate data in Louisiana during 2010 through 2012. We performed time-series analyses using quasi-Poisson regression models with natural cubic splines of date, parish, holiday, day of week, season, daily maximum concentrations of ozone (O3) and fine particulate matter [PM 2.5 m in aerodynamic diameter (PM2.5)], and daily mean pressure, precipitation, and temperature. Because of a significant interaction effect between temperature and lightning days on asthma-related visits, we performed stratified analyses by days with/without lightning or thunderstorm (defined by any lightning and precipitation). RESULTS: On thunderstorm days, higher asthma-related ED visits were associated with higher daily mean precipitation [relative risk(RR) =1.145per1g/m2/s (95% CI: 1.009, 1.300)] and lower daily mean temperature [RR =1.011 per 1C change (1.000-1.021)] without carry-over effect to the next non-thunderstorm day. These higher risks were found mainly among children and adults <65years of age. We observed similar results on lightning days. However, we did not find similar associations for non-thunderstorm or non-lightning days. Daily maximum O3 and PM2.5 levels were not significantly associated with asthma ED visits on thunderstorm days. DISCUSSION: Higher precipitation and lower temperature on thunderstorm days appear to contribute to asthma attacks among people with asthma, suggesting they should consider taking precautions during thunderstorms. EDs should consider preparing for a potential increase of asthma-related visits and ensuring sufficient stock of emergency medication and supplies for forecasted severe thunderstorm days. https://doi.org/10.1289/EHP10440. |
Open database for international and national indoor environmental quality guidelines
Toyinbo O , Hägerhed L , Dimitroulopoulou S , Dudzinska M , Emmerich S , Hemming D , Park JH , Haverinen-Shaughnessy U . Indoor Air 2022 32 (4) e13028 The United Nations has mandated clean air as a human right.1 In addition, many influential international and national organizations have declared the right to a healthy environment.2 There is growing evidence that projected climate change has the potential to significantly affect public health directly or indirectly. Developing effective mitigation policies for residential and non-residential environments requires a better understanding of how parameters that affect indoor environmental quality (IEQ) (i.e., indoor air quality, ventilation, thermal comfort, noise, and lighting) interact, and how current and emerging trends in building construction, materials, infrastructure design, and use may affect these IEQ parameters and hence our health and wellbeing.3, 4 In this context, developing IEQ guidelines and setting standards are at the very core of defining and providing clean and healthy indoor environments. |
Side-by-side comparison of parent vs. technician-collected respiratory swabs in low-income, multilingual, urban communities in the United States.
Chaves SS , Park JH , Prill MM , Whitaker B , Park R , Chew GL . BMC Public Health 2022 22 (1) 103 BACKGROUND: Home-based swabbing has not been widely used. The objective of this analysis was to compare respiratory swabs collected by mothers of 7-12-year-olds living in low-income, multilingual communities in the United States with technician collected swabs. METHODS: Retrospective data analysis of respiratory samples collected at home by mothers compared to technicians. Anterior nasal and throat specimens collected using flocked swabs were combined in dry tubes. Test was done using TaqMan array cards for viral and bacterial pathogens. Cycle threshold (Ct) values of ribonuclease P (RNP) gene were used to assess specimen quality. Ct < 40 was interpreted as a positive result. Concordance of pathogen yield from mother versus technician collected swabs were analyzed using Cohen's Kappa coefficients. Correlation analysis, paired t-test, and Wilcoxon signed-rank test for paired samples were used for RNP Ct values. RESULTS: We enrolled 36 households in Cincinnati (African American) and 44 (predominately Chinese or Latino) in Boston. In Cincinnati, eight of 32 (25%) mothers did not finish high school, and 11 (34%) had finished high school only. In Boston, 13 of 44 (30%) mothers had less than a high school diploma, 23 (52%) had finished high school only. Mother versus technician paired swabs (n = 62) had similar pathogen yield (paired t-test and Wilcoxon signed rank test p-values = 0.62 and 0.63, respectively; 95% confidence interval of the difference between the two measurements = - 0.45-0.75). Median Ct value for RNP was 22.6 (interquartile range, IQR = 2.04) for mother-collected and 22.4 (IQR = 2.39) for technician-collected swabs (p = 0.62). Agreement on pathogen yield between samples collected by mothers vs. technicians was higher for viruses than for bacterial pathogens, with high concordance for rhinovirus/enterovirus, human metapneumovirus, and adenovirus (Cohen's kappa coefficients ≥80%, p < 0.0001). For bacterial pathogens, concordance was lower to moderate, except for Chlamydia pneumoniae, for which kappa coefficient indicated perfect agreement. CONCLUSION: Mothers with a range of education levels from low-income communities were able to swab their children equally well as technicians. Home-swabbing using dry tubes, and less invasive collection procedures, could enhance respiratory disease surveillance. |
Occupational Histoplasmosis: Epidemiology and Prevention Measures
de Perio MA , Benedict K , Williams SL , Niemeier-Walsh C , Green BJ , Coffey C , Di Giuseppe M , Toda M , Park JH , Bailey RL , Nett RJ . J Fungi (Basel) 2021 7 (7) In areas where Histoplasma is endemic in the environment, occupations involving activities exposing workers to soil that contains bird or bat droppings may pose a risk for histoplasmosis. Occupational exposures are frequently implicated in histoplasmosis outbreaks. In this paper, we review the literature on occupationally acquired histoplasmosis. We describe the epidemiology, occupational risk factors, and prevention measures according to the hierarchy of controls. |
Investigation of bacterial and fungal communities in indoor and outdoor air of elementary school classrooms by 16S rRNA gene and ITS region sequencing.
Lee BG , Yang JI , Kim E , Geum SW , Park JH , Yeo MK . Indoor Air 2021 31 (5) 1553-1562 The advent of high-throughput sequencing methods allowed researchers to fully characterize microbial community in environmental samples, which is crucial to better understand their health effects upon exposures. In our study, we investigated bacterial and fungal community in indoor and outdoor air of nine classrooms in three elementary schools in Seoul, Korea. The extracted bacterial 16S rRNA gene and fungal ITS regions were sequenced, and their taxa were identified. Quantitative polymerase chain reaction for total bacteria DNA was also performed. The bacterial community was richer in outdoor air than classroom air, whereas fungal diversity was similar indoors and outdoors. Bacteria such as Enhydrobacter, Micrococcus, and Staphylococcus that are generally found in human skin, mucous membrane, and intestine were found in great abundance. For fungi, Cladosporium, Clitocybe, and Daedaleopsis were the most abundant genera in classroom air and mostly related to outdoor plants. Bacterial community composition in classroom air was similar among all classrooms but differed from that in outdoor air. However, indoor and outdoor fungal community compositions were similar for the same school but different among schools. Our study indicated the main source of airborne bacteria in classrooms was likely human occupants; however, classroom airborne fungi most likely originated from outdoors. |
Bacterial community assemblages in classroom floor dust of 50 public schools in a large city: characterization using 16S rRNA sequences and associations with environmental factors.
Park JH , Lemons AR , Roseman J , Green BJ , Cox-Ganser JM . Microbiome 2021 9 (1) 15 Characterizing indoor microbial communities using molecular methods provides insight into bacterial assemblages present in environments that can influence occupants' health. We conducted an environmental assessment as part of an epidemiologic study of 50 elementary schools in a large city in the northeastern USA. We vacuumed dust from the edges of the floor in 500 classrooms accounting for 499 processed dust aliquots for 16S Illumina MiSeq sequencing to characterize bacterial assemblages. DNA sequences were organized into operational taxonomic units (OTUs) and identified using a database derived from the National Center for Biotechnology Information. Bacterial diversity and ecological analyses were performed at the genus level. We identified 29 phyla, 57 classes, 148 orders, 320 families, 1193 genera, and 2045 species in 3073 OTUs. The number of genera per school ranged from 470 to 705. The phylum Proteobacteria was richest of all while Firmicutes was most abundant. The most abundant order included Lactobacillales, Spirulinales, and Clostridiales. Halospirulina was the most abundant genus, which has never been reported from any school studies before. Gram-negative bacteria were more abundant and richer (relative abundance = 0.53; 1632 OTUs) than gram-positive bacteria (0.47; 1441). Outdoor environment-associated genera were identified in greater abundance in the classrooms, in contrast to homes where human-associated bacteria are typically more abundant. Effects of school location, degree of water damage, building condition, number of students, air temperature and humidity, floor material, and classroom's floor level on the bacterial richness or community composition were statistically significant but subtle, indicating relative stability of classroom microbiome from environmental stress. Our study indicates that classroom floor dust had a characteristic bacterial community that is different from typical house dust represented by more gram-positive and human-associated bacteria. Health implications of exposure to the microbiomes in classroom floor dust may be different from those in homes for school staff and students. Video abstract. |
Biological effects of inhaled hydraulic fracturing sand dust. IX. Summary and significance
Anderson SE , Barger M , Batchelor TP , Bowers LN , Coyle J , Cumpston A , Cumpston JL , Cumpston JB , Dey RD , Dozier AK , Fedan JS , Friend S , Hubbs AF , Jackson M , Jefferson A , Joseph P , Kan H , Kashon ML , Knepp AK , Kodali V , Krajnak K , Leonard SS , Lin G , Long C , Lukomska E , Marrocco A , Marshall N , Mc Kinney W , Morris AM , Olgun NS , Park JH , Reynolds JS , Roberts JR , Russ KA , Sager TM , Shane H , Snawder JE , Sriram K , Thompson JA , Umbright CM , Waugh S , Zheng W . Toxicol Appl Pharmacol 2020 409 115330 An investigation into the potential toxicological effects of fracking sand dust (FSD), collected from unconventional gas drilling sites, has been undertaken, along with characterization of their chemical and biophysical properties. Using intratracheal instillation of nine FSDs in rats and a whole body 4-d inhalation model for one of the FSDs, i.e., FSD 8, and related in vivo and in vitro experiments, the effects of nine FSDs on the respiratory, cardiovascular and immune systems, brain and blood were reported in the preceding eight tandem papers. Here, a summary is given of the key observations made in the organ systems reported in the individual studies. The major finding that inhaled FSD 8 elicits responses in extra-pulmonary organ systems is unexpected, as is the observation that the pulmonary effects of inhaled FSD 8 are attenuated relative to forms of crystalline silica more frequently used in animal studies, i.e., MIN-U-SIL®. An attempt is made to understand the basis for the extra-pulmonary toxicity and comparatively attenuated pulmonary toxicity of FSD 8. |
Biological effects of inhaled hydraulic fracturing sand dust. II. Particle characterization and pulmonary effects 30 d following intratracheal instillation
Fedan JS , Hubbs AF , Barger M , Schwegler-Berry D , Friend SA , Leonard SS , Thompson JA , Jackson MC , Snawder JE , Dozier AK , Coyle J , Kashon ML , Park JH , McKinney W , Roberts JR . Toxicol Appl Pharmacol 2020 409 115282 Hydraulic fracturing ("fracking") is used in unconventional gas drilling to allow for the free flow of natural gas from rock. Sand in fracking fluid is pumped into the well bore under high pressure to enter and stabilize fissures in the rock. In the process of manipulating the sand on site, respirable dust (fracking sand dust, FSD) is generated. Inhalation of FSD is a potential hazard to workers inasmuch as respirable crystalline silica causes silicosis, and levels of FSD at drilling work sites have exceeded occupational exposure limits set by OSHA. In the absence of any information about its potential toxicity, a comprehensive rat animal model was designed to investigate the bioactivities of several FSDs in comparison to MIN-U-SIL® 5, a respirable α-quartz reference dust used in previous animal models of silicosis, in several organ systems (Fedan, J.S., Toxicol Appl Pharmacol. 00, 000-000, 2020). The present report, part of the larger investigation, describes: 1) a comparison of the physico-chemical properties of nine FSDs, collected at drilling sites, and MIN-U-SIL® 5, a reference silica dust, and 2) a comparison of the pulmonary inflammatory responses to intratracheal instillation of the nine FSDs and MIN-U-SIL® 5. Our findings indicate that, in many respects, the physico-chemical characteristics, and the biological effects of the FSDs and MIN-U-SIL® 5 after intratracheal instillation, have distinct differences. |
Evidence for environmental-human microbiota transfer at a manufacturing facility with novel work-related respiratory disease
Wu BG , Kapoor B , Cummings KJ , Stanton ML , Nett RJ , Kreiss K , Abraham JL , Colby TV , Franko AD , Green FHY , Sanyal S , Clemente JC , Gao Z , Coffre M , Meyn P , Heguy A , Li Y , Sulaiman I , Borbet TC , Koralov SB , Tallaksen RJ , Wendland D , Bachelder VD , Boylstein RJ , Park JH , Cox-Ganser JM , Virji MA , Crawford JA , Edwards NT , Veillette M , Duchaine C , Warren K , Lundeen S , Blaser MJ , Segal LN . Am J Respir Crit Care Med 2020 202 (12) 1678-1688 INTRODUCTION: Workers' exposure to metalworking fluid (MWF) has been associated with respiratory disease. As part of a public health investigation of a manufacturing facility, we performed paired environmental and human sampling to evaluate cross-pollination of microbes between environment and host and possible effects on lung pathology present among workers. METHODS: Workplace environmental microbiota was evaluated in air and MWF samples. Human microbiota was evaluated in lung tissue samples from workers with respiratory symptoms found to have lymphocytic bronchiolitis and alveolar ductitis with B-cell follicles and emphysema, lung tissue controls, and in skin, nasal and oral samples from 302 workers from different areas of the facility. In vitro effects of MWF exposure on murine B-cells were assessed. RESULTS: Increased similarity of microbial composition was found between MWF samples and lung tissue samples of case workers compared to controls. Among workers in different locations within the facility, those that worked in machine shop area had skin, nasal and oral microbiota more closely related to the microbiota present in MWF samples. Lung samples from four index cases, and skin and nasal samples from workers in machine shop area were enriched with Pseudomonas, the dominant taxa in MWF. Exposure to used MWF stimulated murine B-cell proliferation in vitro, a hallmark cell subtype found in pathology of index cases. CONCLUSIONS: Evaluation of a manufacturing facility with a cluster of workers with respiratory disease supports cross-pollination of microbes from MWF to humans and suggests the potential for exposure to these microbes to be a health hazard. |
Effect of storage temperature and duration on concentrations of 27 fungal secondary metabolites spiked into floor dust from an office building
Jaderson M , Park JH . J Occup Environ Hyg 2020 17 (5) 1-11 Fungi are ubiquitous in environments and produce secondary metabolites that are usually low-molecular-weight organic compounds during growth processes. Dust samples containing these fungal secondary metabolites collected from study sites are often stored in certain temperature conditions for an extended period until laboratory analysis resources are available. However, there is little information on how stable fungal secondary metabolites are over time at different storage temperatures. We examined the stability of 27 fungal secondary metabolites spiked into floor dust samples collected from a moisture-damaged office building. Ninety-five dust aliquots were made from the spiked dust; five replicates were randomly assigned to a baseline (time = 0) and each of the 18 combinations of three temperatures (room temperature, 4 degrees C, or -80 degrees C) and six time points (2, 12, 25, 56, 79, and 105 weeks). At the baseline and each subsequent time point, we extracted and analyzed the fungal secondary metabolites from the spiked dust using ultra-performance liquid chromatograph-tandem mass spectrometer. To estimate change in concentration over storage time at each temperature condition, we applied multiple linear regression models with interaction effect between storage temperature and duration. For 10 of the 27 fungal secondary metabolites, the effect of time was significantly (p-values <0.05) or marginally (p-values <0.1) modified by temperature, but not for the remaining 17 metabolites. Generally, for most fungal secondary metabolites, storage at room temperature was significantly (p-values <0.05) associated with a larger decline in concentration (up to 83% for 3-nitropropionic acid at about 11 months) than storing at 4 degrees C (up to 55% for emodin) or -80 degrees C (55% for asperglaucide). We did not observe significant differences between storage at 4 degrees C, or -80 degrees C. Storage temperature influenced degradation of fungal secondary metabolites more than storage time. Our study indicates that fungal secondary metabolites, including mycotoxins in floor dust, quickly degrade at room temperature. However, storing dust samples at 4 degrees C might be adequate given that storing them at -80 degrees C did not further reduce degradation of fungal secondary metabolites. |
Work-related adverse respiratory health outcomes at a machine manufacturing facility with a cluster of bronchiolitis, alveolar ductitis and emphysema (BADE)
Cummings KJ , Stanton ML , Kreiss K , Boylstein RJ , Park JH , Cox-Ganser JM , Virji MA , Edwards NT , Segal LN , Blaser MJ , Weissman DN , Nett RJ . Occup Environ Med 2020 77 (6) 386-392 OBJECTIVES: Four machine manufacturing facility workers had a novel occupational lung disease of uncertain aetiology characterised by lymphocytic bronchiolitis, alveolar ductitis and emphysema (BADE). We aimed to evaluate current workers' respiratory health in relation to job category and relative exposure to endotoxin, which is aerosolised from in-use metalworking fluid. METHODS: We offered a questionnaire and spirometry at baseline and 3.5 year follow-up. Endotoxin exposures were quantified for 16 production and non-production job groups. Forced expiratory volume in one second (FEV1) decline >/=10% was considered excessive. We examined SMRs compared with US adults, adjusted prevalence ratios (aPRs) for health outcomes by endotoxin exposure tertiles and predictors of excessive FEV1 decline. RESULTS: Among 388 (89%) baseline participants, SMRs were elevated for wheeze (2.5 (95% CI 2.1 to 3.0)), but not obstruction (0.5 (95% CI 0.3 to 1.1)). Mean endotoxin exposures (range: 0.09-28.4 EU/m(3)) were highest for machine shop jobs. Higher exposure was associated with exertional dyspnea (aPR=2.8 (95% CI 1.4 to 5.7)), but not lung function. Of 250 (64%) follow-up participants, 11 (4%) had excessive FEV1 decline (range: 403-2074 mL); 10 worked in production. Wheeze (aPR=3.6 (95% CI 1.1 to 12.1)) and medium (1.3-7.5 EU/m(3)) endotoxin exposure (aPR=10.5 (95% CI 1.3 to 83.1)) at baseline were associated with excessive decline. One production worker with excessive decline had BADE on subsequent lung biopsy. CONCLUSIONS: Lung function loss and BADE were associated with production work. Relationships with relative endotoxin exposure indicate work-related adverse respiratory health outcomes beyond the sentinel disease cluster, including an incident BADE case. Until causative factors and effective preventive strategies for BADE are determined, exposure minimisation and medical surveillance of affected workforces are recommended. |
Cultivation and aerosolization of Stachybotrys chartarum for modeling pulmonary inhalation exposure
Lemons AR , Croston TL , Goldsmith WT , Barnes MA , Jaderson MA , Park JH , McKinney W , Beezhold DH , Green BJ . Inhal Toxicol 2019 31 1-11 Objective: Stachybotrys chartarum is a hydrophilic fungal species commonly found as a contaminant in water-damaged building materials. Although several studies have suggested that S. chartarum exposure elicits a variety of adverse health effects, the ability to characterize the pulmonary immune responses to exposure is limited by delivery methods that do not replicate environmental exposure. This study aimed to develop a method of S. chartarum aerosolization to better model inhalation exposures. Materials and methods: An acoustical generator system (AGS) was previously developed and utilized to aerosolize and deliver fungal spores to mice housed in a multi-animal nose-only exposure chamber. In this study, methods for cultivating, heat-inactivating, and aerosolizing two macrocyclic trichothecene-producing strains of S. chartartum using the AGS are described. Results and discussion: In addition to conidia, acoustical generation of one strain of S. chartarum resulted in the aerosolization of fungal fragments (<2 microm aerodynamic diameter) derived from conidia, phialides, and hyphae that initially comprised 50% of the total fungal particle count but was reduced to less than 10% over the duration of aerosolization. Acoustical generation of heat-inactivated S. chartarum did not result in a similar level of fragmentation. Delivery of dry, unextracted S. chartarum using these aerosolization methods resulted in pulmonary inflammation and immune cell infiltration in mice inhaling viable, but not heat-inactivated S. chartarum. Conclusions: These methods of S. chartarum growth and aerosolization allow for the delivery of fungal bioaerosols to rodents that may better simulate natural exposure within water-damaged indoor environments. |
Effects of air cleaners and school characteristics on classroom concentrations of particulate matter in 34 elementary schools in Korea
Park JH , Lee TJ , Park MJ , Oh HN , Jo YM . Build Environ 2020 167 Exposure to particulate matter (PM) in school environments has been associated with respiratory illnesses among children. Although using air cleaners was reported to reduce PM exposure and improve residents' health in homes, their effects in classrooms are not well understood. We examined how the use of air cleaners in classrooms and school/classroom characteristics affect the levels of indoor PM. Our environmental study included 102 classrooms from 34 elementary schools located on the mainland peninsula and an island in Korea. Indoor and outdoor PM were monitored simultaneously with portable aerosol spectrometers, and indoor gravimetric PM levels were measured with low volume, size-selective samplers during the class hours. Correlations among PM measurements were computed and final multiple regression models for indoor PM were constructed with a model building procedure. Correlation between indoor and outdoor PM2.5 (PM < 2.5 μm in aerodynamic diameter) was higher (r = 0.78, p < 0.01) than that of PM10 (PM < 10 μm) (r = 0.49, p < 0.01). School location, classroom occupant density, and ambient PM levels significantly (p-values<0.05) affected classroom PM concentrations. The adjusted PM levels in classrooms using air cleaners were significantly (p-values<0.01) lower by approximately 35% than in classrooms not using them. However, air cleaners appeared to remove PM2.5 more effectively than PM10, perhaps because coarse particles settle more rapidly than fine particles on surfaces, or their resuspension and generation rate by occupants exceeds the removal rate by air cleaners. Our study suggests that routine cleaning to remove surface dust along with the use of air cleaners might be required to effectively reduce occupants’ exposure in classrooms. |
Severe lung disease characterized by lymphocytic bronchiolitis, alveolar ductitis, and emphysema (BADE) in industrial machine-manufacturing workers
Cummings KJ , Stanton ML , Nett RJ , Segal LN , Kreiss K , Abraham JL , Colby TV , Franko AD , Green FHY , Sanyal S , Tallaksen RJ , Wendland D , Bachelder VD , Boylstein RJ , Park JH , Cox-Ganser JM , Virji MA , Crawford JA , Green BJ , LeBouf RF , Blaser MJ , Weissman DN . Am J Ind Med 2019 62 (11) 927-937 BACKGROUND: A cluster of severe lung disease occurred at a manufacturing facility making industrial machines. We aimed to describe disease features and workplace exposures. METHODS: Clinical, functional, radiologic, and histopathologic features were characterized. Airborne concentrations of thoracic aerosol, metalworking fluid, endotoxin, metals, and volatile organic compounds were measured. Facility airflow was assessed using tracer gas. Process fluids were examined using culture, polymerase chain reaction, and 16S ribosomal RNA sequencing. RESULTS: Five previously healthy male never-smokers, ages 27 to 50, developed chest symptoms from 1995 to 2012 while working in the facility's production areas. Patients had an insidious onset of cough, wheeze, and exertional dyspnea; airflow obstruction (mean FEV1 = 44% predicted) and reduced diffusing capacity (mean = 53% predicted); and radiologic centrilobular emphysema. Lung tissue demonstrated a unique pattern of bronchiolitis and alveolar ductitis with B-cell follicles lacking germinal centers, and significant emphysema for never-smokers. All had chronic dyspnea, three had a progressive functional decline, and one underwent lung transplantation. Patients reported no unusual nonoccupational exposures. No cases were identified among nonproduction workers or in the community. Endotoxin concentrations were elevated in two air samples; otherwise, exposures were below occupational limits. Air flowed from areas where machining occurred to other production areas. Metalworking fluid primarily grew Pseudomonas pseudoalcaligenes and lacked mycobacterial DNA, but 16S analysis revealed more complex bacterial communities. CONCLUSION: This cluster indicates a previously unrecognized occupational lung disease of yet uncertain etiology that should be considered in manufacturing workers (particularly never-smokers) with airflow obstruction and centrilobular emphysema. Investigation of additional cases in other settings could clarify the cause and guide prevention. |
Hurricane-associated mold exposures among patients at risk for invasive mold infections after Hurricane Harvey - Houston, Texas, 2017
Chow NA , Toda M , Pennington AF , Anassi E , Atmar RL , Cox-Ganser JM , Da Silva J , Garcia B , Kontoyiannis DP , Ostrosky-Zeichner L , Leining LM , McCarty J , Al Mohajer M , Murthy BP , Park JH , Schulte J , Shuford JA , Skrobarcek KA , Solomon S , Strysko J , Chiller TM , Jackson BR , Chew GL , Beer KD . MMWR Morb Mortal Wkly Rep 2019 68 (21) 469-473 In August 2017, Hurricane Harvey caused unprecedented flooding and devastation to the Houston metropolitan area (1). Mold exposure was a serious concern because investigations after Hurricanes Katrina and Rita (2005) had documented extensive mold growth in flood-damaged homes (2,3). Because mold exposure can cause serious illnesses known as invasive mold infections (4,5), and immunosuppressed persons are at high risk for these infections (6,7), several federal agencies recommend that immunosuppressed persons avoid mold-contaminated sites (8,9). To assess the extent of exposure to mold and flood-damaged areas among persons at high risk for invasive mold infections after Hurricane Harvey, CDC and Texas health officials conducted a survey among 103 immunosuppressed residents in Houston. Approximately half of the participants (50) engaged in cleanup of mold and water-damaged areas; these activities included heavy cleanup (23), such as removing furniture or removing drywall, or light cleanup (27), such as wiping down walls or retrieving personal items. Among immunosuppressed persons who performed heavy cleanup, 43% reported wearing a respirator, as did 8% who performed light cleanup. One participant reported wearing all personal protective equipment (PPE) recommended for otherwise healthy persons (i.e., respirator, boots, goggles, and gloves). Immunosuppressed residents who are at high risk for invasive mold infections were exposed to mold and flood-damaged areas after Hurricane Harvey; recommendations from health care providers to avoid exposure to mold and flood-damaged areas could mitigate the risk to immunosuppressed persons. |
Seroepidemiology of Hepatitis Viruses and Hepatitis B Genotypes of Female Marriage Immigrants in Korea.
Kwon JC , Chang HY , Kwon OY , Park JH , Oh IS , Kim HJ , Lee JH , Roh HJ , Lee HW . Yonsei Med J 2018 59 (9) 1072-1078 PURPOSE: The Korean society has moved rapidly toward becoming a multicultural society. This study aimed to estimate the seroprevalence of hepatitis viruses and investigate hepatitis B virus (HBV) genotypic diversity in female marriage immigrants. MATERIALS AND METHODS: Screening program was conducted at support centers for multicultural families in 21 administrative districts in Korea between July 2011 and January 2017. A total of 963 female marriage immigrants were included in this study. Blood samples were tested for hepatitis viral markers and HBV genotype. RESULTS: Subjects' median age was 33 years (20-40 years), and they originated from nine countries including Vietnam (n=422, 43.8%), China (n=311, 32.3%), the Philippines (n=85, 8.8%), Cambodia (n=58, 6.0%), and Japan (n=39, 4.0%). About 30% (n=288) of subjects required hepatitis A vaccination. HBsAg positive rate was 5.4% (n=52). Positive HBsAg results were the highest in subjects from Southeast Asia (6.6%, n=38). Anti-HBs positive rate was 60.4% (n=582). About 34% (n=329) of subjects who were negative for anti-HBs and HBsAg required HBV vaccinations. Genotypes B and C were found in 54.6% (n=12) and 45.4% (n=10) of the 22 subjects with HBV, in whom genotypes were tested. Eight (0.8%) subjects were positive for anti-HCV. Positive anti-HCV results were the highest in subjects from Central Asia (7.9%, n=3). CONCLUSION: Testing for hepatitis viral marker (hepatitis A virus IgG and HBsAg/anti-HBs) is needed for female marriage immigrants. Especially, HBV genotype B is different from genotype C of Koreans. Therefore, interest and attention to vaccination programs for female marriage immigrants are necessary for both clinicians and public health institutes. |
Characterization of fungi in office dust: comparing results of microbial secondary metabolites, fungal ITS region sequencing, viable culture, and other microbial indices
Park JH , Sulyok M , Lemons AR , Green BJ , Cox-Ganser JM . Indoor Air 2018 Recent developments in molecular and chemical methods have enabled the analysis of fungal DNA and secondary metabolites, often produced during fungal growth, in environmental samples. We compared three fungal analytical methods by analyzing floor dust samples collected from an office building for fungi using viable culture, internal transcribed spacer (ITS) sequencing, and secondary metabolites using liquid chromatography-tandem mass spectrometry. Of the 32 metabolites identified, 29 had a potential link to fungi with levels ranging from 0.04 (minimum for alternariol monomethylether) to 5,700 ng/g (maximum for neoechinulin A). The number of fungal metabolites quantified per sample ranged from eight to sixteen (average=13/sample). We identified 216 fungal operational taxonomic units (OTUs) with the number per sample ranging from six to twenty-nine (average=18/sample). We identified 37 fungal species using culture and the number per sample ranged from two to thirteen (average=eight/sample). Agreement in identification between ITS sequencing and culturing was weak (kappa=-0.12-0.27). The number of cultured fungal species poorly correlated with OTUs, which did not correlate with the number of metabolites. These suggest that using multiple measurement methods may provide an improved understanding of fungal exposures in indoor environments and that secondary metabolites may be considered as an additional source of exposure. This article is protected by copyright. All rights reserved. |
Changes in respiratory and non-respiratory symptoms in occupants of a large office building over a period of moisture damage remediation attempts
Park JH , Cho SJ , White SK , Cox-Ganser JM . PLoS One 2018 13 (1) e0191165 There is limited information on the natural history of building occupants' health in relation to attempts to remediate moisture damage. We examined changes in respiratory and non-respiratory symptoms in 1,175 office building occupants over seven years with multiple remediation attempts. During each of four surveys, we categorized participants using a severity score: 0 = asymptomatic; 1 = mild, symptomatic in the last 12 months, but not frequently in the last 4 weeks; 2 = severe, symptomatic at least once weekly in the last 4 weeks. Building-related symptoms were defined as improving away from the building. We used random intercept models adjusted for demographics, smoking, building tenure, and microbial exposures to estimate temporal changes in the odds of building-related symptoms or severity scores independent of the effect of microbial exposures. Trend analyses of combined mild/severe symptoms showed no changes in the odds of respiratory symptoms but significant improvement in non-respiratory symptoms over time. Separate analyses showed increases in the odds of severe respiratory symptoms (odds ratio/year = 1.151.16, p-values<0.05) and severity scores (0.02/year, p-values<0.05) for wheezing and shortness of breath on exertion, due to worsening of participants in the mild symptom group. For non-respiratory symptoms, we found no changes in the odds of severe symptoms but improvement in severity scores (-0.04-0.01/year, p-values<0.05) and the odds for mild fever and chills, excessive fatigue, headache, and throat symptoms (0.65-0.79/year, p-values<0.05). Our study suggests that after the onset of respiratory and severe non-respiratory symptoms associated with dampness/mold, remediation efforts might not be effective in improving occupants' health. |
Quantification of mold contamination in multi-level buildings using the Environmental Relative Moldiness Index
Vesper S , Cox-Ganser JM , Wymer L , Park JH . J Occup Environ Hyg 2017 15 (1) 0 The goal of this study was to evaluate the possible use of the Environmental Relative Moldiness Index (ERMI) to quantify mold contamination in multi-level, office buildings. Settled-dust samples were collected in multi-level, office buildings and the ERMI value for each sample determined. In the first study, a comparison was made between two identical four-story buildings. There were health complaints in one building but none in the other building. In the second study, mold contamination was evaluated on levels 6 through 19 of an office building with a history of water problems and health complaints. In the first study, the average ERMI value in the building with health complaints was 5.33 which was significantly greater than the average ERMI value, 0.55, in the non-complaint building. In the second study, the average ERMI values ranged from a low of -0.58 on level 8 to a high of 5.66 on level 17, one of the top five ranked levels for medical symptoms or medication use. The mold populations of ten (six Group 1 and four Group 2) of the 36-ERMI molds were in significantly greater concentrations in the higher compared to lower ERMI environments. The ERMI metric may be useful in the quantification of water-damage and mold growth in multi-level buildings. |
Microbial rRNA sequencing analysis of evaporative cooler indoor environments located in the Great Basin Desert region of the United States.
Lemons AR , Hogan MB , Gault RA , Holland K , Sobek E , Olsen-Wilson KA , Park Y , Park JH , Gu JK , Kashon ML , Green BJ . Environ Sci Process Impacts 2017 19 (2) 101-110 Recent studies conducted in the Great Basin Desert region of the United States have shown that skin test reactivity to fungal and dust mite allergens are increased in children with asthma or allergy living in homes with evaporative coolers (EC). The objective of this study was to determine if the increased humidity previously reported in EC homes leads to varying microbial populations compared to homes with air conditioners (AC). Children with physician-diagnosed allergic rhinitis living in EC or AC environments were recruited into the study. Air samples were collected from the child's bedroom for genomic DNA extraction and metagenomic analysis of bacteria and fungi using the Illumina MiSeq sequencing platform. The analysis of bacterial populations revealed no major differences between EC and AC sampling environments. The fungal populations observed in EC homes differed from AC homes. The most prevalent species discovered in AC environments belonged to the genera Cryptococcus (20%) and Aspergillus (20%). In contrast, the most common fungi identified in EC homes belonged to the order Pleosporales and included Alternaria alternata (32%) and Phoma spp. (22%). The variations in fungal populations provide preliminary evidence of the microbial burden children may be exposed to within EC environments in this region. |
Assessment of fungal diversity in a water-damaged office building.
Green BJ , Lemons AR , Park Y , Cox-Ganser JM , Park JH . J Occup Environ Hyg 2016 14 (4) 285-293 Recent studies have described fungal communities in indoor environments using gene sequencing-based approaches. In this study, dust-borne fungal communities were elucidated from a water-damaged office building located in the northeastern region of the United States using internal transcribed spacer (ITS) rRNA gene sequencing. Genomic DNA was extracted from 5 mg of floor dust derived from 22 samples collected from either the lower floors (n = 8) or a top floor (n = 14) of the office building. ITS gene sequencing resolved a total of 933 ITS sequences and was clustered into 216 fungal operational taxonomic units (OTUs). Analysis of fungal OTUs at the 97% similarity threshold showed a difference between the lower and top floors that was marginally significant (p = 0.049). Species richness and diversity indices were reduced in the lower floor samples compared to the top floor samples and there was a high degree of compositional dissimilarity within and between the two different areas within the building. Fungal OTUs were placed in the phyla Ascomycota (55%), Basidiomycota (41%), Zygomycota (3%), Glomeromycota (0.4%), Chytridiomycota (0.3%) and unassigned fungi (0.5%). The Ascomycota classes with the highest relative abundances included the Dothideomycetes (30%) and Eurotiomycetes (16%). The Basidiomycota consisted of the classes Ustilaginomycetes (14%), Tremellomycetes (11%), and Agaricomycetes (8%). Sequence reads derived from the plant pathogen Ustilago syntherismae were the most abundant in the analysis as were obligate Basidiomycota yeast species that accounted for 12% and 11% of fungal ITS sequences, respectively. ITS gene sequencing provides additional insight into the diversity of fungal OTUs. These data further highlight the contribution of fungi placed in the phylum Basidiomycota, obligate yeasts, as well as xerophilic species that are typically not resolved using traditional culture methods. |
Measurement of macrocyclic trichothecene in floor dust of water-damaged buildings using gas chromatography/tandem mass spectrometry- dust matrix effects
Saito R , Park JH , LeBouf R , Green BJ , Park Y . J Occup Environ Hyg 2016 13 (6) 0 Gas chromatography-tandem mass spectrometry (GC-MS/MS) was used to detect fungal secondary metabolites. Detection of verrucarol, the hydrolysis product of Stachybotrys chartarum macrocyclic trichothecene (MCT), was confounded by matrix effects associated with heterogeneous indoor environmental samples. In this study, we examined the role of dust matrix effects associated with GC-MS/MS to better quantify verrucarol in dust as a measure of total MCT. The efficiency of the internal standard (ISTD, 1,12-dodecanediol), and application of a matrix-matched standard correction method in measuring MCT in floor dust of water-damaged buildings was additionally examined. Compared to verrucarol, ISTD had substantially higher matrix effects in the dust extracts. The results of the ISTD evaluation showed that without ISTD adjustment, there was a 280% ion enhancement in the dust extracts compared to neat solvent. The recovery of verrucarol was 94% when the matrix-matched standard curve without the ISTD was used. Using traditional calibration curves with ISTD adjustment, none of the 21 dust samples collected from water damaged buildings were detectable. In contrast, when the matrix-matched calibration curves without ISTD adjustment were used, 38% of samples were detectable. The study results suggest that floor dust of water-damaged buildings may contain MCT. However, the measured levels of MCT in dust using the GC-MS/MS method could be significantly under- or overestimated, depending on the matrix effects, the inappropriate ISTD, or combination of the two. Our study further shows that the routine application of matrix-matched calibration may prove useful in obtaining accurate measurements of MCT in dust derived from damp indoor environments, while no isotopically-labeled verrucarol is available. |
- Page last reviewed:Feb 1, 2024
- Page last updated:Sep 30, 2024
- Content source:
- Powered by CDC PHGKB Infrastructure