Last data update: Jan 13, 2025. (Total: 48570 publications since 2009)
Records 1-24 (of 24 Records) |
Query Trace: Nwankwo T[original query] |
---|
Exogenous Rubella Virus Capsid Proteins Enhance Virus Genome Replication.
Chen MH , Burns CC , Abernathy E , Ogee-Nwankwo AA , Icenogle JP . Pathogens 2022 11 (6) Enhanced replication of rubella virus (RuV) and replicons by de novo synthesized viral structural proteins has been previously described. Such enhancement can occur by viral capsid proteins (CP) alone in trans. It is not clear whether the CP in the virus particles, i.e., the exogenous CP, modulate viral genome replication. In this study, we found that exogenous RuV CP also enhanced viral genome replication, either when used to package replicons or when mixed with RNA during transfection. We demonstrated that CP does not affect the translation efficiency from genomic (gRNA) or subgenomic RNA (sgRNA), the intracellular distribution of the non-structural proteins (NSP), or sgRNA synthesis. Significantly active RNA replication was observed in transfections supplemented with recombinant CP (rCP), which was supported by accumulated genomic negative-strand RNA. rCP was found to restore replication of a few mutants in NSP but failed to fully restore replicons known to have defects in the positive-strand RNA synthesis. By monitoring the amount of RuV RNA following transfection, we found that all RuV replicon RNAs were well-retained in the presence of rCP within 24 h of post-transfection, compared to non-RuV RNA. These results suggest that the exogenous RuV CP increases efficiency of early viral genome replication by modulating the stage(s) prior to and/or at the initiation of negative-strand RNA synthesis, possibly through a general mechanism such as protecting viral RNA. |
Notes from the field: Response to measles among persons evacuated from Afghanistan - Joint Base McGuire-Dix-Lakehurst, New Jersey, August-October 2021
Pritchard N , Worrell MC , Shahum A , Nwankwo A , Smith D , Koch JJ , Ballard T . MMWR Morb Mortal Wkly Rep 2022 71 (17) 609-610 On August 29, 2021, the U.S. government initiated Operation Allies Welcome (OAW) to resettle eligible persons from Afghanistan. Evacuees were housed at military bases in the United States while completing immigration resettlement processing. On September 4, 2021, the Fort McCoy, Wisconsin, OAW site reported the first confirmed case of measles in an Afghan evacuee; during the subsequent 10 days, five additional cases were identified across multiple sites (1). On September 6, OAW response leadership learned that 16 evacuees at Joint Base McGuire-Dix-Lakehurst (JBMDL) had been exposed to a patient with confirmed measles during a September 3 United States-bound flight. Because of low routine measles vaccination coverage rates in Afghanistan (2), risk for measles transmission was high among evacuees at JBMDL, a population that would expand to >10,000 persons living in large tents and multifamily rooms, if any exposed evacuees developed measles. During September 7–9, the JBMDL OAW public health team, with support from local and state health departments and guidance from CDC, provided measles, mumps, and rubella (MMR) vaccine or immunoglobulin to exposed persons. Because of delayed reporting of the exposures and challenges locating evacuees, whose lodgings assignments were not always well documented or might have changed, postexposure prophylaxis was not administered within the recommended time frame.* Exposed persons were asked to quarantine and complied; however, because of space constraints, they were not moved into quarantine until 1 week after the exposure. None of the evacuees exposed to the patient on September 3 experienced measles signs or symptoms† during quarantine. This activity was reviewed by CDC and was conducted consistent with applicable federal law and CDC policy.§ |
Differences in hypertension and stage II hypertension by demographic and risk factors, obtained by two different protocols in US adults: National Health and Nutrition Examination Survey, 2017-2018
Ostchega Y , Hughes JP , Kit B , Chen TC , Nwankwo T , Commodore-Mensah Y , Graber JE , Nguyen DT . Am J Hypertens 2022 35 (7) 619-626 OBJECTIVE: To compare prevalence of hypertension and stage II hypertension assessed by two blood pressure observation protocols. METHODS: Participants aged 18 years and older (n = 4,689) in the National Health and Nutrition Examination Survey (NHANES 2017-2018) had their blood pressure (BP) measured following two protocols: the legacy auscultation protocol [AP] and oscillometric protocol [OP]. The order of protocols was randomly assigned. Prevalence estimates for hypertension (BP 130/80 mm Hg or use of medication for hypertension) and stage II hypertension (BP 140/90 mm Hg) were determined overall, by demographics, and by risk factors for each protocol. Ratios (OP% AP%) and Kappa statistics were calculated. RESULTS: Age-adjusted hypertension prevalence was 44.5% (95% CI: 41.1%-48.0%) using OP and 45.1% (95%CI: 41.5%-48.7%) using AP, prevalence ratio=0.99, (95% CI=0.94-1.04)). Age-adjusted Stage II hypertension prevalence was 15.8% (95% CI: 13.6%-18.2%) using AP and 17.1% (95% CI: 14.7%-19.7%) using OP, prevalence ratio=0.92, (95% CI=0.81-1.04)). For both hypertension and Stage II hypertension, the prevalence ratios by demographics and by risk factors all included unity in their 95% CI, except for Stage II hypertension in adults 60+ years (ratio: 0.88 (95% CI: 0.78-0.98)). Kappa for agreement between protocols for hypertension and stage II hypertension were 0.75 (95% CI=0.71-0.79) and 0.67 (95% CI=0.61-0.72), respectively. CONCLUSIONS: In adults and for nearly all subcategories there were no significant differences in prevalence of hypertension and stage II hypertension between protocols, indicating that protocol change may not affect the national prevalence estimates of hypertension and stage II hypertension. |
Differences in hypertension prevalence and hypertension control by urbanization among adults in the United States, 2013-2018
Ostchega Y , Hughes JP , Zhang G , Nwankwo T , Graber J , Nguyen DT . Am J Hypertens 2021 35 (1) 31-41 OBJECTIVE: To examine the associations between urbanization and hypertension, stage II hypertension, and hypertension control. METHODS: Data on 16,360 U.S. adults aged 18 years or older from the 2013-2018 National Health and Nutrition Examination Survey (NHANES) were used to estimate the prevalence of hypertension (blood pressure (BP) ≥130/80 mm Hg or use of medication for hypertension), stage II hypertension (BP ≥140/90 mm Hg), and hypertension control (BP < 130/80 mm Hg among hypertensives) by urbanization, classified by levels of metropolitan statistical areas as large MSAs (population ≥ 1,000,000), medium to small MSAs (population 50,000-999,999), and non-MSAs (population <50,000)). RESULTS: All prevalence ratios (PRs) were compared with large MSAs and adjusted for demographics and risk factors. The PRs of hypertension were 1.07 (95% CI= 0.99-1.14) for adults residing in medium to small MSAs and 1.06 (95% CI=0.99- 1.13) for adults residing in non-MSAs, For stage II hypertension, the PRs were higher for adults residing in medium to small MSAs 1.21 (95% CI =1.06-1.36) but not for adults residing in non-MSAs 1.06 (95% CI= 0.88-1.29). For hypertension control, the PRs were 0.96 (95% CI=0.91-1.01) for adults residing in medium to small MSAs and 1.00 (95% CI=0.93-1.06) for adults residing in non-MSAs. CONCLUSION: Among U.S. adults, urbanization was associated with stage II hypertension. |
Comparison of three devices for 24-hour ambulatory blood pressure monitoring in a nonclinical environment through a randomized trial
Nwankwo T , Coleman King SM , Ostchega Y , Zhang G , Loustalot F , Gillespie C , Chang TE , Begley EB , George MG , Shimbo D , Schwartz JE , Muntner P , Kronish IM , Hong Y , Merritt R . Am J Hypertens 2020 33 (11) 1021-1029 BACKGROUND: The U.S. Preventive Services Task Force recommends the use of 24-hour ambulatory blood pressure monitoring (ABPM) as part of screening and diagnosis of hypertension. The optimal ABPM device for population-based surveys is unknown. OBJECTIVE: Among three ABPM devices, we compared the proportion of valid BP readings, mean awake and asleep BP readings, differences between awake ABPM readings and initial standardized BP readings, and sleep experience. RESULTS: The proportions of valid blood pressure readings were not different among the three devices ( p > 0.45). Mean awake and asleep systolic BP were significantly higher for STO device (WA vs. STO vs. SL: 126.65 mmHg, 138.09 mmHg, 127.44 mmHg; 114.34 mmHg, 120.34 mmHg, 113.13 mmHg; p <0.0001 for both). The difference between the initial average standardized mercury systolic BP readings and the ABPM mean awake systolic BP was larger for STO device (WA vs. STO. vs. SL: -5.26 mmHg, -16.24 mmHg, -5.36 mmHg; p <0.0001); diastolic BP mean differences were ~ -6 mmHg for all three devices ( p =0.6). Approximately 55% of participants reported that the devices interfered with sleep; however, there were no sleep differences across the devices (p >0.4 for all). CONCLUSION: Most of the participants met the threshold of 70% valid readings over 24 hours. Sleep disturbance was common but did not interfere with completion of measurement in most of the participants. |
Mean mid-arm circumference and blood pressure cuff sizes for US children, adolescents and adults: National Health and Nutrition Examination Survey, 2011-2016
Ostchega Y , Hughes JP , Nwankwo T , Zhang G . Blood Press Monit 2018 23 (6) 305-311 BACKGROUND: Measuring blood pressure (BP) requires an appropriate BP cuff size given measured mid-arm circumference (mid-AC). OBJECTIVE: To provide mid-AC means and percentiles for US population aged more than 3 years and examine the frequency distribution of mid-AC cuffed by Baum and Welch Allyn cuff systems. PATIENTS AND METHODS: The 2011-2016 National Health and Nutrition Examination Survey, a cross-sectional survey, was used to estimate mean mid-AC (n=24 723). RESULTS: Mean mid-AC did not differ from 2011 to 2016 (31.0 vs. 31.3 cm, P>0.05). During 2011-2016, mean mid-AC was greater for males than females (32.0 vs. 30.4 cm, P<0.001) and was largest among adults 40-49 years (34.0 cm). Non-Hispanic Black persons had the largest mean mid-AC (32.0 cm) and non-Hispanic Asian persons the smallest (28.4 cm). Increased BMI was associated with increased mean mid-AC for those 3-19 years (normal, 22.0 cm and obese, 31.5 cm, P<0.001) and more than 20 years (normal, 28.2 cm and obese, 37.8 cm, P<0.001). Among those aged 8-17 years, high BP status was associated with a larger mean mid-AC (normotensive 26.1 cm vs. high BP 28.2 cm, P=0.001). Among adults aged 18 years and older, hypertension status was associated with a larger mean mid-AC (normotensive 32.4 cm vs. hypertensive 34.2 cm, P<0.001). Among those aged 12-19 years, 13.0% required a Baum large cuff (35-46.9 cm mid-AC) and 21.7% required a Welch Allyn large cuff (32-39.9 cm mid-AC). Among those aged more than 20 years, 33.2% required a Baum large cuff, 48.2% required a Welch Allyn large cuff, 1.3% required a Baum extra-large cuff (44-66 cm mid-AC), and 9.5% required a Welch Allyn extra-large cuff (40-55 cm mid-AC). CONCLUSION: Currently, BP is obtained in clinic, pharmacy, home, and ambulatory setting using single or multiple cuffs. National Health and Nutrition Examination Survey mid-AC data should be considered for accurate cuffing avoiding cuff hypertension or hypotension. |
Rubella virus neutralizing antibody response after a third dose of measles-mumps-rubella vaccine in young adults
McLean HQ , Fiebelkorn AP , Ogee-Nwankwo A , Hao L , Coleman LA , Adebayo A , Icenogle JP . Vaccine 2018 36 (38) 5732-5737 BACKGROUND: Third doses of measles-mumps-rubella (MMR) vaccine have been administered during mumps outbreaks and in various non-outbreak settings. The immunogenicity of the rubella component has not been evaluated following receipt of a third dose of MMR vaccine. METHODS: Young adults aged 18-31years with documented two doses of MMR vaccine received a third dose of MMR vaccine between July 2009 and October 2010. Rubella neutralizing antibody titers were assessed before, 1month, and 1year after receipt of a third dose of MMR vaccine. RESULTS: Among 679 participants, 1.8% had rubella antibody titers less than 10 U/ml, immediately before vaccination, approximately 15years after receipt of a second dose of MMR vaccine. One month after receipt of a third dose of MMR vaccine, average titers were 4.5 times higher and >50% of participants had a 4-fold boost. Response was highest among those with titers less than 10 U/ml prior to vaccination (geometric mean titer ratio=18.8; 92% seroconversion) and decreased with increasing pre-vaccination titers. Average titers declined 1year postvaccination but remained significantly higher than pre-vaccination levels. The proportion classified as low-positive antibody levels increased from 3% 1month postvaccination to 24% 1year postvaccination. CONCLUSIONS: Vaccination with a third dose of MMR vaccine resulted in a robust boosting of rubella neutralizing antibody response that remained elevated 1year later. Young adults with low rubella titers are more likely to benefit from a third dose of MMR vaccine. |
Factors associated with hypertension control in U.S. adults using 2017 ACC/AHA Guidelines: National Health and Nutrition Examination Survey 1999-2016
Ostchega Y , Zhang G , Hughes J , Nwankwo T . Am J Hypertens 2018 31 (8) 886-894 Background: Factors and trends associated with hypertension control (BP <130/<80 mm Hg) and mean blood pressure (BP) among hypertensive adults (BP >/=130/80 mm Hg or medicated for hypertension). Method: Data on 22,911 hypertensive US adults from the 1999-2016 National Health and Nutrition Examination Survey. Results: For men, hypertension control prevalence increased from 8.6% in 1999-2000 to 16.2% in 2003-2004 (P<0.001), and continued the increasing trend afterwards to 23.2% in 2011-2012 (P<0.001) and then plateaued. For women, hypertension control prevalence increased from 1999-2000 to 2009-2010 (10.8% to 26.3%, P<0.001) and then plateaued. For men with hypertension, systolic BP decreased from 1999-2000 to 2011-2012 (135.7 mmHg to 132.8 mmHg, P<0.001) and then increased to 135.3 mmHg in 2015-2016 (P<0.001). For women with hypertension, systolic BP decreased from 1999-2000 to 2009-2010 (139.7 mmHg to 131.9 mmHg; p<.001) and then increased to 134.4 mmHg in 2015-2016 (P = 0.003). Diastolic BP decreased from 1999-2000 to 2015-2016 (men 79.1 mmHg to 75.5 mmHg and women 76.4 mmHg to 73.7 mmHg, P<.001 for both). In 2011 to 2016, hypertension control was 22.0% for men and 25.2% for women. The adjusted prevalence ratio (PR) of hypertension control were lower for non-Hispanic black men and women (PR=0.72, 95%C I=0.61-0.86; PR=0.83, 95%CI=0.70-0.99, respectively; non-Hispanic white (NHW) as reference), Hispanic and non-Hispanic Asian men (PR=0.70, 95%CI=0.54-0.92; PR=0.59, 95%CI=0.39-0.86; respectively; NHW as reference). Conclusion: Hypertension control significantly increased from 1999-2000 to 2011-2012(men) and 2009-2010 (women) and then plateaued. About a quarter of US adults with hypertension were controlled in 2011-2016. |
Assessment of National Public Health and Reference Laboratory, Accra, Ghana, within framework of global health security
Ogee-Nwankwo A , Opare D , Boateng G , Nyaku M , Haynes LM , Balajee SA , Conklin L , Icenogle JP , Rota PA , Waku-Kouomou D . Emerg Infect Dis 2017 23 (13) S121-5 The Second Year of Life project of the Global Health Security Agenda aims to improve immunization systems and strengthen measles and rubella surveillance, including building laboratory capacity. A new laboratory assessment tool was developed by the Centers for Disease Control and Prevention to assess the national laboratory in Ghana to improve molecular surveillance for measles and rubella. Results for the tool showed that the laboratory is well organized, has a good capacity for handling specimens, has a good biosafety system, and is proficient for diagnosis of measles and rubella by serologic analysis. However, there was little knowledge about molecular biology and virology activities (i.e., virus isolation on tissue culture was not available). Recommendations included training of technical personnel for molecular techniques and advocacy for funding for laboratory equipment, reagents, and supplies. |
Status of HIV epidemic control among adolescent girls and young women aged 15-24 years - seven African countries, 2015-2017
Brown K , Williams DB , Kinchen S , Saito S , Radin E , Patel H , Low A , Delgado S , Mugurungi O , Musuka G , Tippett Barr BA , Nwankwo-Igomu EA , Ruangtragool L , Hakim AJ , Kalua T , Nyirenda R , Chipungu G , Auld A , Kim E , Payne D , Wadonda-Kabondo N , West C , Brennan E , Deutsch B , Worku A , Jonnalagadda S , Mulenga LB , Dzekedzeke K , Barradas DT , Cai H , Gupta S , Kamocha S , Riggs MA , Sachathep K , Kirungi W , Musinguzi J , Opio A , Biraro S , Bancroft E , Galbraith J , Kiyingi H , Farahani M , Hladik W , Nyangoma E , Ginindza C , Masangane Z , Mhlanga F , Mnisi Z , Munyaradzi P , Zwane A , Burke S , Kayigamba FB , Nuwagaba-Biribonwoha H , Sahabo R , Ao TT , Draghi C , Ryan C , Philip NM , Mosha F , Mulokozi A , Ntigiti P , Ramadhani AA , Somi GR , Makafu C , Mugisha V , Zelothe J , Lavilla K , Lowrance DW , Mdodo R , Gummerson E , Stupp P , Thin K , Frederix K , Davia S , Schwitters AM , McCracken SD , Duong YT , Hoos D , Parekh B , Justman JE , Voetsch AC . MMWR Morb Mortal Wkly Rep 2018 67 (1) 29-32 In 2016, an estimated 1.5 million females aged 15-24 years were living with human immunodeficiency virus (HIV) infection in Eastern and Southern Africa, where the prevalence of HIV infection among adolescent girls and young women (3.4%) is more than double that for males in the same age range (1.6%) (1). Progress was assessed toward the Joint United Nations Programme on HIV/AIDS (UNAIDS) 2020 targets for adolescent girls and young women in sub-Saharan Africa (90% of those with HIV infection aware of their status, 90% of HIV-infected persons aware of their status on antiretroviral treatment [ART], and 90% of those on treatment virally suppressed [HIV viral load <1,000 HIV RNA copies/mL]) (2) using data from recent Population-based HIV Impact Assessment (PHIA) surveys in seven countries. The national prevalence of HIV infection in adolescent girls and young women aged 15-24 years, the percentage who were aware of their status, and among those persons who were aware, the percentage who had achieved viral suppression were calculated. The target for viral suppression among all persons with HIV infection is 73% (the product of 90% x 90% x 90%). Among all seven countries, the prevalence of HIV infection among adolescent girls and young women was 3.6%; among those in this group, 46.3% reported being aware of their HIV-positive status, and 45.0% were virally suppressed. Sustained efforts by national HIV and public health programs to diagnose HIV infection in adolescent girls and young women as early as possible to ensure rapid initiation of ART should help achieve epidemic control among adolescent girls and young women. |
Factors associated with home blood pressure monitoring among US adults: National Health and Nutrition Examination Survey, 2011-2014
Ostchega Y , Zhang G , Kit BK , Nwankwo T . Am J Hypertens 2017 30 (11) 1126-1132 BACKGROUND: Home blood pressure monitoring (HBPM) has a substantial role in hypertension management and control. METHODS: Cross-sectional data for noninstitutionalized US adults 18 years and older (10,958) from the National Health and Nutrition Examination Survey (NHANES), years 2011-2014, were used to examine factors related to HBPM. RESULTS: In 2011-2014, estimated 9.5% of US adults engaged in weekly HBPM, 7.2% engaged in monthly HBPM, 8.0% engaged in HBPM less than once a month, and 75.3% didn't engage any HBPM. The frequency of HBPM increased with age, body mass index, and the number of health care visits (all, P < 0.05). Also, race/ethnicity (Non-Hispanic Blacks and non-Hispanic Asians), health insurance, diagnosed with diabetes, told by a health care provider to engage in HBPM, and diagnosed as hypertensive, were all associated with more frequent HBPM (P < 0.05). Adjusting for covariates, hypertensives who were aware of, treated for, and controlled engaged in more frequent HBPM compared to their respective references: unaware (odds ratio [OR] = 2.00, 95% confidence interval [CI] = 1.53-2.63), untreated (OR = 1.99, 95% CI = 1.52-2.60), and uncontrolled (OR = 1.42, 95% CI = 1.13-1.82). Hypertensive adults (aware/unaware, treated/untreated, or controlled/uncontrolled), who received providers' recommendations to perform HBPM, were more likely to do so compared to those who did not receive recommendations (OR = 8.04, 95% CI = 6.56-9.86; OR = 7.98, 95% CI = 6.54-9.72; OR = 8.75, 95% CI = 7.18-10.67, respectively). CONCLUSIONS: Seventeen percent of US adults engaged in monthly or more frequent HBPM and health care providers' recommendations to engage in HBPM have a significant impact on the frequency of HBPM. |
Comparison of blood pressure measurements obtained in the home setting: Analysis of the Health Measures at Home Study
Nwankwo T , Gindi R , Chen TC , Galinsky A , Miller I , Terry A . Blood Press Monit 2016 21 (6) 327-334 BACKGROUND: Automated blood pressure (BP) devices have been used in the home for self-management purposes and are increasingly being used in population-based research. Although these devices are convenient and affordable and may be used by inexperienced lay personnel, the potential impact of an examiner's skill level on the results needs to be evaluated quantitatively. The aim of this study was to compare BP measurements obtained in a home setting by personnel with healthcare experience with those obtained by personnel without healthcare experience. In addition, the percent agreement in high blood pressure (HBP) classification between the home BP measurement by the field interviewer (FI) and measurements obtained in a standardized environment was examined. METHODS: The Health Measures at Home Study was a pilot study carried out among 128 adult participants recruited from the National Health and Nutrition Examination Survey. The Health Measures at Home Study provided the opportunity to compare the BP values obtained with an automated device in a home setting by both experienced health technicians (HTs) with those obtained by FIs who had no healthcare experience. Differences between measurements obtained by the HT and measurements obtained by the FI were assessed using paired t-tests, Pearson's correlations, and Bland-Altman plots. Percent agreement and kappa-statistics were used to assess agreement in HBP classification between examiners in the home. Measurements obtained by the FI were also compared with those obtained in the National Health and Nutrition Examination Survey mobile exam center (MEC) by a physician using percent agreement and kappa-statistics. RESULTS: There was a high correlation in both systolic blood pressure (SBP; r=0.903) and diastolic blood pressure (DBP; r=0.894) between measurements obtained by HTs and those obtained by FIs. The mean SBP and DBP obtained by the FIs (SBP, 119.0+/-14.4 mmHg; DBP, 71.9+/-9.8 mmHg) were significantly higher than the HT measurements (SBP, 117.0+/-12.7 mmHg; DBP, 69.9.9+/-9.2 mmHg). In the home, the FI classified 11.7% as having HBP, whereas the HT classified 7.0%. The percent of individuals classified as having HBP by the physician in the MEC was 10.2% of the participants. CONCLUSION: Operationally, FIs could take BP measurements in the home; however, there were some differences between measurements obtained by the FI and HT. The absolute difference between measurements obtained by the FI and those obtained by the HT in the home showed that measurements obtained by the FI tended to be higher than the HT, but the magnitude of these differences was less than 5 mmHg. The HT classified 7.0% of HBP whereas the FI classified 11.7% of HBP. Similarly, the FI and the MEC physician classified a different percent of individuals with HBP. Further investigation is warranted to determine the cause of these small but significant absolute differences between measurements obtained by the FI and HT. |
Blood pressure cuff comparability study
Ostchega Y , Nwankwo T , Zhang G , Chiappa M . Blood Press Monit 2016 21 (6) 345-351 BACKGROUND: Manufacturer-supplied blood pressure (BP) cuffs are part of the automatic oscillometric BP devices algorithm. MATERIALS AND METHODS: This study assessed the differences in BP values using the Omron HEM 907-XL (Omron) device with two types of cuffs: the Baum cuff (BC) and the supplied Omron cuff (OC). A sample of 102 adults participated in the study, 34 per cuff size (adult, large, and extra-large). After a 5-min resting period, three pairs of BP determinations (systolic and diastolic) were taken simultaneously on both arms. One arm was cuffed with a BC and the other arm was cuffed with an OC. The cuffs were switched to opposite arms after 5 min of rest. The order was decided randomly as to which cuff was applied to which arm first. RESULTS: The BP readings were highly correlated between the cuffs (systolic BP, r=0.98; diastolic BP, r=0.98). The overall mean differences (BC-OC) were 2.66 mmHg (SD=3.9 mmHg) for systolic BP (P<0.05) and 0.33 mmHg (SD=2.03 mmHg) for diastolic BP (P>0.05). Increased cuff size corresponded to increased differences in systolic BP values (adult: 1.51 mmHg; large: 2.56 mmHg; and extra-large: 3.9 mmHg; P<0.05). For diastolic BP values, a statistically significant difference was observed only for adult cuff size (difference=1.31 mmHg, SD=1.34 mmHg, P<0.05). CONCLUSION: Using a BC with the Omron could result in higher systolic BP readings and higher diastolic BP readings with the adult cuff size. |
Assessing immunity to rubella virus: A plea for standardization of IgG (immuno)assays
Bouthry E , Furione M , Huzly D , Ogee-Nwankwo A , Hao L , Adebayo A , Icenogle J , Sarasini A , Revello MG , Grangeot-Keros L , Vauloup-Fellous C . J Clin Microbiol 2016 54 (7) 1720-1725 BACKGROUND: Immunity to rubella virus (RV) is commonly determined by measuring specific immunoglobulin G (RV-IgG). However, RV-IgG results and their interpretation may vary depending on the immunoassay even though most commercial imunoassays (CIAs) have been calibrated against an international standard and results are reported in international units per milliliter (IU/mL). METHODS: A panel of 322 sera collected from pregnant women that pretested negative or equivocal for RV-IgG in a prior test (routine screening) was selected. This panel was tested with two reference tests, immunoblot (IB) and neutralization (Nt), and with 8 CIAs widely used in Europe. RESULTS: IB and Nt gave concordant results on 267/322 (82.9%) sera. Of these, 85 (26.4%) sera were negative and 182 (56.5%) sera were positive for both tests. All 85 IB/Nt-negative samples were classified as negative with all CIAs. Of the 182 IB/Nt-positive samples, 25.3% to 61.5% were classified as equivocal and 6% to 64.8% were classified as positive with the CIAs. Wide variations in IU/ml titers were observed. CONCLUSIONS: In our series, more than half the women considered susceptible to RV based on CIA results, tested positive for RV antibodies by IB/Nt. Our data suggest that: i) sensitivity of CIAs could be increased by considering equivocal results as positive, and ii) the definition of immunity to RV as the 10 IU/mL usual cut-off as well as the use of quantitative results for clinical decisions may warrant reconsideration. A better standardization of CIAs for RV IgG determination is needed. |
Collection and laboratory methods for dried blood spots for hemoglobin A1c and total and high-density lipoprotein cholesterol in population based surveys
Miller IM , Lacher DA , Chen TC , Zipf GW , Gindi RM , Galinsky AM , Nwankwo T , Terry AL . Clin Chim Acta 2015 445 143-54 BACKGROUND: The Health Measures at Home Study was a study designed to evaluate the feasibility of incorporating dried blood spots (DBS) collection into the National Health Interview Survey and to compare the proficiencies between field interviewers and health technicians in obtaining DBS. METHODS: DBS collection and venipuncture were attempted on 125 participants. The DBS were collected in the participant's home and venous blood was collected in the National Health and Nutrition Examination Survey (NHANES) mobile examination center. The DBS results were compared to venous results in the NHANES for the measurements of hemoglobin A1c (HbA1c) and total and high-density lipoprotein (HDL) cholesterol. RESULTS: Field interviewers and health technicians were able to collect the DBS for greater than 95% of participants. For DBS, health technicians and field interviewers were highly correlated for HbA1c (r=0.92) and total cholesterol (r=0.89), but not for HDL cholesterol (r=0.72). The DBS results of interviewers and health technicians compared to the venous method for HbA1c (r=0.90), but did not compare well for HDL cholesterol (r=0.64-0.66) and total cholesterol (r=0.65-0.67). CONCLUSION: DBS was comparable to venous HbA1c, but not for total and HDL cholesterol. Health technicians and field interviewers had similar performance for DBS methods, except HDL cholesterol. |
Validating prediction equations for mid-arm circumference measurements in adults: National Health and Nutrition Examination Survey, 2001-2012
Nwankwo T , Ostchega Y , Zhang G , Hughes JP . Blood Press Monit 2015 20 (3) 157-63 BACKGROUND: Accurate measurement of blood pressure (BP) requires choosing an appropriate BP cuff size. OBJECTIVES: The objective of this study was to examine the validity of regression equations to predict mid-arm circumference (mid-AC) using 2001-2012 National Health and Nutrition Examination Survey height and weight data. METHODS: National Health and Nutrition Examination Survey uses a complex multistage probability sample design to represent the civilian, noninstitutionalized US resident population. The sample consisted of 29 745 participants aged 20 years and older. RESULTS: For both men and women, the correlations between the predicted and measured mid-AC values were as follows: r=0.91 and 0.92, P<0.001, respectively. For both sexes, the difference between the predicted and measured mid-AC mean values was less than 1.5 cm. The overall percent agreement for selecting the appropriate BP cuff, using the American Heart Association cuff size criteria and comparing the predicted mid-AC values with measured values, was 83.0% for men and 80.0% for women. The percent agreement for small adult cuff was 10.0% for men and 54.0% for women; for adult cuff it was 87.0% for men and 88.0% for women; for large adult cuff it was 82.0% for men and 80.0% for women; and for thigh cuff it was 84.0% for men and 74.0% for women. All agreement statistics were above chance (for men, gamma=0.96, and Kendall's Tau-b=0.73; for women, gamma=0.97, and Kendall's Tau-b=0.76). CONCLUSION: When possible, mid-AC should be directly measured for appropriate BP cuffing; however, the results of this validation study suggest that the prediction equations for mid-AC estimations were highly correlated and had an overall 80.0% agreement with measured mid-AC. |
Trends in blood pressure among adults with hypertension: United States, 2003 to 2012
Yoon SS , Gu Q , Nwankwo T , Wright JD , Hong Y , Burt V . Hypertension 2014 65 (1) 54-61 The aim of this study is to describe trends in the awareness, treatment, and control of hypertension; mean blood pressure; and the classification of blood pressure among US adults 2003 to 2012. Using data from the National Health and Nutrition Examination Survey 2003 to 2012, a total of 9255 adult participants aged ≥18 years were identified as having hypertension, defined as measured blood pressure ≥140/90 mm Hg or taking prescription medication for hypertension. Awareness and treatment among hypertensive adults were ascertained via an interviewer administered questionnaire. Controlled hypertension among hypertensive adults was defined as systolic blood pressure <140 mm Hg and diastolic blood pressure <90 mm Hg. Blood pressure was categorized as optimal blood pressure, prehypertension, and stage I and stage II hypertension. Between 2003 and 2012, the percentage of adults with controlled hypertension increased (P-trend <0.01). Hypertensive adults with optimal blood pressure and with prehypertension increased from 13% to 19% and 27% to 33%, respectively (P-trend <0.01 for both groups). Among hypertensive adults who were taking antihypertensive medication, uncontrolled hypertension decreased from 38% to 30% (P-trend <0.01). Similarly, a decrease in mean systolic blood pressure was observed (P-trend <0.01); however, mean diastolic blood pressure remained unchanged. The trend in the control of blood pressure has improved among hypertensive adults resulting in a higher percentage with blood pressure at the optimal or prehypertension level and a lower percentage in stage I and stage II hypertension. Overall, mean systolic blood pressure decreased as did the prevalence of uncontrolled hypertension among the treated hypertensive population. |
High-throughput assay optimization and statistical interpolation of rubella-specific neutralizing antibody titers
Lambert ND , Pankratz VS , Larrabee BR , Ogee-Nwankwo A , Chen MH , Icenogle JP , Poland GA . Clin Vaccine Immunol 2014 21 (3) 340-6 Rubella remains a social and economic burden due to the high incidence of congenital rubella syndrome (CRS) in some countries. For this reason, an accurate and efficient high-throughput measure of antibody response to vaccination is an important tool. In order to measure rubella-specific neutralizing antibodies in a large cohort of vaccinated individuals, a high-throughput immunocolorimetric system was developed. Statistical interpolation models were applied to the resulting titers to refine quantitative estimates of neutralizing antibody titers relative to the assayed neutralizing antibody dilutions. This assay, including the statistical methods developed, can be used to assess the neutralizing humoral immune response to rubella virus and may be adaptable for assessing the response to other viral vaccines and infectious agents. |
Mid-arm circumference and recommended blood pressure cuffs for children and adolescents aged between 3 and 19 years: data from the National Health and Nutrition Examination Survey, 1999-2010
Ostchega Y , Hughes JP , Prineas RJ , Zhang G , Nwankwo T , Chiappa MM . Blood Press Monit 2014 19 (1) 26-31 BACKGROUND: Accurately measuring blood pressure (BP) requires choosing an appropriate BP cuff size. OBJECTIVES: This study examined trends in mid-arm circumference (mid-AC) and in the distribution of appropriate BP cuffs using 1999-2010 National Health and Nutrition Examination Survey (NHANES) data. METHODS: NHANES uses a complex multistage probability sample design to select participants who are representative of the entire civilian, noninstitutionalized US population. The analytic sample consisted of 21 350 participants aged between 3 and 19 years at the time of examination. The mean mid-AC and the percentage of children requiring recommended BP cuff sizes were analyzed across survey years and by sex, age, race/ethnicity, and age-specific and sex-specific BMI categories. RESULTS: During NHANES 1999-2010, the overall trend in mean mid-AC in cm for boys and girls was not significant. During NHANES 2007-2010, 24% of boys aged between 9 and 11 years, 53% of boys aged between 12 and 15 years, and 89% of boys aged between 16 and 19 years required a standard adult cuff or larger to be cuffed correctly. Corresponding estimates for girls were 22, 48, and 57%, respectively. During NHANES 2007-2010, 30.4% of obese boys and 24.3% of obese girls required a large adult cuff and 2.1% of obese boys and 0.9% of obese girls required a thigh cuff for appropriate cuffing. CONCLUSION: During NHANES 2007-2010, 20% of boys and girls as young as 9-11 years required a standard adult cuff to be cuffed appropriately. In addition, approximately one-third of obese participants required adult large BP cuffs to be cuffed appropriately. |
Mean mid-arm circumference and blood pressure cuff sizes for US adults: National Health and Nutrition Examination Survey, 1999-2010
Ostchega Y , Hughes JP , Zhang G , Nwankwo T , Chiappa MM . Blood Press Monit 2013 18 (3) 138-43 BACKGROUND: Accurately measuring blood pressure (BP) requires choosing an appropriate BP cuff size. OBJECTIVES: This study examined trends in mid-arm circumference (mid-AC) and distribution of BP cuff sizes using 1999-2002, 2003-2006, and 2007-2010 National Health and Nutrition Examination Survey (NHANES) data. METHODS: NHANES uses a complex multistage probability sample design to select participants who are representative of the entire civilian, noninstitutionalized US population. The analytic sample consisted of 28 233 participants aged 20 years or older. Mid-AC and BP cuff sizes were analyzed across survey years by sex, age, race/ethnicity, hypertension, and diabetic status. RESULTS: Data from NHANES 2007-2010 show that the mean mid-AC for men was 34.2 cm and for women was 31.9 cm. Men showed a significant trend in mid-AC (from 33.9 cm in 1999-2002 to 34.2 cm in 2007-2010; P<0.05 for trend). In addition, 42.9% of men and 25.3% of women needed a large adult BP cuff and 1.9% of men and 2.8% of women needed thigh cuffs to be appropriately cuffed. Moreover, 52% of hypertensive men, 38% of hypertensive women, 59.1% of diabetic men, and 53.6% of diabetic women required the use of BP cuffs with sizes different from those of standard adult-sized BP cuffs for accurate BP measurement. CONCLUSION: There was an overall significant trend in the mean mid-AC in cm for men but not for women. On the basis of NHANES 2007-2010 data, approximately 45% of adult men and approximately 28% of adult women required the use of BP cuffs with sizes different from those of standard adult-sized BP cuffs for accurate BP measurement. |
Resting pulse rate reference data for children, adolescents, and adults: United States, 1999-2008
Ostchega Y , Porter KS , Hughes J , Dillon CF , Nwankwo T . Natl Health Stat Report 2011 (41) 1-16 OBJECTIVE: This report presents national reference data on resting pulse rate (RPR), for all ages of the U.S. population, from 1999-2008. METHODS: During 1999-2008, 49,114 persons were examined. From this, a normative sample comprising 35,302 persons was identified as those who did not have a current medical condition or use a medication that would affect the RPR. RPR was obtained after the participant had been seated and had rested quietly for approximately 4 minutes. RESULTS: RPR is inversely associated with age. There is a mean RPR of 129 beats per minute (standard error, or SE, 0.9) at less than age 1 year, which decreases to a mean RPR of 96 beats/min (SE 0.5) by age 5, and further decreases to 78 beats/min (SE 0.3) in early adolescence. The mean RPR in adulthood plateaus at 72 beats/min (SE 0.2) (p < 0.05 for trend). In addition, there is a significant gender difference, with the male pulse rate plateauing in early adulthood, while the female resting pulse plateaus later when middle-aged. There are two exceptions, that is, infants under age 1 year and adults aged 80 and over, when the mean RPR is statistically and significantly higher in females than in males (females under age 20 have an RPR of 90 beats/min, SE 0.3, and males under age 20 have an RPR of 86 beats/min, SE 0.3, p <0.05; females aged 20 and over have an RPR of 74 beats/min, SE 0.2, and males aged 20 and over have an RPR of 71 beats/min, SE 0.3, p <0.05). After controlling for age effects, non-Hispanic black males have a significantly (p <0.001) lower mean RPR (74 beats/min) than non-Hispanic white males (77 beats/min) and Mexican-American males (76 beats/min). Among females, non-Hispanic black females (79 beats/min) and Mexican-American females (79 beats/min) had statistically and significantly (p < 0.01) lower mean RPRs compared with non-Hispanic white females (80 beats/min). Among males, the prevalence of clinically defined tachycardia (abnormally fast heart rate, RPR 100 beats/min) is 1.3% (95% CI = 1.1-1.7), and the prevalence of clinically defined bradycardia (abnormally slow heart rate, RPR < 60 beats/min) is 15.2% (95% CI = 14.1-16.4). For adult females, these prevalences are 1.9% (95% CI = 1.6-2.3) for clinical tachycardia and 6.9% (95% CI = 6.2-7.8) for clinical bradycardia. Controlling for age, males have higher odds (2.43, 95% CI = 2.09-2.83) of having bradycardia, and notably lower odds (0.71, 95% CI = 0.52-0.97) of having tachycardia than women. CONCLUSIONS: The data provides current, updated population-based percentiles of RPR, which is one of the key vital signs routinely measured in clinical practice. |
Mean systolic and diastolic blood pressure in adults aged 18 and over in the United States, 2001-2008
Wright JD , Hughes JP , Ostchega Y , Yoon SS , Nwankwo T . Natl Health Stat Report 2011 (35) 1-22, 24 OBJECTIVE: This report presents estimates for the period 2001-2008 of means and selected percentiles of systolic and diastolic blood pressure by sex, race or ethnicity, age, and hypertension status in adults aged 18 and over. METHODS: Demographic characteristics were collected during a personal interview, and blood pressures were measured during a physician examination. All estimates were calculated using the mean of up to three measurements. The final analytic sample consisted of 19,921 adults aged 18 and over with complete data. Examined sample weights and sample design variables were used to calculate nationally representative estimates and standard error estimates that account for the complex design, using SAS and SUDAAN statistical software. RESULTS: Mean systolic blood pressure was 122 mm Hg for all adults aged 18 and over; it was 116 mm Hg for normotensive adults, 130 mm Hg for treated hypertensive adults, and 146 mm Hg for untreated hypertensive adults. Mean diastolic blood pressure was 71 mm Hg for all adults 18 and over; it was 69 mm Hg for normotensive adults, 75 mm Hg for treated hypertensive adults, and 85 mm Hg for untreated hypertensive adults. There was a trend of increasing systolic blood pressure with increasing age. A more curvilinear trend was seen in diastolic blood pressure, with increasing then decreasing means with age in both men and women. Men had higher mean systolic and diastolic pressures than women. There were some differences in mean blood pressure by race or ethnicity, with non-Hispanic black adults having higher mean systolic and diastolic blood pressures than non-Hispanic white and Mexican-American adults, but these differences were not consistent after stratification by hypertension status and sex. CONCLUSIONS: These estimates of the distribution of blood pressure may be useful for policy makers who are considering ways to achieve a downward shift in the population distribution of blood pressure with the goal of reducing morbidity and mortality related to hypertension. |
Assessing blood pressure accuracy of an aneroid sphygmomanometer in a national survey environment
Ostchega Y , Prineas RJ , Nwankwo T , Zipf G . Am J Hypertens 2010 24 (3) 322-7 BACKGROUND: The "gold standard" employed for obtaining blood pressure (BP) for all the National Health and Nutrition Examination Surveys (NHANES) has been the mercury sphygmomanometer (HgS). Because of environmental concerns, there is a need to explore an alternative to HgS. METHODS: We compared the accuracy of the Welch Allyn 767 wall aneroid sphygmomanometer (AnS) to the HgS in children and adults and by BP cuff sizes. Each participant had three BP measurements per device recorded sequentially. The order of the devices and observer were random. A total of 727 individuals participating in the NHANES participated in the study. RESULTS: The mean AnS readings were not statistically significantly different from those of the HgS with the exception of systolic BP (SBP) in aged 8-17 years (mean difference 1.10, s.d. 4.87). There were no statistically significantly different by BP cuff sizes. Agreement for the prevalence of hypertension (BP ≥140 systolic or diastolic ≥90 mm Hg) was above chance (kappa = 0. 81; sensitivity = 81%; specificity = 98%) with AnS readings underestimating by 1.66% (18.33 vs. 20%, P > 0.05) compared to the HgS reading. CONCLUSIONS: With the exception of SBP in ages 8-17 years, the AnS device readings were not significantly different from HgS readings by age or BP cuff sizes selection. Agreement for hypertension classification is good. An accurate and well-calibrated AnS could therefore provide an acceptable alternative to the use of a HgS in surveys, although with appropriate caution given the 81% sensitivity with regard to hypertension thresholds that was observed.American Journal of Hypertension (2010). doi:10.1038/ajh.2010.232. |
Assessing the validity of the Omron HEM-907XL oscillometric blood pressure measurement device in a National Survey environment
Ostchega Y , Nwankwo T , Sorlie PD , Wolz M , Zipf G . J Clin Hypertens (Greenwich) 2010 12 (1) 22-8 Blood pressure (BP) readings taken by Omron HEM-907XL were compared with the results obtained using sphygmomanometer (HgS) in 509 individuals using 2002 Association for the Advancement of Medical Instrumentation (AAMI) criteria. With the exception of diastolic BP in youth ages 13 to 19 years (mean difference, -1.77 mm Hg; standard deviation, 8.65), the Omron device met the criteria. Agreement for hypertension (BP >or=140/90 mm Hg) was above chance (kappa=0.68) and, compared with HgS, Omron underestimated the prevalence of hypertension by 2.65%. The Omron and HgS measurements were highly correlated (r=0.94 for systolic BP and r=0.83 for diastolic BP). Both increased systolic and diastolic BP decreased device agreement (beta-coefficient=-0.10872, P<.0001; beta-coefficient=-0.25981, P<.0001, respectively). The Omron device meets AAMI criteria with the exception of diastolic BP in youth ages 13 to 19 years. However, Omron underestimated the prevalence of hypertension and device agreement decreases with increased systolic and diastolic BP. |
- Page last reviewed:Feb 1, 2024
- Page last updated:Jan 13, 2025
- Content source:
- Powered by CDC PHGKB Infrastructure