Last data update: Aug 15, 2025. (Total: 49733 publications since 2009)
| Records 1-3 (of 3 Records) |
| Query Trace: Mowla SJ[original query] |
|---|
| Ehrlichiosis and Anaplasmosis among Transfusion and Transplant Recipients in the United States
Mowla SJ , Drexler NA , Cherry CC , Annambholta PD , Kracalik IT , Basavaraju SV . Emerg Infect Dis 2021 27 (11) 2768-2775 Ehrlichiosis and anaplasmosis are emerging tickborne diseases that can also be transmitted through blood transfusions or organ transplants. Since 2000, ehrlichiosis and anaplasmosis cases in the United States have increased substantially, resulting in potential risk to transplant and transfusion recipients. We reviewed ehrlichiosis and anaplasmosis cases among blood transfusion and solid organ transplant recipients in the United States from peer-reviewed literature and Centers for Disease Control and Prevention investigations. We identified 132 cases during 1997-2020, 12 transfusion-associated cases and 120 cases in transplant recipients; 8 cases were donor-derived, and in 13 cases illness occurred <1 year after transplant. Disease in the remaining 99 cases occurred ≥1 year after transplant, suggesting donor-derived disease was unlikely. Severe illness or death were reported among 15 transfusion and transplant recipients. Clinicians should be alert for these possible infections among transfusion and transplant recipients to prevent severe complications or death by quickly treating them. |
| Supplemental findings of the 2019 National Blood Collection and Utilization Survey
Mowla SJ , Sapiano MRP , Jones JM , Berger JJ , Basavaraju SV . Transfusion 2021 61 Suppl 2 S11-S35 INTRODUCTION: Supplemental data from the 2019 National Blood Collection and Utilization Survey (NBCUS) are presented and include findings on donor characteristics, autologous and directed donations and transfusions, platelets (PLTs), plasma and granulocyte transfusions, pediatric transfusions, transfusion-associated adverse events, cost of blood units, hospital policies and practices, and implementation of blood safety measures, including pathogen reduction technology (PRT). METHODS: National estimates were produced using weighting and imputation methods for a number of donors, donations, donor deferrals, autologous and directed donations and transfusions, PLT and plasma collections and transfusions, a number of crossmatch procedures, a number of units irradiated and leukoreduced, pediatric transfusions, and transfusion-associated adverse events. RESULTS: Between 2017 and 2019, there was a slight decrease in successful donations by 1.1%. Donations by persons aged 16-18 decreased by 10.1% while donations among donors >65 years increased by 10.5%. From 2017 to 2019, the median price paid for blood components by hospitals for leukoreduced red blood cell units, leukoreduced apheresis PLT units, and for fresh frozen plasma units continued to decrease. The rate of life-threatening transfusion-related adverse reactions continued to decrease. Most whole blood/red blood cell units (97%) and PLT units (97%) were leukoreduced. CONCLUSION: Blood donations decreased between 2017 and 2019. Donations from younger donors continued to decline while donations among older donors have steadily increased. Prices paid for blood products by hospitals decreased. Implementation of PRT among blood centers and hospitals is slowly expanding. |
| A Comparison of Transfusion-Related Adverse Reactions Among Apheresis Platelets, Whole Blood-Derived Platelets, and Platelets Subjected to Pathogen Reduction Technology as Reported to the National Healthcare Safety Network Hemovigilance Module
Mowla SJ , Kracalik IT , Sapiano MRP , O'Hearn L , Andrzejewski CJr , Basavaraju SV . Transfus Med Rev 2021 35 (2) 78-84 Despite advances in transfusion safety, concerns with safety of platelet transfusions remain including platelet-related sepsis and higher reaction rates observed among patients receiving apheresis platelets (APLTs). National Healthcare Safety Network (NHSN) Hemovigilance Module (HM) data were analyzed to quantify the burden and severity of adverse reactions occurring from APLTs and whole blood-derived platelets (WBD-PLTs). Facilities participating in NHSN HM during 2010-2018 were included. Adverse reaction rates (number per 100,000 components transfused) were calculated for APLTs and WBD-PLTs stratified by severity, use of platelet additive solution (PAS), and pathogen reduction technology (PRT). Chi-square tests were used to compare rates. During the study interval, 2,000,589 platelets were transfused: 1,435,154 APLTs; 525,902 WBD-PLTs; and among APLTs, 39,533 PRT-APLTs. APLT adverse reaction rates were higher (478 vs 70/ 100,000, P< .01) and more often serious (34 vs 6/100,000; P< .01) compared with WBD-PLTs. Adverse reactions were higher among PRT-APLTs (572/100,000) and were less often serious (18/100,000) compared with non-PRT-APLTs (35/100,000) although this association was not statistically significant. Among components implicated in adverse reactions, 92% of APLTs were suspended in plasma. Compared with PRT-APLTs stored in PAS, rates were higher among units stored in plasma (760 vs 525/100,000). Most serious reactions (75%) were allergic. No transfusion-transmitted infections were reported among PRT-APLTs. APLTs were associated with a 6-fold and 2-fold higher serious adverse reaction risks compared with WBD-PLTs and PRT-APLTs, respectively. These findings demonstrate the importance of monitoring transfusion-related adverse reactions to track the safety of platelet transfusions and quantify the impact of mitigation strategies through national hemovigilance systems. |
- Page last reviewed:Feb 1, 2024
- Page last updated:Aug 15, 2025
- Content source:
- Powered by CDC PHGKB Infrastructure


