Last data update: Mar 21, 2025. (Total: 48935 publications since 2009)
Records 1-10 (of 10 Records) |
Query Trace: Martin SBJr[original query] |
---|
Potential for exposure to particles and gases throughout vat photopolymerization additive manufacturing processes
Bowers LN , Stefaniak AB , Knepp AK , LeBouf RF , Martin SBJr , Ranpara AC , Burns DA , Virji MA . Buildings (Basel) 2022 12 (8) Vat photopolymerization (VP), a type of additive manufacturing process that cures resin to build objects, can emit potentially hazardous particles and gases. We evaluated two VP technologies, stereolithography (SLA) and digital light processing (DLP), in three separate environmental chambers to understand task-based impacts on indoor air quality. Airborne particles, total volatile organic compounds (TVOCs), and/or specific volatile organic compounds (VOCs) were monitored during each task to evaluate their exposure potential. Regardless of duration, all tasks released particles and organic gases, though concentrations varied between SLA and DLP processes and among tasks. Maximum particle concentrations reached 1200 #/cm3 and some aerosols contained potentially hazardous elements such as barium, chromium, and manganese. TVOC concentrations were highest for the isopropyl alcohol (IPA) rinsing, soaking, and drying post-processing tasks (up to 36.8 mg/m3), lowest for the resin pouring pre-printing, printing, and resin recovery post-printing tasks (up to 0.1 mg/m3), and intermediate for the curing post-processing task (up to 3 mg/m3). Individual VOCs included, among others, the potential occupational carcinogen acetaldehyde and the immune sensitizer 2-hydroxypropyl methacrylate (pouring, printing, recovery, and curing tasks). Careful consideration of all tasks is important for the development of strategies to minimize indoor air pollution and exposure potential from VP processes. © 2022 by the authors. |
Ventilation Improvement Strategies Among K-12 Public Schools - The National School COVID-19 Prevention Study, United States, February 14-March 27, 2022.
Pampati S , Rasberry CN , McConnell L , Timpe Z , Lee S , Spencer P , Moore S , Mead KR , Murray CC , Deng X , Iachan R , Tripathi T , Martin SBJr , Barrios LC . MMWR Morb Mortal Wkly Rep 2022 71 (23) 770-775 Effective COVID-19 prevention in kindergarten through grade 12 (K-12) schools requires multicomponent prevention strategies in school buildings and school-based transportation, including improving ventilation (1). Improved ventilation can reduce the concentration of infectious aerosols and duration of potential exposures (2,3), is linked to lower COVID-19 incidence (4), and can offer other health-related benefits (e.g., better measures of respiratory health, such as reduced allergy symptoms) (5). Whereas ambient wind currents effectively dissipate SARS-CoV-2 (the virus that causes COVID-19) outdoors,* ventilation systems provide protective airflow and filtration indoors (6). CDC examined reported ventilation improvement strategies among a nationally representative sample of K-12 public schools in the United States using wave 4 (February 14-March 27, 2022) data from the National School COVID-19 Prevention Study (NSCPS) (420 schools), a web-based survey administered to school-level administrators beginning in summer 2021.(†) The most frequently reported ventilation improvement strategies were lower-cost strategies, including relocating activities outdoors (73.6%), inspecting and validating existing heating, ventilation and air conditioning (HVAC) systems (70.5%), and opening doors (67.3%) or windows (67.2%) when safe to do so. A smaller proportion of schools reported more resource-intensive strategies such as replacing or upgrading HVAC systems (38.5%) or using high-efficiency particulate air (HEPA) filtration systems in classrooms (28.2%) or eating areas (29.8%). Rural and mid-poverty-level schools were less likely to report several resource-intensive strategies. For example, rural schools were less likely to use portable HEPA filtration systems in classrooms (15.6%) than were city (37.7%) and suburban schools (32.9%), and mid-poverty-level schools were less likely than were high-poverty-level schools to have replaced or upgraded HVAC systems (32.4% versus 48.8%). Substantial federal resources to improve ventilation in schools are available.(§) Ensuring their use might reduce SARS-CoV-2 transmission in schools. Focusing support on schools least likely to have resource-intensive ventilation strategies might facilitate equitable implementation of ventilation improvements. |
Case study: efficacy of engineering controls in mitigating diacetyl and 2,3-pentanedione emissions during coffee grinding
Stanton ML , McClelland TL , Beaty M , Ranpara A , Martin SBJr . Front Public Health 2022 10 750289 Exposure to elevated levels of diacetyl in flavoring and microwave popcorn production has been associated with respiratory impairment among workers including from a severe lung disease known as obliterative bronchiolitis. Laboratory studies demonstrate damage to the respiratory tract in rodents exposed to either diacetyl or the related alpha-diketone 2,3-pentanedione. Respiratory tract damage includes the development of obliterative bronchiolitis-like changes in the lungs of rats repeatedly inhaling either diacetyl or 2,3-pentanedione. In one flavored coffee processing facility, current workers who spent time in higher diacetyl and 2,3-pentanedione areas had lower lung function values, while five former flavoring room workers were diagnosed with obliterative bronchiolitis. In that and other coffee roasting and packaging facilities, grinding roasted coffee beans has been identified as contributing to elevated levels of diacetyl and 2,3-pentanedione. To reduce worker exposures, employers can take various actions to control exposures according to the hierarchy of controls. Because elimination or substitution is not applicable to coffee production facilities not using flavorings, use of engineering controls to control exposures at their source is especially important. This work demonstrates the use of temporary ventilated enclosures around grinding equipment in a single coffee roasting and packaging facility to mitigate diacetyl and 2,3-pentanedione emissions from grinding equipment to the main production space. Concentrations of diacetyl and 2,3-pentanedione were measured in various locations throughout the main production space as well as inside and outside of ventilated enclosures to evaluate the effect of the enclosures on exposures. Diacetyl and 2,3-pentanedione concentrations outside one grinder enclosure decreased by 95 and 92%, respectively, despite ground coffee production increasing by 12%, after the enclosure was installed. Outside a second enclosure, diacetyl and 2,3-pentanedione concentrations both decreased 84%, greater than the 33% decrease in ground coffee production after installation. Temporary ventilated enclosures used as engineering control measures in this study effectively reduced emissions of diacetyl and 2,3-pentanedione at the source in this facility. These findings motivated management to explore options with a grinding equipment manufacturer to permanently ventilate their grinders to reduce emissions of diacetyl and 2,3-pentanedione. |
Efficacy of Ventilation, HEPA Air Cleaners, Universal Masking, and Physical Distancing for Reducing Exposure to Simulated Exhaled Aerosols in a Meeting Room.
Coyle JP , Derk RC , Lindsley WG , Blachere FM , Boots T , Lemons AR , Martin SBJr , Mead KR , Fotta SA , Reynolds JS , McKinney WG , Sinsel EW , Beezhold DH , Noti JD . Viruses 2021 13 (12) There is strong evidence associating the indoor environment with transmission of SARS-CoV-2, the virus that causes COVID-19. SARS-CoV-2 can spread by exposure to droplets and very fine aerosol particles from respiratory fluids that are released by infected persons. Layered mitigation strategies, including but not limited to maintaining physical distancing, adequate ventilation, universal masking, avoiding overcrowding, and vaccination, have shown to be effective in reducing the spread of SARS-CoV-2 within the indoor environment. Here, we examine the effect of mitigation strategies on reducing the risk of exposure to simulated respiratory aerosol particles within a classroom-style meeting room. To quantify exposure of uninfected individuals (Recipients), surrogate respiratory aerosol particles were generated by a breathing simulator with a headform (Source) that mimicked breath exhalations. Recipients, represented by three breathing simulators with manikin headforms, were placed in a meeting room and affixed with optical particle counters to measure 0.3-3 µm aerosol particles. Universal masking of all breathing simulators with a 3-ply cotton mask reduced aerosol exposure by 50% or more compared to scenarios with simulators unmasked. While evaluating the effect of Source placement, Recipients had the highest exposure at 0.9 m in a face-to-face orientation. Ventilation reduced exposure by approximately 5% per unit increase in air change per hour (ACH), irrespective of whether increases in ACH were by the HVAC system or portable HEPA air cleaners. The results demonstrate that mitigation strategies, such as universal masking and increasing ventilation, reduce personal exposure to respiratory aerosols within a meeting room. While universal masking remains a key component of a layered mitigation strategy of exposure reduction, increasing ventilation via system HVAC or portable HEPA air cleaners further reduces exposure. |
Efficacy of Portable Air Cleaners and Masking for Reducing Indoor Exposure to Simulated Exhaled SARS-CoV-2 Aerosols - United States, 2021.
Lindsley WG , Derk RC , Coyle JP , Martin SBJr , Mead KR , Blachere FM , Beezhold DH , Brooks JT , Boots T , Noti JD . MMWR Morb Mortal Wkly Rep 2021 70 (27) 972-976 SARS-CoV-2, the virus that causes COVID-19, can be spread by exposure to droplets and aerosols of respiratory fluids that are released by infected persons when they cough, sing, talk, or exhale. To reduce indoor transmission of SARS-CoV-2 between persons, CDC recommends measures including physical distancing, universal masking (the use of face masks in public places by everyone who is not fully vaccinated), and increased room ventilation (1). Ventilation systems can be supplemented with portable high efficiency particulate air (HEPA) cleaners* to reduce the number of infectious particles in the air and provide enhanced protection from transmission between persons (2); two recent reports found that HEPA air cleaners in classrooms could reduce overall aerosol particle concentrations by ≥80% within 30 minutes (3,4). To investigate the effectiveness of portable HEPA air cleaners and universal masking at reducing exposure to exhaled aerosol particles, the investigation team used respiratory simulators to mimic a person with COVID-19 and other, uninfected persons in a conference room. The addition of two HEPA air cleaners that met the Environmental Protection Agency (EPA)-recommended clean air delivery rate (CADR) (5) reduced overall exposure to simulated exhaled aerosol particles by up to 65% without universal masking. Without the HEPA air cleaners, universal masking reduced the combined mean aerosol concentration by 72%. The combination of the two HEPA air cleaners and universal masking reduced overall exposure by up to 90%. The HEPA air cleaners were most effective when they were close to the aerosol source. These findings suggest that portable HEPA air cleaners can reduce exposure to SARS-CoV-2 aerosols in indoor environments, with greater reductions in exposure occurring when used in combination with universal masking. |
Factors That Might Affect SARS-CoV-2 Transmission Among Foreign-Born and U.S.-Born Poultry Facility Workers - Maryland, May 2020.
Rubenstein BL , Campbell S , Meyers AR , Crum DA , Mitchell CS , Hutson J , Williams DL , Senesie SS , Gilani Z , Reynolds S , Alba B , Tavitian S , Billings K , Saintus L , Martin SBJr , Mainzer H . MMWR Morb Mortal Wkly Rep 2020 69 (50) 1906-1910 Numerous recent assessments indicate that meat and poultry processing facility workers are at increased risk for infection with SARS-CoV-2, the virus that causes coronavirus disease 2019 (COVID-19) (1-4). Physical proximity to other workers and shared equipment can facilitate disease transmission in these settings (2-4). The disproportionate number of foreign-born workers employed in meat and poultry processing reflects structural, social, and economic inequities that likely contribute to an increased COVID-19 incidence in this population* (5). In May 2020, the Maryland Department of Health and CDC investigated factors that might affect person-to-person SARS-CoV-2 transmission among persons who worked at two poultry processing facilities. A survey administered to 359 workers identified differences in risk factors for SARS-CoV-2 infection between workers born outside the United States and U.S.-born workers. Compared with U.S.-born workers, foreign-born workers had higher odds of working in fixed locations on the production floor (odds ratio [OR] for cutup and packaging jobs = 4.8), of having shared commutes (OR = 1.9), and of living with other poultry workers (OR = 6.0). They had lower odds of participating in social gatherings (OR for visits to family = 0.2; OR for visits to friends = 0.4), and they visited fewer businesses in the week before the survey than did their U.S.-born coworkers. Some workplace risk factors can be mitigated through engineering and administrative controls focused on the production floor, and this will be of particular benefit to the foreign-born workers concentrated in these areas. Employers and health departments can also partner with local organizations to disseminate culturally and linguistically tailored messages about risk reduction behaviors in community settings, including shared transportation(§) and household members dwelling in close quarters. |
Inactivation of the multi-drug resistant pathogen Candida auris using ultraviolet germicidal irradiation (UVGI)
Lemons AR , McClelland TL , Martin SBJr , Lindsley WG , Green BJ . J Hosp Infect 2020 BACKGROUND: Candida auris, often a multi-drug resistant fungal pathogen, has become an emerging threat in healthcare settings around the world. Reliable disinfection protocols specifically designed to inactivate C. auris are essential, as many chemical disinfectants commonly used in healthcare settings have been shown to have variable efficacy at inactivating C. auris. AIM: Ultraviolet germicidal irradiation (UVGI) was investigated as a method to inactivate clinically relevant strains of C. auris. METHODS: Ten C. auris and two C. albicans isolates were exposed to ultraviolet (UV) energy to determine the UV dose required to inactivate each isolate. Using a UV reactor, each isolate (10(6) cells/mL) was exposed to 11 UV doses ranging from 10-150 mJ/cm(2) and then cultured to assess cell viability. FINDINGS: An exponential decay model was applied to each dose-response curve to determine inactivation rate constants for each isolate, which ranged from 0.108-0.176 cm(2)/mJ for C. auris and 0.239-0.292 cm(2)/mJ for C. albicans. As the model of exponential decay did not accurately estimate the dose beyond 99.9% inactivation, a logistic regression model was applied to better estimate the doses required for 99.999% inactivation. Using this model, significantly greater UV energy was required to inactivate C. auris (103 to 192 mJ/cm(2)) when compared to C. albicans (78 to 80 mJ/cm(2)). CONCLUSION: This study demonstrated UVGI as a feasible approach for inactivating C. auris, although variable susceptibility among isolates must be taken into account. This dose-response data is critical for recommending UVGI dosing strategies to be tested in healthcare settings. |
Efficacy of an ambulance ventilation system in reducing EMS worker exposure to airborne particles from a patient cough aerosol simulator
Lindsley WG , Blachere FM , McClelland TL , Neu DT , Mnatsakanova A , Martin SBJr , Mead KR , Noti JD . J Occup Environ Hyg 2019 16 (12) 1-13 The protection of emergency medical service (EMS) workers from airborne disease transmission is important during routine transport of patients with infectious respiratory illnesses and would be critical during a pandemic of a disease such as influenza. However, few studies have examined the effectiveness of ambulance ventilation systems at reducing EMS worker exposure to airborne particles (aerosols). In our study, a cough aerosol simulator mimicking a coughing patient with an infectious respiratory illness was placed on a patient cot in an ambulance. The concentration and dispersion of cough aerosol particles were measured for 15 min at locations corresponding to likely positions of an EMS worker treating the patient. Experiments were performed with the patient cot at an angle of 0 degrees (horizontal), 30 degrees , and 60 degrees , and with the ambulance ventilation system set to 0, 5, and 12 air changes/hour (ACH). Our results showed that increasing the air change rate significantly reduced the airborne particle concentration (p < 0.001). Increasing the air change rate from 0 to 5 ACH reduced the mean aerosol concentration by 34% (SD = 19%) overall, while increasing it from 0 to 12 ACH reduced the concentration by 68% (SD = 9%). Changing the cot angle also affected the concentration (p < 0.001), but the effect was more modest, especially at 5 and 12 ACH. Contrary to our expectations, the aerosol concentrations at the different worker positions were not significantly different (p < 0.556). Flow visualization experiments showed that the ventilation system created a recirculation pattern which helped disperse the aerosol particles throughout the compartment, reducing the effectiveness of the system. Our findings indicate that the ambulance ventilation system reduced but did not eliminate worker exposure to infectious aerosol particles. Aerosol exposures were not significantly different at different locations within the compartment, including locations behind and beside the patient. Improved ventilation system designs with smoother and more unidirectional airflows could provide better worker protection. |
Evaluation of emissions and exposures at workplaces using desktop 3-dimensional printers
Stefaniak AB , Johnson AR , du Preez S , Hammond DR , Wells JR , Ham JE , LeBouf RF , Menchaca KW , Martin SBJr , Duling MG , Bowers LN , Knepp AK , Su FC , de Beer DJ , du Plessis JL . J Chem Health Saf 2019 26 (2) 19-30 There is a paucity of data on additive manufacturing process emissions and personal exposures in real-world workplaces. Hence, we evaluated atmospheres in four workplaces utilizing desktop "3-dimensional" (3-d) printers [fused filament fabrication (FFF) and sheer] for production, prototyping, or research. Airborne particle diameter and number concentration and total volatile organic compound concentrations were measured using real-time instruments. Airborne particles and volatile organic compounds were collected using time-integrated sampling techniques for off-line analysis. Personal exposures for metals and volatile organic compounds were measured in the breathing zone of operators. All 3-d printers that were monitored released ultrafine and fine particles and organic vapors into workplace air. Particle number-based emission rates (#/min) ranged from 9.4 times 109 to 4.4 times 1011 (n = 9 samples) for FFF 3-d printers and from 1.9 to 3.8 times 109 (n = 2 samples) for a sheer 3-d printer. The large variability in emission rate values reflected variability from the printers as well as differences in printer design, operating conditions, and feedstock materials among printers. A custom-built ventilated enclosure evaluated at one facility was capable of reducing particle number and total organic chemical concentrations by 99.7% and 53.2%, respectively. Carbonyl compounds were detected in room air; however, none were specifically attributed to the 3-d printing process. Personal exposure to metals (aluminum, iron) and 12 different organic chemicals were all below applicable NIOSH Recommended Exposure Limit values, but results are not reflective of all possible exposure scenarios. More research is needed to understand 3- d printer emissions, exposures, and efficacy of engineering controls in occupational settings. |
3-dimensional printing with nano-enabled filaments releases polymer particles containing carbon nanotubes into air
Stefaniak AB , Bowers LN , Knepp AK , Virji MA , Birch EM , Ham JE , Wells JR , Qi C , Schwegler-Berry D , Friend S , Johnson AR , Martin SBJr , Qian Y , LeBouf RF , Birch Q , Hammond D . Indoor Air 2018 28 (6) 840-851 Fused deposition modeling (FDM() ) 3-dimensional printing uses polymer filament to build objects. Some polymer filaments are formulated with additives, though it is unknown if they are released during printing. Three commercially-available filaments that contained carbon nanotubes (CNTs) were printed with a desktop FDM() 3-D printer in a chamber while monitoring total particle number concentration and size distribution. Airborne particles were collected on filters and analyzed using electron microscopy. Carbonyl compounds were identified by mass spectrometry. The elemental carbon content of the bulk CNT-containing filaments was 1.5 to 5.2 wt%. CNT-containing filaments released up to 10(10) ultrafine (d <100 nm) particles/g printed and 10(6) to 10(8) respirable (d ~0.5 to 2 mum) particles/g printed. From microscopy, 1% of the emitted respirable polymer particles contained visible CNTs. Carbonyl emissions were observed above the limit of detection (LOD) but were below the limit of quantitation (LOQ). Modeling indicated that for all filaments, the average proportional lung deposition of CNT-containing polymer particles was 6.5%, 5.7%, and 7.2% for the head airways, tracheobronchiolar, and pulmonary regions, respectively. If CNT-containing polymer particles are hazardous, it would be prudent to control emissions during use of these filaments. This article is protected by copyright. All rights reserved. |
- Page last reviewed:Feb 1, 2024
- Page last updated:Mar 21, 2025
- Content source:
- Powered by CDC PHGKB Infrastructure