Last data update: May 12, 2025. (Total: 49248 publications since 2009)
Records 1-30 (of 88 Records) |
Query Trace: Lindsley M[original query] |
---|
Developing a method to estimate aerosol generation during poultry slaughtering and defeathering in Bangladesh: An experimental study
Rimi NA , Fahad MH , Clark A , Sultana R , Hossain K , Saifullah MK , Shanta IS , Swayne DE , Hassan MZ , Mortaza SMG , Swarna ST , Giasuddin M , LeBoa C , Rahman MS , Biswas D , Rahman M , Kile JC , Kennedy ED , Lindsley WG . Build Environ 2025 271 Influenza viruses can be aerosolized when slaughtering infected chickens, which increases the risk of zoonotic transmission. We conducted pilot experiments to measure the concentrations of airborne particles <2.5 µm during slaughtering and defeathering of chickens to help identify methods that can minimize workers’ exposure to potentially hazardous aerosol particles. By using two types of airborne particle monitors stationed at different heights and angles in a controlled environment, we measured aerosolized particulate matters during exsanguination of 10 slaughtered chickens and use of a mechanical device for defeathering 10 chickens. For the slaughtering experiments, the median particle concentrations at 148 cm height were 67 µg/m3 (IQR 44–121) with a baseline count 10 µg/m3 (IQR 10–10) for the Particle and Temperature Sensor + (PATS+) monitors and 34 µg/m3 (IQR 34–64) with a baseline count 25 µg/m3 (IQR 16–44) for the SidePak™ monitor. For the defeathering experiments, the median particle concentrations recorded by the PATS+ monitors were not significantly different between 148 cm (41 µg/m3, IQR 29–49; baseline 12 µg/m3, IQR 10–19) and 107 cm height (37 µg/m3, IQR 29–44; baseline 13 µg/m3, IQR 10–22). Our protocol can be used to test the generation of airborne particles that are <2.5 µm during different slaughtering and defeathering techniques used in the live bird markets to identify procedures that produce the lowest concentrations of small aerosol particles. © 2025 |
Human and canine blastomycosis cases associated with riverside neighborhood, Wisconsin, USA, December 2021-March 2022(1)
Segaloff HE , Wu K , Williams SL , Shaw S , Miko S , Parnell LA , Hanzlicek AS , Carlson KM , Lindsley M , Westergaard RP , Toda M , Gibbons-Burgener SN . Emerg Infect Dis 2024 30 (12) 2633-2638 We investigated a blastomycosis cluster among humans and canines in a neighborhood in Wisconsin, United States. We conducted interviews and collected serum specimens for Blastomyces antibody testing by enzyme immunoassay. Although no definitive exposure was identified, evidence supports potential exposures from the riverbank, riverside trails or yards, or construction dust. |
Testing for blastomycosis, coccidioidomycosis, and histoplasmosis at a major commercial laboratory, United States, 2019-2024
Benedict K , Williams SL , Smith DJ , Lindsley MD , Lockhart SR , Toda M . Open Forum Infect Dis 2024 11 (8) ofae448 BACKGROUND: Blastomycosis, coccidioidomycosis, and histoplasmosis are environmentally acquired fungal diseases that clinically resemble bacterial and viral community-acquired pneumonia and require laboratory testing for diagnosis. Patients frequently present to primary care and experience diagnostic delays when a fungal etiology is not initially suspected. Current national-level public health surveillance for these diseases is limited and does not include laboratory data, so nationwide testing practices are unknown. METHODS: We identified laboratory tests for blastomycosis, coccidioidomycosis, and histoplasmosis ordered during 1 March 2019-29 February 2024 and performed within a major national commercial laboratory system. We analyzed test results, patient and healthcare provider features, reasons for testing, and temporal trends. RESULTS: Results included 5693 Blastomyces complement fixation tests (of those, 12% were positive), 71 858 immunodiffusion tests (0.1% positive), and 1186 serum enzyme immunoassay (EIA) tests (11% positive); 154 989 Coccidioides EIA immunoglobulin M results (5% positive) and 154 968 immunoglobulin G results (8% positive); and 46 346 Histoplasma complement fixation tests (30% positive), 49 062 immunodiffusion tests (1% positive), 35 506 serum EIA tests (4% positive), and 82 489 urine EIA tests (2% positive). Most histoplasmosis (58%-74%) and blastomycosis (42%-68%) tests were ordered from hospitals, whereas coccidioidomycosis tests were most frequently ordered by primary care providers (40%). A yearly average of 2727 positive tests were ordered by healthcare providers in states without public health surveillance for these diseases. CONCLUSIONS: Blastomycosis, coccidioidomycosis, and histoplasmosis are likely underdetected in primary care settings or by public health surveillance. Increased testing by primary care providers and expanded surveillance are needed to reduce disease burden. |
Efficacy of powered air purifying respirators (PAPRs) for source control of simulated respiratory aerosols
Lindsley WG , Blachere FM , Derk RC , Mnatsakanova A , Noti JD . Am J Infect Control 2024 BACKGROUND: Loose-fitting powered air purifying respirators (PAPRs) are a popular alternative to the use of filtering facepiece respirators for healthcare workers. Although PAPRs protect the wearer from aerosol particles, their ability to block infectious aerosol particles exhaled by the wearer from being released into the environment (called source control) is unclear. METHODS: The source control performance of four PAPRs with loose-fitting facepieces were tested using a manikin that exhales aerosol particles. The PAPRs were tested by themselves and in combination with a face-worn product intended to provide source control (either a surgical mask or an N95® filtering facepiece respirator.) RESULTS: Two PAPR facepieces with filtration panels significantly reduced the release of exhaled aerosols into the environment, while three facepieces without such panels did not. Wearing a surgical mask or respirator under the facepiece significantly improved the source control performance. CONCLUSIONS: Most PAPR facepieces do not block aerosols exhaled by the wearer. Facepieces designed to filter exhaled particles can prevent aerosols from being released into the environment. Wearing a surgical mask or a filtering facepiece respirator under the facepiece can also provide source control, but PAPRs are not typically certified for use with masks and respirators. |
Detection of fungal DNA in human body fluids and tissues during a multistate outbreak of fungal meningitis and other infections.
Gade L , Scheel CM , Pham CD , Lindsley MD , Iqbal N , Cleveland AA , Whitney AM , Lockhart SR , Brandt ME , Litvintseva AP . Eukaryot Cell 2013 12 (5) 677-83 ![]() Exserohilum rostratum was the major cause of an outbreak of fungal infections linked to injections of contaminated methylprednisolone acetate. Because almost 14,000 persons were exposed to product that was possibly contaminated with multiple fungal pathogens, there was unprecedented need for a rapid throughput diagnostic test that could detect both E. rostratum and other unusual agents of fungal infection. Here we report development of a novel PCR test that allowed for rapid and specific detection of fungal DNA in cerebrospinal fluid (CSF), other body fluids and tissues of infected individuals. The test relied on direct purification of free-circulating fungal DNA from fluids and subsequent PCR amplification and sequencing. Using this method, we detected Exserohilum rostratum DNA in 123 samples from 114 case-patients (28% of 413 case-patients for whom 627 samples were available), and Cladosporium DNA in one sample from one case-patient. PCR with novel Exserohilum-specific ITS-2 region primers detected 25 case-patients with samples that were negative using broad-range ITS primers. Compared to fungal culture, this molecular test was more sensitive: of 139 case-patients with an identical specimen tested by culture and PCR, E. rostratum was recovered in culture from 19 (14%), but detected by PCR in 41 (29%), showing a diagnostic sensitivity of 29% for PCR compared to 14% for culture in this patient group. The ability to rapidly confirm the etiologic role of E. rostratum in these infections provided an important contribution in the public health response to this outbreak. |
Reduction of exposure to simulated respiratory aerosols using ventilation, physical distancing, and universal masking (preprint)
Coyle JP , Derk RC , Lindsley WG , Boots T , Blachere FM , Reynolds JS , McKinney WG , Sinsel EW , Lemons AR , Beezhold DH , Noti JD . medRxiv 2021 2021.09.16.21263702 To limit community spread of SARS-CoV-2, CDC recommends universal masking indoors, maintaining 1.8 m of physical distancing, adequate ventilation, and avoiding crowded indoor spaces. Several studies have examined the independent influence of each control strategy in mitigating transmission in isolation, yet controls are often implemented concomitantly within an indoor environment. To address the influence of physical distancing, universal masking, and ventilation on very fine respiratory droplets and aerosol particle exposure, a simulator that coughed and exhaled aerosols (the source) and a second breathing simulator (the recipient) were placed in an exposure chamber. When controlling for the other two mitigation strategies, universal masking with 3-ply cotton masks reduced exposure to 0.3–3 µm coughed and exhaled aerosol particles by > 77% compared to unmasked tests, whereas physical distancing (0.9 or 1.8 m) significantly changed exposure to cough but not exhaled aerosols. The effectiveness of ventilation depended upon the respiratory activity, i.e., coughing or breathing, as well as the duration of exposure time. Our results demonstrate that a combination of administrative and engineering controls can reduce personal inhalation exposure to potentially infectious very fine respiratory droplets and aerosol particles within an indoor environment.PRACTICAL IMPLICATIONSUniversal masking provided the most effective strategy in reducing inhalational exposure to simulated aerosols.Physical distancing provided limited reductions in exposure to small aerosol particles.Ventilation promotes air mixing in addition to aerosol removal, thus altering the exposure profile to individuals.A combination of mitigation strategies can effectively reduce exposure to potentially infectious aerosols.Competing Interest StatementThe authors have declared no competing interest.Funding StatementThis work was supported by the Centers for Disease Control and Prevention Emergency Operations Center.Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:Not ApplicableAll necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesThe datasets generated during and/or analyzed during the current study are available from the corresponding author on reasonable request. |
Efficacy of universal masking for source control and personal protection from simulated cough and exhaled aerosols in a room (preprint)
Lindsley WG , Beezhold DH , Coyle J , Derk RC , Blachere FM , Boots T , Reynolds JS , McKinney WG , Sinsel E , Noti JD . medRxiv 2021 2021.04.21.21255880 Face masks reduce the spread of infectious respiratory diseases such as COVID-19 by blocking aerosols produced during coughs and exhalations (“source control”). Masks also slow and deflect cough and exhalation airflows, which changes the dispersion of aerosols. Factors such as the directions in which people are facing (orientation) and separation distance also affect aerosol dispersion. However, it is not clear how masking, orientation, and distance interact. We placed a respiratory aerosol simulator (“source”) and a breathing simulator (“recipient”) in a 3 m x 3 m chamber and measured aerosol concentrations for different combinations of masking, orientation, and separation distance. When the simulators were front-to-front during coughing, masks reduced the 15-minute mean aerosol concentration at the recipient by 92% at 0.9 and 1.8 m separation. When the simulators were side-by-side, masks reduced the concentration by 81% at 0.9 m and 78% at 1.8 m. During breathing, masks reduced the aerosol concentration by 66% when front-to-front and 76% when side-by-side at 0.9 m. Similar results were seen at 1.8 m. When the simulators were unmasked, changing the orientations from front-to-front to side-by-side reduced the cough aerosol concentration by 59% at 0.9 m and 60% at 1.8 m. When both simulators were masked, changing the orientations did not significantly change the concentration at either distance during coughing or breathing. Increasing the distance between the simulators from 0.9 m to 1.8 m during coughing reduced the aerosol concentration by 25% when no masks were worn but had little effect when both simulators were masked. During breathing, when neither simulator was masked, increasing the separation reduced the concentration by 13%, which approached significance, while the change was not significant when both source and recipient were masked. Our results show that universal masking reduces exposure to respiratory aerosol particles regardless of the orientation and separation distance between the source and recipient.Competing Interest StatementThe authors have declared no competing interest.Clinical TrialRegistration not requiredFunding StatementThis work was supported by the US Centers for Disease Control and Prevention (CDC).Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:IRB approval was not required for this study.All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesExperimental data is available upon request. |
Face mask fit modifications that improve source control performance (preprint)
Blachere FM , Lemons AR , Coyle JP , Derk RC , Lindsley WG , Beezhold DH , Woodfork K , Duling MG , Boutin B , Boots T , Harris JR , Nurkiewicz T , Noti JD . medRxiv 2021 2021.09.16.21263642 BACKGROUND During the COVID-19 pandemic, face masks are used as source control devices to reduce the expulsion of respiratory aerosols from infected people. Modifications such as mask braces, earloop straps, knotting and tucking, and double masking have been proposed to improve mask fit. However, the data on source control are limited.METHODS The effectiveness of mask fit modifications was determined by conducting fit tests on human subjects and simulator manikins and by performing simulated coughs and exhalations using a source control measurement system.RESULTS Medical masks without modification blocked ≥56% of cough aerosols and ≥42% of exhaled aerosols. Modifying fit by crossing the earloops or placing a bracket under the mask did not increase performance, while using earloop toggles, an earloop strap, and knotting and tucking the mask increased performance. The most effective modifications for improving source control performance were double masking and using a mask brace. Placing a cloth mask over a medical mask blocked ≥85% of cough aerosols and ≥91% of exhaled aerosols. Placing a brace over a medical mask blocked ≥95% of cough aerosols and ≥99% of exhaled aerosols.CONCLUSION Fit modifications can greatly improve the performance of face masks as source control devices for respiratory aerosols.Competing Interest StatementThe authors have declared no competing interest.Funding StatementResearch was supported by the following sources: Centers for Disease Control and Prevention, National Institutes of Health R01 ES015022 (TRN) and WV-CTSI U54 GM104942-05.Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:WVU Protocol #: 2009119037All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesData is available from research personnel upon request. |
Efficacy of face masks, neck gaiters and face shields for reducing the expulsion of simulated cough-generated aerosols (preprint)
Lindsley WG , Blachere FM , Law BF , Beezhold DH , Noti JD . medRxiv 2020 2020.10.05.20207241 Face masks are recommended to reduce community transmission of SARS-CoV-2. One of the primary benefits of face masks and other coverings is as source control devices to reduce the expulsion of respiratory aerosols during coughing, breathing, and speaking. Face shields and neck gaiters have been proposed as an alternative to face masks, but information about face shields and neck gaiters as source control devices is limited. We used a cough aerosol simulator with a pliable skin headform to propel small aerosol particles (0 to 7 µm) into different face coverings. An N95 respirator blocked 99% of the cough aerosol, a medical grade procedure mask blocked 59%, a 3-ply cotton cloth face mask blocked 51%, and a polyester neck gaiter blocked 47% as a single layer and 60% when folded into a double layer. In contrast, the face shield blocked 2% of the cough aerosol. Our results suggest that face masks and neck gaiters are preferable to face shields as source control devices for cough aerosols.Competing Interest StatementThe authors have declared no competing interest.Funding StatementThis research was funded by the National Institute for Occupational Safety and Health (NIOSH), US Centers for Disease Control and Prevention (CDC).Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:No IRB approval requiredAll necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesExperimental data is available upon request. |
A comparison of performance metrics for cloth face masks as source control devices for simulated cough and exhalation aerosols (preprint)
Lindsley WG , Blachere FM , Beezhold DH , Law BF , Derk RC , Hettick JM , Woodfork K , Goldsmith WT , Harris JR , Duling MG , Boutin B , Nurkiewicz T , Noti JD . medRxiv 2021 Universal mask wearing is recommended by the Centers for Disease Control and Prevention to help control the spread of COVID-19. Masks reduce the expulsion of respiratory aerosols (called source control) and offer some protection to the wearer. However, masks vary greatly in their designs and construction materials, and it is not clear which are most effective. Our study tested 15 reusable cloth masks (which included face masks, neck gaiters, and bandanas), two medical masks, and two N95 filtering facepiece respirators as source control devices for aerosols ≤ 7 µm produced during simulated coughing and exhalation. These measurements were compared with the mask filtration efficiencies, airflow resistances, and fit factors. The source control collection efficiencies for the cloth masks ranged from 17% to 71% for coughing and 35% to 66% for exhalation. The filtration efficiencies of the cloth masks ranged from 1.4% to 98%, while the fit factors were 1.3 to 7.4 on an elastomeric manikin headform and 1.0 to 4.0 on human test subjects. The correlation coefficients between the source control efficacies and the other performance metrics ranged from 0.31 to 0.66 and were significant in all but one case. However, none of the alternative metrics were strong predictors of the source control performance of cloth masks. Our results suggest that a better understanding of the relationships between source control performance and metrics like filtration efficiency, airflow resistance, and fit factor are needed to develop simple methods to estimate the effectiveness of masks as source control devices for respiratory aerosols. |
Tackling histoplasmosis infection in people living with HIV from Latin America: From diagnostic strategy to public health solutions
Cáceres DH , Gómez BL , Tobón Á M , Restrepo Á , Chiller T , Lindsley MD , Meis JF , Verweij PE . J Fungi (Basel) 2023 9 (5) Histoplasmosis, caused by the thermally dimorphic fungus Histoplasma spp., is a disease with a broad clinical spectrum, presenting from asymptomatic/flu-like symptoms to progressive disseminated disease in people with immunosuppression. In recent years, the concept of histoplasmosis as a disease restricted to the American continent has changed, as now histoplasmosis is reported in many regions around the world. In Latin America, histoplasmosis represents a threat, especially in people with advanced HIV disease (AHD). Diagnosis of histoplasmosis in people living with HIV (PLHIV) is challenging due to the low index of suspicion of the disease, non-specificity of signs and symptoms, and limited access to specific laboratory testing, while the diagnostic delay is significantly associated with mortality. In the last decade, novel diagnostic tests have been developed for the rapid detection of histoplasmosis, such as commercial kits for antigen detection. Furthermore, advocacy groups were created that presented histoplasmosis as a public health problem, with emphasis on patients at risk of progressive disseminated disease. This review aims to discuss the impact of histoplasmosis associated with AHD in Latin America and the strategies employed to tackle histoplasmosis, from the implementation of laboratory testing to disease advocacy and public health interventions. |
Constant vs. cyclic flow when testing face masks and respirators as source control devices for simulated respiratory aerosols
Lindsley WG , Blachere FM , Derk RC , Boots T , Duling MG , Boutin B , Beezhold DH , Noti JD . Aerosol Sci Technol 2023 57 (3) 215-232 SARS-CoV-2 spreads by infectious aerosols and droplets from the respiratory tract. Masks and respirators can reduce the transmission of infectious respiratory diseases by collecting these aerosols at the source. The ability of source control devices to block aerosols can be tested by expelling an aerosol through a headform using constant airflows, which are simpler, or cyclic airflows, which are more realistic but require more complex methods. Experiments with respirators found that using cyclic vs. constant flows affected the amount of aerosol inhaled, but similar comparisons have not been made for source control devices with exhaled aerosols. We measured the collection efficiencies for exhaled aerosols for two cloth masks, two medical masks with and without an elastic mask brace, a neck gaiter, and an N95 filtering facepiece respirator using 15 L/min and 85 L/min constant and cyclic flows and a headform with pliable skin. The collection efficiencies for the 15 L/min cyclic flow, 15 L/min constant flow, and 85 L/min constant flow were not significantly different in most cases. The apparent collection efficiencies for the 85 L/min cyclic flow were artificially increased by rebreathing and refiltration of the aerosol from the collection chamber. The collection efficiencies correlated well with the fit factors (rho > 0.95) but not the filtration efficiencies (rho < 0.54). Our results suggest that the aerosol collection efficiency measurements of source control devices are comparable when testing the devices using either constant or cyclic airflows and that the potential for aerosol rebreathing must be considered when conducting experiments.Copyright © This work was authored as part of the Contributor's official duties as an Employee of the United States Government and is therefore a work of the United States Government. In accordance with 17 USC. 105, no copyright protection is available for such works under US Law. |
Validation and concordance analysis of a new lateral flow assay for detection of histoplasma antigen in urine
Cáceres DH , Gómez BL , Tobón Á M , Minderman M , Bridges N , Chiller T , Lindsley MD . J Fungi (Basel) 2021 7 (10) Histoplasmosis is a major cause of mortality in people living with HIV (PLHIV). Rapid methods to diagnose Histoplasma capsulatum disease could dramatically decrease the time to initiate treatment, resulting in reduced mortality. The aim of this study was to validate a MiraVista(®) Diagnostics (MVD) Histoplasma urine antigen lateral flow assay (MVD LFA) for the detection of H. capsulatum antigen (Ag) in urine and compare this LFA against the MVista(®) Histoplasma Ag quantitative enzyme immunoassays (MVD EIA). We assessed the MVD LFA using a standardized reference panel of urine specimens from Colombia. We tested 100 urine specimens, 26 from PLHIV diagnosed with histoplasmosis, 42 from PLHIV with other infectious diseases, and 32 from non-HIV infected persons without histoplasmosis. Sensitivity and specificity of the MVD LFA was 96%, compared with 96% sensitivity and 77% specificity of the MVD EIA. Concordance analysis between MVD LFA and the MVD EIA displayed an 84% agreement, and a Kappa of 0.656. The MVD LFA evaluated in this study has several advantages, including a turnaround time for results of approximately 40 min, no need for complex laboratory infrastructure or highly trained laboratory personnel, use of urine specimens, and ease of performing. |
SARS-CoV-2 Reduction in Shared Indoor Air-Reply.
Dowell D , Lindsley WG , Brooks JT . JAMA 2022 328 (21) 2163-2164 In response to our recent Viewpoint1 on air quality interventions to reduce SARS-CoV-2 transmission, Mr Srikrishna and colleagues note that a clear target for air changes per hour in non–health care settings would be helpful. Although we are not aware of COVID-19 outbreaks resulting from SARS-CoV-2 exposure in spaces ventilated with 5 to 6 air changes per hour or less, there are minimal data available on this association to date.2 Further study is needed to determine the effectiveness of various air changes per hour under different circumstances. For some scenarios, higher air changes per hour might be needed to prevent transmission. For example, the CDC recommends at least 12 air changes per hour for hospital airborne infection isolation rooms and for some other patient care areas in health care settings.3 |
Fungal pathogens as causes of acute respiratory illness in hospitalized veterans: Frequency of fungal positive test results using rapid immunodiagnostic assays
Caceres DH , Rodriguez-Barradas MC , Whitaker M , Jackson BR , Kim L , Surie D , Cikesh B , Lindsley MD , McCotter OZ , Berkow EL , Toda M . J Fungi (Basel) 2023 9 (4) Fungal respiratory illnesses caused by endemic mycoses can be nonspecific and are often mistaken for viral or bacterial infections. We performed fungal testing on serum specimens from patients hospitalized with acute respiratory illness (ARI) to assess the possible role of endemic fungi as etiologic agents. Patients hospitalized with ARI at a Veterans Affairs hospital in Houston, Texas, during November 2016-August 2017 were enrolled. Epidemiologic and clinical data, nasopharyngeal and oropharyngeal samples for viral testing (PCR), and serum specimens were collected at admission. We retrospectively tested remnant sera from a subset of patients with negative initial viral testing using immunoassays for the detection of Coccidioides and Histoplasma antibodies (Ab) and Cryptococcus, Aspergillus, and Histoplasma antigens (Ag). Of 224 patient serum specimens tested, 49 (22%) had positive results for fungal pathogens, including 30 (13%) by Coccidioides immunodiagnostic assays, 19 (8%) by Histoplasma immunodiagnostic assays, 2 (1%) by Aspergillus Ag, and none by Cryptococcus Ag testing. A high proportion of veterans hospitalized with ARI had positive serological results for fungal pathogens, primarily endemic mycoses, which cause fungal pneumonia. The high proportion of Coccidioides positivity is unexpected as this fungus is not thought to be common in southeastern Texas or metropolitan Houston, though is known to be endemic in southwestern Texas. Although serological testing suffers from low specificity, these results suggest that these fungi may be more common causes of ARI in southeast Texas than commonly appreciated and more increased clinical evaluation may be warranted. |
Efficacy of Do-It-Yourself air filtration units in reducing exposure to simulated respiratory aerosols
Derk RC , Coyle JP , Lindsley WG , Blachere FM , Lemons AR , Service SK , Martin SB Jr , Mead KR , Fotta SA , Reynolds JS , McKinney WG , Sinsel EW , Beezhold DH , Noti JD . Build Environ 2023 229 109920 Many respiratory diseases, including COVID-19, can be spread by aerosols expelled by infected people when they cough, talk, sing, or exhale. Exposure to these aerosols indoors can be reduced by portable air filtration units (air cleaners). Homemade or Do-It-Yourself (DIY) air filtration units are a popular alternative to commercially produced devices, but performance data is limited. Our study used a speaker-audience model to examine the efficacy of two popular types of DIY air filtration units, the Corsi-Rosenthal cube and a modified Ford air filtration unit, in reducing exposure to simulated respiratory aerosols within a mock classroom. Experiments were conducted using four breathing simulators at different locations in the room, one acting as the respiratory aerosol source and three as recipients. Optical particle spectrometers monitored simulated respiratory aerosol particles (0.3-3 μm) as they dispersed throughout the room. Using two DIY cubes (in the front and back of the room) increased the air change rate as much as 12.4 over room ventilation, depending on filter thickness and fan airflow. Using multiple linear regression, each unit increase of air change reduced exposure by 10%. Increasing the number of filters, filter thickness, and fan airflow significantly enhanced the air change rate, which resulted in exposure reductions of up to 73%. Our results show DIY air filtration units can be an effective means of reducing aerosol exposure. However, they also show performance of DIY units can vary considerably depending upon their design, construction, and positioning, and users should be mindful of these limitations. |
Comparison of immunodiagnostic assays for the rapid diagnosis of coccidioidomycosis in dogs
Caceres DH , Lindsley MD . J Fungi (Basel) 2022 8 (7) Coccidioidomycosis is a disease caused by the dimorphic fungi Coccidioides spp., which affects humans and a variety of animal species, including domestic dogs. In dogs, accurate diagnosis could provide a substantial improvement on the quality of canine life, as well as an advancement in the mapping of regions endemic for coccidioidomycosis. The purpose of this study was to compare immunodiagnostic assays for anti-Coccidioides antibody (Ab) detection in dogs' serum. Three commercially available immunodiagnostic assays (IMMY(); Norman, OK, USA) were evaluated, including the sna Coccidioides Ab Lateral Flow Assay (LFA), Coccidioides IDCF immunodiffusion assay (IDCF), and the Clarus Coccidioides Ab Enzyme Immunoassay (EIA). Assays were evaluated using 98 dog serum samples: 29 from dogs with coccidioidomycosis, 15 from dogs diagnosed with histoplasmosis, 10 from dogs diagnosed with blastomycosis, and 44 from dogs without a fungal disease. Using specimens from dogs with coccidioidomycosis, the IDCF had an accuracy of 92% (95% confidence interval [95% CI] = 85-96%), the EIA had an accuracy of 91% (95% CI = 83-96%), and the LFA displayed an accuracy of 82% (95% CI = 73-89%). Using Kappa analysis, the agreement between LFA and EIA was 0.59 (95% CI = 0.42-0.75), that between LFA and IDCF was 0.64 (95% CI = 0.48-0.79), and that between EIA and IDCF was 0.79 (95% CI = 0.64-0.90). Most cross-reactions were observed in dogs with histoplasmosis. Compared with EIA and IDCF, the LFA requires substantially less laboratory equipment and infrastructure and rapidly produces results, offering a substantial improvement for the initial screening of coccidioidomycosis in dogs. |
Reducing SARS-CoV-2 in Shared Indoor Air.
Dowell D , Lindsley WG , Brooks JT . JAMA 2022 328 (2) 141-142 SARS-CoV-2 replicates in the respiratory tract and spreads through exhalation of infectious respiratory particles. The chances of transmission increase the longer an uninfected person stays in an enclosed space with an infected person. Infection can occur not only through short-range transmission of exhaled respiratory particles from an infectious person resulting in mucous membrane deposition or inhalation of exhaled respiratory particles by an uninfected person. Infection also can occur through long-range transmission from inhalation of infectious respiratory particles that remain suspended in air for longer periods (potentially after the infectious person is no longer present) and across longer distances (greater than a few meters). |
Reduction of exposure to simulated respiratory aerosols using ventilation, physical distancing, and universal masking.
Coyle JP , Derk RC , Lindsley WG , Boots T , Blachere FM , Reynolds JS , McKinney WG , Sinsel EW , Lemons AR , Beezhold DH , Noti JD . Indoor Air 2022 32 (2) e12987 To limit community spread of SARS-CoV-2, CDC recommends universal masking indoors, maintaining 1.8 m of physical distancing, adequate ventilation, and avoiding crowded indoor spaces. Several studies have examined the independent influence of each control strategy in mitigating transmission in isolation, yet controls are often implemented concomitantly within an indoor environment. To address the influence of physical distancing, universal masking, and ventilation on very fine respiratory droplets and aerosol particle exposure, a simulator that coughed and exhaled aerosols (the source) and a second breathing simulator (the recipient) were placed in an exposure chamber. When controlling for the other two mitigation strategies, universal masking with 3-ply cotton masks reduced exposure to 0.3-3 µm coughed and exhaled aerosol particles by >77% compared to unmasked tests, whereas physical distancing (0.9 or 1.8 m) significantly changed exposure to cough but not exhaled aerosols. The effectiveness of ventilation depended upon the respiratory activity, that is, coughing or breathing, as well as the duration of exposure time. Our results demonstrate that a layered mitigation strategy approach of administrative and engineering controls can reduce personal inhalation exposure to potentially infectious very fine respiratory droplets and aerosol particles within an indoor environment. |
Efficacy of Ventilation, HEPA Air Cleaners, Universal Masking, and Physical Distancing for Reducing Exposure to Simulated Exhaled Aerosols in a Meeting Room.
Coyle JP , Derk RC , Lindsley WG , Blachere FM , Boots T , Lemons AR , Martin SBJr , Mead KR , Fotta SA , Reynolds JS , McKinney WG , Sinsel EW , Beezhold DH , Noti JD . Viruses 2021 13 (12) There is strong evidence associating the indoor environment with transmission of SARS-CoV-2, the virus that causes COVID-19. SARS-CoV-2 can spread by exposure to droplets and very fine aerosol particles from respiratory fluids that are released by infected persons. Layered mitigation strategies, including but not limited to maintaining physical distancing, adequate ventilation, universal masking, avoiding overcrowding, and vaccination, have shown to be effective in reducing the spread of SARS-CoV-2 within the indoor environment. Here, we examine the effect of mitigation strategies on reducing the risk of exposure to simulated respiratory aerosol particles within a classroom-style meeting room. To quantify exposure of uninfected individuals (Recipients), surrogate respiratory aerosol particles were generated by a breathing simulator with a headform (Source) that mimicked breath exhalations. Recipients, represented by three breathing simulators with manikin headforms, were placed in a meeting room and affixed with optical particle counters to measure 0.3-3 µm aerosol particles. Universal masking of all breathing simulators with a 3-ply cotton mask reduced aerosol exposure by 50% or more compared to scenarios with simulators unmasked. While evaluating the effect of Source placement, Recipients had the highest exposure at 0.9 m in a face-to-face orientation. Ventilation reduced exposure by approximately 5% per unit increase in air change per hour (ACH), irrespective of whether increases in ACH were by the HVAC system or portable HEPA air cleaners. The results demonstrate that mitigation strategies, such as universal masking and increasing ventilation, reduce personal exposure to respiratory aerosols within a meeting room. While universal masking remains a key component of a layered mitigation strategy of exposure reduction, increasing ventilation via system HVAC or portable HEPA air cleaners further reduces exposure. |
Face mask fit modifications that improve source control performance.
Blachere FM , Lemons AR , Coyle JP , Derk RC , Lindsley WG , Beezhold DH , Woodfork K , Duling MG , Boutin B , Boots T , Harris JR , Nurkiewicz T , Noti JD . Am J Infect Control 2021 50 (2) 133-140 BACKGROUND: During the COVID-19 pandemic, face masks are used as source control devices to reduce the expulsion of respiratory aerosols from infected people. Modifications such as mask braces, earloop straps, knotting and tucking, and double masking have been proposed to improve mask fit however the data on source control are limited. METHODS: The effectiveness of mask fit modifications was determined by conducting fit tests on human subjects and simulator manikins and by performing simulated coughs and exhalations using a source control measurement system. RESULTS: Medical masks without modification blocked ≥56% of cough aerosols and ≥42% of exhaled aerosols. Modifying fit by crossing the earloops or placing a bracket under the mask did not increase performance, while using earloop toggles, an earloop strap, and knotting and tucking the mask increased performance. The most effective modifications for improving source control performance were double masking and using a mask brace. Placing a cloth mask over a medical mask blocked ≥85% of cough aerosols and ≥91% of exhaled aerosols. Placing a brace over a medical mask blocked ≥95% of cough aerosols and ≥99% of exhaled aerosols. CONCLUSIONS: Fit modifications can greatly improve the performance of face masks as source control devices for respiratory aerosols. |
Virus decay rates should not be used to reduce recommended room air clearance times
Lindsley WG , Martin SB , Mead KR , Hammond DR . Infect Control Hosp Epidemiol 2021 43 (12) 1-2 We read with concern the letter by Hurlburt et al Reference Hurlburt, DeKleer and Bryce1 proposing revisions to the recommended room air clearance times for infectious aerosols in healthcare facilities. We believe that the calculations performed to justify the changes are based on flawed assumptions and an erroneous calculation. Experimental data on the survival of airborne SARS-CoV-2 virus and the dynamics of room ventilation do not support their conclusions. |
Sampling for SARS-CoV-2 Aerosols in Hospital Patient Rooms.
Lane MA , Walawender M , Webster AS , Brownsword EA , Ingersoll JM , Miller C , Waggoner J , Uyeki TM , Lindsley WG , Kraft CS . Viruses 2021 13 (12) ![]() ![]() Evidence varies as to how far aerosols spread from individuals infected with SARS-CoV-2 in hospital rooms. We investigated the presence of aerosols containing SARS-CoV-2 inside of dedicated COVID-19 patient rooms. Three National Institute for Occupational Safety and Health BC 251 two-stage cyclone samplers were set up in each patient room for a six-hour sampling period. Samplers were place on tripods, which each held two samplers at various heights above the floor. Extracted samples underwent reverse transcription polymerase chain reaction for selected gene regions of the SARS-CoV-2 virus nucleocapsid. Patient medical data were compared between participants in rooms where virus-containing aerosols were detected and those where they were not. Of 576 aerosols samples collected from 19 different rooms across 32 participants, 3% (19) were positive for SARS-CoV-2, the majority from near the head and foot of the bed. Seven of the positive samples were collected inside a single patient room. No significant differences in participant clinical characteristics were found between patients in rooms with positive and negative aerosol samples. SARS-CoV-2 viral aerosols were detected from the patient rooms of nine participants (28%). These findings provide reassurance that personal protective equipment that was recommended for this virus is appropriate given its spread in hospital rooms. © 2021 by the authors. Licensee MDPI, Basel, Switzerland. |
Evaluation of OIDx Histoplasma Urinary Antigen EIA
Cáceres DH , Gómez BL , Tobón Á M , Chiller TM , Lindsley MD . Mycopathologia 2021 187 (1) 129-131 A sandwich enzyme immunoassay (EIA) for the detection of Histoplasma antigens (Ag) in urine, developed by Optimum Imaging Diagnostics (OIDx) was evaluated. A verification using a standardized reference panel of urine samples found sensitivity of 92%, specificity of 32% and accuracy of 51%. In this study, the OIDx Histoplasma urinary Ag EIA displayed high sensitivity, however, in non-histoplasmosis cases this EIA displayed false-positive results in 68% of specimens tested. |
Efficacy of Portable Air Cleaners and Masking for Reducing Indoor Exposure to Simulated Exhaled SARS-CoV-2 Aerosols - United States, 2021.
Lindsley WG , Derk RC , Coyle JP , Martin SBJr , Mead KR , Blachere FM , Beezhold DH , Brooks JT , Boots T , Noti JD . MMWR Morb Mortal Wkly Rep 2021 70 (27) 972-976 SARS-CoV-2, the virus that causes COVID-19, can be spread by exposure to droplets and aerosols of respiratory fluids that are released by infected persons when they cough, sing, talk, or exhale. To reduce indoor transmission of SARS-CoV-2 between persons, CDC recommends measures including physical distancing, universal masking (the use of face masks in public places by everyone who is not fully vaccinated), and increased room ventilation (1). Ventilation systems can be supplemented with portable high efficiency particulate air (HEPA) cleaners* to reduce the number of infectious particles in the air and provide enhanced protection from transmission between persons (2); two recent reports found that HEPA air cleaners in classrooms could reduce overall aerosol particle concentrations by ≥80% within 30 minutes (3,4). To investigate the effectiveness of portable HEPA air cleaners and universal masking at reducing exposure to exhaled aerosol particles, the investigation team used respiratory simulators to mimic a person with COVID-19 and other, uninfected persons in a conference room. The addition of two HEPA air cleaners that met the Environmental Protection Agency (EPA)-recommended clean air delivery rate (CADR) (5) reduced overall exposure to simulated exhaled aerosol particles by up to 65% without universal masking. Without the HEPA air cleaners, universal masking reduced the combined mean aerosol concentration by 72%. The combination of the two HEPA air cleaners and universal masking reduced overall exposure by up to 90%. The HEPA air cleaners were most effective when they were close to the aerosol source. These findings suggest that portable HEPA air cleaners can reduce exposure to SARS-CoV-2 aerosols in indoor environments, with greater reductions in exposure occurring when used in combination with universal masking. |
Donor-derived Cryptococcus gattii sensu stricto infection in two kidney transplant recipients, southeastern United States
Natarajan P , Lockhart SR , Basavaraju SV , Anjan S , Lindsley MD , McGrath MM , Oh DH , Jackson BR . Am J Transplant 2021 21 (11) 3780-3784 Cryptococcus gattii infection is a rare cause of severe pulmonary disease and meningoencephalitis that has only recently been detected in the southeastern United States. We describe organ transplant-associated outbreak of C. gattii infection involving an HIV-negative immunosuppressed donor in this region who died following new-onset headache and seizure of unknown cause. Retrospective cryptococcal antigen (CrAg) testing of donor serum was positive. Two of three transplant recipients developed severe C. gattii infection 11 and 12 weeks following transplantation. One recipient died from severe pulmonary infection, identified on autopsy, and the other ill recipient survived following treatment for cryptococcal meningitis. This outbreak underscores the importance of considering cryptococcosis in patients with clinical findings suggestive of subacute meningitis or other central nervous system (CNS) pathology, and the potential benefit of routine pre-transplant donor CrAg screening using lateral flow assay to guide recipient antifungal prophylaxis. The case also adds to emerging evidence that C. gattii is a potential threat in the southeastern United States. |
Efficacy of universal masking for source control and personal protection from simulated cough and exhaled aerosols in a room
Lindsley WG , Beezhold DH , Coyle J , Derk RC , Blachere FM , Boots T , Reynolds JS , McKinney WG , Sinsel E , Noti JD . J Occup Environ Hyg 2021 18 (8) 1-15 Face masks reduce the expulsion of respiratory aerosols produced during coughs and exhalations ("source control"). Factors such as the directions in which people are facing (orientation) and separation distance also affect aerosol dispersion. However, it is not clear how the combined effects of masking, orientation, and distance affect the exposure of individuals to respiratory aerosols in indoor spaces. We placed a respiratory aerosol simulator ("source") and a breathing simulator ("recipient") in a 3 m x 3 m chamber and measured aerosol concentrations for different combinations of masking, orientation, and separation distance. When the simulators were front-to-front during coughing, masks reduced the 15-minute mean aerosol concentration at the recipient by 92% at 0.9 and 1.8 m separation. When the simulators were side-by-side, masks reduced the concentration by 81% at 0.9 m and 78% at 1.8 m. During breathing, masks reduced the aerosol concentration by 66% when front-to-front and 76% when side-by-side at 0.9 m. Similar results were seen at 1.8 m. When the simulators were unmasked, changing the orientations from front-to-front to side-by-side reduced the cough aerosol concentration by 59% at 0.9 m and 60% at 1.8 m. When both simulators were masked, changing the orientations did not significantly change the concentration at either distance during coughing or breathing. Increasing the distance between the simulators from 0.9 m to 1.8 m during coughing reduced the aerosol concentration by 25% when no masks were worn but had little effect when both simulators were masked. During breathing, when neither simulator was masked, increasing the separation reduced the concentration by 13%, which approached significance, while the change was not significant when both source and recipient were masked. Our results show that universal masking reduces exposure to respiratory aerosol particles regardless of the orientation and separation distance between the source and recipient. |
A comparison of performance metrics for cloth masks as source control devices for simulated cough and exhalation aerosols.
Lindsley WG , Blachere FM , Beezhold DH , Law BF , Derk RC , Hettick JM , Woodfork K , Goldsmith WT , Harris JR , Duling MG , Boutin B , Nurkiewicz T , Boots T , Coyle J , Noti JD . Aerosol Sci Technol 2021 55 (10) 1125-1142 Universal mask wearing is recommended to help control the spread of COVID-19. Masks reduce the expulsion of aerosols of respiratory fluids into the environment (called source control) and offer some protection to the wearer. Masks are often characterized using filtration efficiency, airflow resistance, and manikin or human fit factors, which are standard metrics used for personal protective devices. However, none of these metrics are direct measurements of how effectively a mask blocks coughed and exhaled aerosols. We studied the source control performance of 15 cloth masks (face masks, neck gaiters, and bandanas), two medical masks, and two N95 filtering facepiece respirators by measuring their ability to block aerosols ≤7 µm expelled during simulated coughing and exhalation (called source control collection efficiency). These measurements were compared with filtration efficiencies, airflow resistances, and fit factors measured on manikin headforms and humans. Collection efficiencies for the cloth masks ranged from 17% to 71% for coughing and 35% to 66% for exhalation. Filtration efficiencies for the cloth masks ranged from 1.4% to 98%, while the fit factors were 1.3 to 7.4 on headforms and 1.0 to 4.0 on human subjects. The Spearman’s rank correlation coefficients between the source control collection efficiencies and the standard metrics ranged from 0.03 to 0.68 and were significant in all but two cases. However, none of the standard metrics were strongly correlated with source control performance. A better understanding of the relationships between source control collection efficiency, filtration efficiency, airflow resistance, and fit factor is needed. ©, This work was authored as part of the Contributor's official duties as an Employee of the United States Government and is therefore a work of the United States Government. In accordance with 17 USC. 105, no copyright protection is available for such works under US Law. |
Surface dosimetry of ultraviolet germicidal irradiation using a colorimetric technique
Neu DT , Mead KR , McClelland TL , Lindsley WG , Martin SB , Heil G , See M , Feng HA . Ann Work Expo Health 2021 65 (5) 605-611 Ultraviolet germicidal irradiation uses ultraviolet C (UV-C) energy to disinfect surfaces in clinical settings. Verifying that the doses of UV-C energy received by surfaces are adequate for proper disinfection levels can be difficult and expensive. Our study aimed to test commercially available colorimetric labels, sensitive to UV-C energy, and compare their precision with an accepted radiometric technique. The color-changing labels were found to predictably change color in a dose-dependent manner that would allow them to act as a qualitative alternative to radiometry when determining the minimum UV-C energy dosage received at surfaces. If deployed using careful protective techniques to avoid unintentional exposure to sunlight or other light sources, the use of colorimetric labels could provide inexpensive, easy, and accurate verification of effective UV-C dosing in clinical spaces. |
Maximizing Fit for Cloth and Medical Procedure Masks to Improve Performance and Reduce SARS-CoV-2 Transmission and Exposure, 2021.
Brooks JT , Beezhold DH , Noti JD , Coyle JP , Derk RC , Blachere FM , Lindsley WG . MMWR Morb Mortal Wkly Rep 2021 70 (7) 254-257 Universal masking is one of the prevention strategies recommended by CDC to slow the spread of SARS-CoV-2, the virus that causes coronavirus disease 2019 (COVID-19) (1). As of February 1, 2021, 38 states and the District of Columbia had universal masking mandates. Mask wearing has also been mandated by executive order for federal property* as well as on domestic and international transportation conveyances.(†) Masks substantially reduce exhaled respiratory droplets and aerosols from infected wearers and reduce exposure of uninfected wearers to these particles. Cloth masks(§) and medical procedure masks(¶) fit more loosely than do respirators (e.g., N95 facepieces). The effectiveness of cloth and medical procedure masks can be improved by ensuring that they are well fitted to the contours of the face to prevent leakage of air around the masks' edges. During January 2021, CDC conducted experimental simulations using pliable elastomeric source and receiver headforms to assess the extent to which two modifications to medical procedure masks, 1) wearing a cloth mask over a medical procedure mask (double masking) and 2) knotting the ear loops of a medical procedure mask where they attach to the mask's edges and then tucking in and flattening the extra material close to the face (knotted and tucked masks), could improve the fit of these masks and reduce the receiver's exposure to an aerosol of simulated respiratory droplet particles of the size considered most important for transmitting SARS-CoV-2. The receiver's exposure was maximally reduced (>95%) when the source and receiver were fitted with modified medical procedure masks. These laboratory-based experiments highlight the importance of good fit to optimize mask performance. Until vaccine-induced population immunity is achieved, universal masking is a highly effective means to slow the spread of SARS-CoV-2** when combined with other protective measures, such as physical distancing, avoiding crowds and poorly ventilated indoor spaces, and good hand hygiene. Innovative efforts to improve the fit of cloth and medical procedure masks to enhance their performance merit attention. |
- Page last reviewed:Feb 1, 2024
- Page last updated:May 12, 2025
- Content source:
- Powered by CDC PHGKB Infrastructure