Last data update: Jun 17, 2024. (Total: 47034 publications since 2009)
Records 1-6 (of 6 Records) |
Query Trace: Lawrence RB [original query] |
---|
Evaluation of total inward leakage for NIOSH-approved elastomeric half-facepiece, full-facepiece, and powered air-purifying respirators using sodium chloride and corn oil aerosols
Rengasamy S , Zhuang Z , Lawrence RB , Boutin B , Yorio P , Horvatin M , McClain C , Harris JR , Coffey C . J Occup Environ Hyg 2021 18 (7) 1-9 Recently, total inward leakage (TIL) for filtering facepiece and elastomeric half-mask respirators (EHRs) was measured according to the International Organization for Standardization (ISO) test method standard 16900-1:2014 that showed larger TIL for corn oil aerosol than for NaCl aerosol. Comparison of TIL measured for different aerosols for higher protection level respirators is lacking. The objective of this study was to determine TIL for EHRs, full-facepiece respirators, and loose-fitting and tight-fitting powered air-purifying respirators (PAPRs) using NaCl and corn oil aerosols to compare. TIL was measured for two models each of EHRs, full-facepiece respirators, and loose-fitting and tight-fitting PAPRs. After fit testing with a PortaCount (TSI, St. Paul, MN) using the Occupational Safety and Health Administration (OSHA) protocol, eight subjects were tested in the NaCl aerosol chamber first and then in the corn oil aerosol chamber, while another eight subjects tested in the reverse order. Subjects were randomly assigned to one of the two groups. TIL was measured as a ratio of mass-based aerosol concentrations inside the mask to the test chamber while the subjects performed ISO 16900-1-defined exercises using continuous sampling methods. The concentration of corn oil aerosol was measured with one light scattering photometer, alternately, and NaCl aerosol was measured using two flame photometers. Results showed the geometric mean TIL for EHR was significantly (p < 0.05) larger for corn oil aerosol than for NaCl aerosol. EHR models equipped with P100 filters showed relatively smaller TIL values than the same models with N95 filters showing that TIL was inversely related to filter efficiency. Interestingly, TIL was significantly (p < 0.05) larger for NaCl aerosol than for corn oil aerosol for PAPRs, but not for full-facepiece respirators. TIL was inversely related to fit factors of respirator types. Overall, filter efficiency and faceseal leakage determine TIL. The relative trends in TIL for the two aerosols' test methods differ between respirator types indicating that generalization of TIL for respirator types may not be appropriate when using different test agents. |
Particle transfer and adherence to human skin compared with cotton glove and pre-moistened polyvinyl alcohol exposure sampling substrates
Stefaniak AB , Wade EE , Lawrence RB , Arnold ED , Virji MA . J Environ Sci Health A Tox Hazard Subst Environ Eng 2021 56 (5) 1-12 Measurement of skin exposure to particles using interception (e.g., cotton gloves) and removal (e.g., wiping) sampling techniques could be inaccurate because these substrates do not have the same topography and adhesion characteristics as skin. The objective of this study was to compare particle transfer and adherence to cotton gloves, cotton gloves with artificial sebum, and a pre-moistened polyvinyl alcohol (PVA) material with bare human skin (fingertip, palm). Experiments were performed with aluminum oxide powder under standardized conditions for three types of surfaces touched, applied loads, contact times, and powder mass levels. In the final mixed model, the fixed effects of substrate, surface type, applied load, and powder mass and their significant two-way interaction terms explained 71% (transfer) and 74% (adherence) of the observed total variance in measurements. For particle mass transfer, compared with bare skin, bias was -77% (cotton glove with sebum) to +197% (PVA material) and for adherence bias ranged from -40% (cotton glove) to +428% (PVA material), which indicated under- and over-sampling by these substrates, respectively. Dermal exposure assessment would benefit from sampling substrates that better reflect human skin characteristics and more accurately estimate exposures. Mischaracterization of dermal exposure has important implications for exposure and risk assessment. |
Assessment of respirator fit capability test criteria for full-facepiece air-purifying respirators
Bergman MS , Zhuang Z , Xu SS , Rengasamy S , Lawrence RB , Boutin B , Harris JR . J Occup Environ Hyg 2019 16 (7) 1-9 An ASTM International subcommittee on Respiratory Protection, F23.65 is currently developing a consensus standard for assessing respirator fit capability (RFC) criteria of half-facepiece air-purifying particulate respirators. The objective of this study was to evaluate if the test methods being developed for half-facepiece respirators can reasonably be applied to nonpowered full-facepiece-air-purifying respirators (FF-APR). Benchmark RFC test data were collected for three families of FF-APRs (a one-size-only family, a two-size family, and a three-size family). All respirators were equipped with P100 class particulate filters. Respirators were outfitted with a sampling probe to collect an in-mask particle concentration sample in the breathing zone of the wearer. Each of the six respirator facepieces was tested on the National Institute for Occupational Safety and Health 25-subject Bivariate Panel. The RFC test assessed face seal leakage using a PortaCount fit test. Subjects followed the corresponding Occupational Safety and Health Administration-accepted fit test protocol. Two donnings per subject/respirator model combination were performed. The panel passing rate (PPR) (number or percentage of subjects in the panel achieving acceptable fit on at least one of two donnings) was determined for each respirator family at specified fit factor passing levels of 500, 1,000, and 2,000. As a reasonable expectation based on a previous analysis of alpha and beta fit test errors for various panel sizes, the selected PPR benchmark for our study was >75%. At the fit factor passing level of 500 obtained on at least one of two donnings, the PPRs for three-, two-, and one-size families were 100, 79, and 88%, respectively. As the fit factor passing criterion increased from 500 to 1,000 or 2,000, PPRs followed a decreasing trend. Each of the three tested families of FF-APRs are capable of fitting >/=75% of the intended user population at the 500 fit factor passing level obtained on at least one of two donnings. The methods presented here can be used as a reference for standards development organizations considering developing RFC test requirements. |
Characterization of chemical contaminants generated by a desktop fused deposition modeling 3-dimensional printer
Stefaniak AB , LeBouf RF , Yi J , Ham J , Nurkewicz T , Schwegler-Berry DE , Chen BT , Wells JR , Duling MG , Lawrence RB , Martin SB Jr , Johnson AR , Virji MA . J Occup Environ Hyg 2017 14 (7) 0 Printing devices are known to emit chemicals into the indoor atmosphere. Understanding factors that influence release of chemical contaminants from printers is necessary to develop effective exposure assessment and control strategies. In this study, a desktop fused deposition modeling (FDM) 3-D printer using acrylonitrile butadiene styrene (ABS) or polylactic acid (PLA) filaments and two monochrome laser printers were evaluated in a 0.5 m3 chamber. During printing, chamber air was monitored for vapors using a real-time photoionization detector (results expressed as isobutylene equivalents) to measure total volatile organic compound (TVOC) concentrations, evacuated canisters to identify specific VOCs by off-line gas chromatography-mass spectrometry (GC-MS) analysis, and liquid bubblers to identify carbonyl compounds by GC-MS. Airborne particles were collected on filters for off-line analysis using scanning electron microscopy with an energy dispersive x-ray detector to identify elemental constituents. For 3-D printing, TVOC emission rates were influenced by a printer malfunction, filament type, and to a lesser extent, by filament color; however, rates were not influenced by the number of printer nozzles used or the manufacturer's provided cover. TVOC emission rates were significantly lower for the 3-D printer (49 to 3552 microg h-1) compared to the laser printers (5782 to 7735 microg h-1). A total of 14 VOCs were identified during 3-D printing that were not present during laser printing. 3-D printed objects continued to off-gas styrene, indicating potential for continued exposure after the print job is completed. Carbonyl reaction products were likely formed from emissions of the 3-D printer, including 4-oxopentanal. Ultrafine particles generated by the 3-D printer using ABS and a laser printer contained chromium. Consideration of the factors that influenced the release of chemical contaminants (including known and suspected asthmagens such as styrene and 4-oxopentanal) from a FDM 3-D printer should be made when designing exposure assessment and control strategies. |
Dermal exposure potential from textiles that contain silver nanoparticles
Stefaniak AB , Duling MG , Lawrence RB , Thomas TA , LeBouf RF , Wade EE , Abbas Virji M . Int J Occup Environ Health 2014 20 (3) 220-234 BACKGROUND: Factors that influence exposure to silver particles from the use of textiles are not well understood. OBJECTIVES: The aim of this study was to evaluate the influence of product treatment and physiological factors on silver release from two textiles. METHODS: Atomic and absorbance spectroscopy, electron microscopy, and dynamic light scattering (DLS) were applied to characterize the chemical and physical properties of the textiles and evaluate silver release in artificial sweat and saliva under varying physiological conditions. One textile had silver incorporated into fiber threads (masterbatch process) and the other had silver nanoparticles coated on fiber surfaces (finishing process). RESULTS: Several complementary and confirmatory analytical techniques (spectroscopy, microscopy, etc.) were required to properly assess silver release. Silver released into artificial sweat or saliva was primarily in ionic form. In a simulated "use" and laundering experiment, the total cumulative amount of silver ion released was greater for the finishing process textile (0.51+/-0.04%) than the masterbatch process textile (0.21+/-0.01%); P<0.01. CONCLUSIONS: We found that the process (masterbatch vs finishing) used to treat textile fibers was a more influential exposure factor than physiological properties of artificial sweat or saliva. |
Release of beryllium from mineral ores in artificial lung and skin surface fluids
Duling MG , Stefaniak AB , Lawrence RB , Chipera SJ , Abbas Virji M . Environ Geochem Health 2011 34 (3) 313-22 Exposure to some manufactured beryllium compounds via skin contact or inhalation can cause sensitization. A portion of sensitized persons who inhale beryllium may develop chronic beryllium disease (CBD). Little is understood about exposures to naturally occurring beryllium minerals. The purpose of this study was to assess the bioaccessibility of beryllium from bertrandite ore. Dissolution of bertrandite from two mine pits (Monitor and Blue Chalk) was evaluated for both the dermal and inhalation exposure pathways by determining bioaccessibility in artificial sweat (pH 5.3 and pH 6.5), airway lining fluid (SUF, pH 7.3), and alveolar macrophage phagolysosomal fluid (PSF, pH 4.5). Significantly more beryllium was released from Monitor pit ore than Blue Chalk pit ore in artificial sweat buffered to pH 5.3 (0.88 +/- 0.01% vs. 0.36 +/- 0.00%) and pH 6.5 (0.09 +/- 0.00% vs. 0.03 +/- 0.01%). Rates of beryllium released from the ores in artificial sweat were faster than previously measured for manufactured forms of beryllium (e.g., beryllium oxide), known to induce sensitization in mice. In SUF, levels of beryllium were below the analytical limit of detection. In PSF, beryllium dissolution was biphasic (initial rapid diffusion followed by latter slower surface reactions). During the latter phase, dissolution half-times were 1,400 to 2,000 days, and rate constants were ~7 x 10(-10) g/(cm(2).day), indicating that bertrandite is persistent in the lung. These data indicate that it is prudent to control skin and inhalation exposures to bertrandite dusts. |
- Page last reviewed:Feb 1, 2024
- Page last updated:Jun 17, 2024
- Content source:
- Powered by CDC PHGKB Infrastructure