Last data update: Dec 09, 2024. (Total: 48320 publications since 2009)
Records 1-7 (of 7 Records) |
Query Trace: Jones JI[original query] |
---|
Development and application of a high throughput one-pot extraction protocol for quantitative LC-MS/MS analysis of phospholipids in serum and lipoprotein fractions in normolipidemic and dyslipidemic subjects
Gardner MS , Kuklenyik Z , Lehtikoski A , Carter KA , McWilliams LG , Kusovschi J , Bierbaum K , Jones JI , Rees J , Reis G , Pirkle JL , Barr JR . J Chromatogr B Analyt Technol Biomed Life Sci 2019 1118-1119 137-147 Progress toward better diagnosis and treatment of lipid metabolism-related diseases requires high throughput approaches for multiplexed quantitative analysis of structurally diverse lipids, including phospholipids (PLs). This work demonstrates a simplified "one-pot" phospholipid extraction protocol, as an alternative to conventional liquid-liquid extraction. Performed in a 96-well format, the extraction was coupled with high throughput UPLC and multiplexed tandem mass spectrometry (MS/MS) detection, allowing non-targeted quantification of phosphatidylcholines (PC), sphingomyelins (SM), lysophosphatidylcholines (LPC), phosphatidylethanolamines (PE), and phosphatidylinositols (PI). Using 50muL aliquots of serum samples from 110 individuals, lipoproteins were fractionated by size, and analyzed for phospholipids and non-polar lipids including free cholesterol (FC), cholesteryl esters (CEs) and triglycerides (TGs). Analysis of serum samples with wide range of Total-TG levels showed significant differences in PL composition. The correlations of molar ratios in lipoprotein size fractions, SM/PL with FC/PL, PE/PL with TG/CE, and PE/PL with PI/PL, demonstrate the applicability of the method for quantitative composition analysis of high, low and very-low density lipoproteins (HDL, LDL and VLDL), and characterization of lipid metabolism related disease states. |
Core lipid, surface lipid and apolipoprotein composition analysis of lipoprotein particles as a function of particle size in one workflow integrating asymmetric flow field-flow fractionation and liquid chromatography-tandem mass spectrometry
Kuklenyik Z , Jones JI , Gardner MS , Schieltz DM , Parks BA , Toth CA , Rees JC , Andrews ML , Carter K , Lehtikoski AK , McWilliams LG , Williamson YM , Bierbaum KP , Pirkle JL , Barr JR . PLoS One 2018 13 (4) e0194797 Lipoproteins are complex molecular assemblies that are key participants in the intricate cascade of extracellular lipid metabolism with important consequences in the formation of atherosclerotic lesions and the development of cardiovascular disease. Multiplexed mass spectrometry (MS) techniques have substantially improved the ability to characterize the composition of lipoproteins. However, these advanced MS techniques are limited by traditional pre-analytical fractionation techniques that compromise the structural integrity of lipoprotein particles during separation from serum or plasma. In this work, we applied a highly effective and gentle hydrodynamic size based fractionation technique, asymmetric flow field-flow fractionation (AF4), and integrated it into a comprehensive tandem mass spectrometry based workflow that was used for the measurement of apolipoproteins (apos A-I, A-II, A-IV, B, C-I, C-II, C-III and E), free cholesterol (FC), cholesterol esters (CE), triglycerides (TG), and phospholipids (PL) (phosphatidylcholine (PC), sphingomyelin (SM), phosphatidylethanolamine (PE), phosphatidylinositol (PI) and lysophosphatidylcholine (LPC)). Hydrodynamic size in each of 40 size fractions separated by AF4 was measured by dynamic light scattering. Measuring all major lipids and apolipoproteins in each size fraction and in the whole serum, using total of 0.1 ml, allowed the volumetric calculation of lipoprotein particle numbers and expression of composition in molar analyte per particle number ratios. Measurements in 110 serum samples showed substantive differences between size fractions of HDL and LDL. Lipoprotein composition within size fractions was expressed in molar ratios of analytes (A-I/A-II, C-II/C-I, C-II/C-III. E/C-III, FC/PL, SM/PL, PE/PL, and PI/PL), showing differences in sample categories with combinations of normal and high levels of Total-C and/or Total-TG. The agreement with previous studies indirectly validates the AF4-LC-MS/MS approach and demonstrates the potential of this workflow for characterization of lipoprotein composition in clinical studies using small volumes of archived frozen samples. |
Simultaneous quantification of free cholesterol, cholesteryl esters, and triglycerides without ester hydrolysis by UHPLC separation and in-source collision induced dissociation coupled MS/MS
Gardner MS , McWilliams LG , Jones JI , Kuklenyik Z , Pirkle JL , Barr JR . J Am Soc Mass Spectrom 2017 28 (11) 2319-2329 We demonstrate the application of in-source nitrogen collision-induced dissociation (CID) that eliminates the need for ester hydrolysis before simultaneous analysis of esterified cholesterol (EC) and triglycerides (TG) along with free cholesterol (FC) from human serum, using normal phase liquid chromatography (LC) coupled to atmospheric pressure chemical ionization (APCI) tandem mass spectrometry (MS/MS). The analysis requires only 50 muL of 1:100 dilute serum with a high-throughput, precipitation/evaporation/extraction protocol in one pot. Known representative mixtures of EC and TG species were used as calibrators with stable isotope labeled analogs as internal standards. The APCI MS source was operated with nitrogen source gas. Reproducible in-source CID was achieved with the use of optimal cone voltage (declustering potential), generating FC, EC, and TG lipid class-specific precursor fragment ions for multiple reaction monitoring (MRM). Using a representative mixture of purified FC, CE, and TG species as calibrators, the method accuracy was assessed with analysis of five inter-laboratory standardization materials, showing -10% bias for Total-C and -3% for Total-TG. Repeated duplicate analysis of a quality control pool showed intra-day and inter-day variation of 5% and 5.8% for FC, 5.2% and 8.5% for Total-C, and 4.1% and 7.7% for Total-TG. The applicability of the method was demonstrated on 32 serum samples and corresponding lipoprotein sub-fractions collected from normolipidemic, hypercholesterolemic, hypertriglyceridemic, and hyperlipidemic donors. The results show that in-source CID coupled with isotope dilution UHPLC-MS/MS is a viable high precision approach for translational research studies where samples are substantially diluted or the amounts of archived samples are limited. |
Optimization of the linear quantification range of an online trypsin digestion coupled liquid chromatography-tandem mass spectrometry (LC-MS/MS) platform
Kuklenyik Z , Jones JI , Toth CA , Gardner MS , Pirkle JL , Barr JR . Instrum Sci Technol 2017 46 (1) 102-114 Tandem mass spectrometry (MS/MS)-based proteomic workflows with a bottom-up approach require enzymatic digestion of proteins to peptide analytes, usually by trypsin. Online coupling of trypsin digestion of proteins, using an immobilized enzyme reactor (IMER), with liquid chromatography (LC) and MS/MS is becoming a frequently used approach. However, finding IMER digestion conditions that allow quantitative analysis of multiple proteins with wide range of endogenous concentration requires optimization of multiple interactive parameters: digestion buffer flow rate, injection volume, sample dilution, and surfactant type/concentration. In this report, we present a design of experiment approach for the optimization of an integrated IMER-LC-MS/MS platform. With bovine serum albumin as a model protein, the digestion efficacy and digestion rate were monitored based on LC-MS/MS peak area count versus protein concentration regression. The optimal parameters were determined through multivariate surface response modeling and consideration of diffusion controlled immobilized enzyme kinetics. The results may provide guidance to other users for the development of quantitative IMER-LC-MS/MS methods for other proteins. |
High throughput quantification of apolipoproteins A-I and B-100 by isotope dilution mass spectrometry targeting fast trypsin releasable peptides without reduction and alkylation
Parks BA , Schieltz DM , Andrews ML , Gardner MS , Rees JC , Toth CA , Jones JI , McWilliams LG , Kuklenyik Z , Pirkle JL , Barr JR . Proteomics Clin Appl 2017 11 PURPOSE: Apolipoprotein A-I (ApoA-I) and Apolipoprotein B-100 (ApoB-100) are amphipathic proteins that are strong predictors of cardiovascular disease risk. The traceable calibration of apolipoprotein assays is a persistent challenge, especially for ApoB-100, which cannot be solubilized in purified form. EXPERIMENTAL DESIGN: Simultaneous quantitation method for ApoA-I and ApoB-100 was developed using tryptic digestion without pre-digestion reduction and alkylation, followed by liquid chromatography separation coupled with isotope dilution mass spectrometry (IDMS) analysis. The accuracy of the method was assured by selecting structurally exposed signature peptides, optimal choice of detergent, protein:enzyme ratio, and incubation time. Peptide calibrators were value assigned by isobaric-tagging-IDMS amino acid analysis. RESULTS: The method reproducibility was validated in technical repeats of three serum samples, giving 2-3% intra-day CVs (N = 5) and <7% inter-day CVs (N = 21). The repeated analysis of inter-laboratory harmonization standards showed -1% difference for ApoA-I and -12% for ApoB-100 relative to the assigned value. The applicability of the method was demonstrated by repeated analysis of 24 patient samples with a wide range of total cholesterol and triglyceride levels. CONCLUSIONS AND CLINICAL RELEVANCE: The method is applicable for simultaneous analysis of ApoA-I and ApoB-100 in patient samples, and for characterization of serum pool calibrators for other analytical platforms. |
On-column trypsin digestion coupled with LC-MS/MS for quantification of apolipoproteins
Toth CA , Kuklenyik Z , Jones JI , Parks BA , Gardner MS , Schieltz DM , Rees JC , Andrews ML , McWilliams LG , Pirkle JL , Barr JR . J Proteomics 2016 150 258-267 Apolipoproteins measured in plasma or serum are potential biomarkers for assessing metabolic irregularities that are associated with the development of cardiovascular disease (CVD). LC-MS/MS allows quantitative measurement of multiple apolipoproteins in the same sample run.However, the accuracy and precision of the LC-MS/MS measurement depends on the reproducibility of the enzymatic protein digestion step. With the application of an immobilized enzyme reactor (IMER), the reproducibility of the trypsin digestion can be controlled with high precision via flow rate, column volume and temperature. In this report, we demonstrate the application of an integrated IMER-LC-MS/MS platform for the simultaneous quantitative analysis of eight apolipoproteins. Using a dilution series of a characterized serum pool as calibrator, the method was validated by repeated analysis of pooled sera and individual serum samples with a wide range of lipid profiles, all showing intra-assay CV<4.4% and inter-assay CV<8%. In addition, the method was compared with traditional homogeneous digestion coupled LC-MS/MS for the quantification of apoA-I and apoB-100. Applied in large scale human population studies, this method can serve the translation of a wider panel of apolipoprotein biomarkers from research to clinical application. SIGNIFICANCE: Currently, the translation of apolipoprotein biomarkers to clinical application is impaired because of the high cost of large cohort studies using traditional single-analyte immunoassays. The application of on-line tryptic digestion coupled with LC-MS/MS analysis is an effective way to address this problem. In this work we demonstrate a high throughput, multiplexed, automated proteomics workflow for the simultaneous analysis of multiple proteins. |
The effects of apolipoprotein B depletion on HDL subspecies composition and function
Davidson WS , Heink A , Sexmith H , Melchior JT , Gordon SM , Kuklenyik Z , Woolett L , Barr JR , Jones JI , Toth CA , Shah AS . J Lipid Res 2016 57 (4) 674-86 High density lipoprotein (HDL) cholesterol efflux function may be a more robust biomarker of coronary artery disease risk than HDL cholesterol (HDL-C). To study HDL function, apoB containing lipoproteins are precipitated from serum. Whether apoB precipitation affects HDL subspecies composition and function has not been thoroughly investigated. We studied the effects of four common apoB precipitation methods (polyethylene glycol (PEG), dextran sulfate/MgCl2, heparin sodium/MnCl2 and LipoSep immunoprecipitant (IP)) on HDL subspecies composition, apolipoproteins and function (cholesterol efflux and reduction of LDL oxidation). PEG dramatically shifted the size distribution of HDL and apolipoproteins (assessed by two independent methods), while leaving substantial amounts of reagent in the sample. PEG also changed the distribution of cholesterol efflux and LDL oxidation across size fractions, but not overall efflux across the HDL range. Dextran sulfate/MgCl2 and heparin sodium/MnCl2 did not change the size distribution of HDL subspecies but altered the quantity of a subset of apolipoproteins. LipoSep IP resulted in a shift in the HDL size distribution, but less so than PEG. Thus, each of the apoB precipitation methods affected HDL composition and/or size distribution. We conclude that careful evaluation is needed when selecting apoB depletion methods for existing and future bioassays of HDL function. |
- Page last reviewed:Feb 1, 2024
- Page last updated:Dec 09, 2024
- Content source:
- Powered by CDC PHGKB Infrastructure