Last data update: Mar 21, 2025. (Total: 48935 publications since 2009)
Records 1-17 (of 17 Records) |
Query Trace: Isenberg SL[original query] |
---|
N-acetyltyrosine as a biomarker of parenteral nutrition administration in first-tier newborn screening assays
Pickens CA , Sah S , Chandrappa R , Isenberg SL , Courtney ER , Lim T , Chace DH , Lee R , Cuthbert C , Petritis K . Int J Neonatal Screen 2024 10 (4) Parenteral nutrition (PN) is a nutrient solution administered intravenously (IV) to premature babies. PN causes elevations of some amino acids in blood samples that are also biomarkers used in newborn screening (NBS). Therefore, PN status must be annotated by clinicians on dried blood spot (DBS) cards to reduce NBS laboratory burdens associated with potential false results; however, NBS laboratories continue to receive DBSs with misannotated PN status. N-acetyltyrosine (NAT), a water-soluble tyrosine analog used to increase tyrosine bioavailability in PN solutions, can be used as a blood-based biomarker of PN administration in NBS assays. Residual DBS specimens and manufactured DBSs were used in analyses. The assay was developed and validated using flow injection analysis tandem mass spectrometry (FIA-MS/MS) for the detection of NAT. NAT was only present in neonate DBSs with annotated PN administration and was multiplexed into first-tier newborn screening assays. NAT was highly correlated with amino acids present in PN solutions, such as arginine, leucine, methionine, phenylalanine, and valine. In our sample cohort, we determined an NAT cutoff could aid the identification of misannotated neonates administered PN. We also report the Amadori rearrangement product valine-hexose (Val-Hex) was quantifiable in neonates administered PN, which we suspect forms in the PN solution and/or IV lines. Here, we present the first known use of NAT as a biomarker of PN administration, which is currently being piloted by two U.S. NBS laboratories. NAT and Val-Hex can aid the identification of misannotated DBSs from neonates administered PN, thus decreasing false positive rates. |
Multiplexing homocysteine into first-tier newborn screening mass spectrometry assays using selective thiol derivatization
Pickens CA , Courtney E , Isenberg SL , Cuthbert C , Petritis K . Clin Chem 2023 69 (5) 470-481 BACKGROUND: Classical homocystinuria (HCU) results from deficient cystathionine β-synthase activity, causing elevated levels of Met and homocysteine (Hcy). Newborn screening (NBS) aims to identify HCU in pre-symptomatic newborns by assessing Met concentrations in first-tier screening. However, unlike Hcy, Met testing leads to a high number of false-positive and -negative results. Therefore, screening for Hcy directly in first-tier screening would be a better biomarker for use in NBS. METHODS: Dried blood spot (DBS) quality control and residual clinical specimens were used in analyses. Several reducing and maleimide reagents were investigated to aid in quantification of total Hcy (tHcy). The assay which was developed and validated was performed by flow injection analysis-tandem mass spectrometry (FIA-MS/MS). RESULTS: Interferents of tHcy measurement were identified, so selective derivatization of Hcy was employed. Using N-ethylmaleimide (NEM) to selectively derivatize Hcy allowed interferent-free quantification of tHcy by FIA-MS/MS in first-tier NBS. The combination of tris(2-carboxyethyl)phosphine (TCEP) and NEM yielded significantly less matrix effects compared to dithiothreitol (DTT) and NEM. Analysis of clinical specimens demonstrated that the method could distinguish between HCU-positive, presumptive normal newborns, and newborns receiving total parenteral nutrition. CONCLUSIONS: Here we present the first known validated method capable of screening tHcy in DBS during FIA-MS/S first-tier NBS. |
Combining first and second-tier newborn screening in a single assay using high-throughput chip-based capillary electrophoresis coupled to high-resolution mass spectrometry
Austin Pickens C , Isenberg SL , Cuthbert C , Petritis K . Clin Chem 2021 67 (12) 1709-1720 BACKGROUND: Most first-tier newborn screening (NBS) biomarkers are evaluated by a 2-min flow injection analysis coupled to tandem mass spectrometry (FIA-MS/MS) assay. The absence of separation prior to MS/MS analysis can lead to false positives and inconclusive results due to interferences by nominal isobars and isomers. Therefore, many presumptive positive specimens require confirmation by a higher specificity second-tier assay employing separations, which require additional time and resources prior to patient follow-up. METHODS: A 3.2-mm punch was taken from dried blood spot (DBS) specimens and extracted using a solution containing isotopically labeled internal standards for quantification. Analyses were carried out in positive mode using a commercially available microfluidic capillary electrophoresis (CE) system coupled to a high-resolution mass spectrometer (HRMS). RESULTS: The CE-HRMS platform quantified 35 first- and second-tier biomarkers from a single injection in <2-min acquisition time, thus, successfully multiplexing first- and second-tier NBS for over 20 disorders in a single DBS punch. The CE-HRMS platform resolved problematic isobars and isomers that affect first-tier FIA-MS/MS assay specificity, while achieving similar quantitative results and assay linearity. CONCLUSIONS: Our CE-HRMS assay is capable of multiplexing first- and second-tier NBS biomarkers into a single assay with an acquisition time of <2 min. Such an assay would reduce the volume of false positives and inconclusive specimens flagged for second-tier screening. |
The effects of gamma irradiation on chemical biomarker recovery from mixed chemical/biological threat exposure specimens
Isenberg SL , Carter MD , Moon JL , Laughlin S , Petway M , Mojica MA , Rood JE , Gursky AK , Sheppard CI , Bagarozzi DA , Pirkle JL , Johnson RC . J Appl Lab Med 2020 5 (2) 273-280 BACKGROUND: Irradiative sterilization of clinical specimens prior to chemical laboratory testing provides a way to not only sterilize pathogens and ensure laboratorian safety but also preserve sample volume and maintain compatibility with quantitative chemical diagnostic protocols. Since the compatibility of clinical biomarkers with gamma irradiation is not well characterized, a subset of diagnostic biomarkers ranging in molecular size, concentration, and clinical matrix was analyzed to determine recovery following gamma irradiation. METHODS: Sample irradiation of previously characterized quality control materials (QCs) at 5 Mrad was carried out at the Gamma Cell Irradiation Facility at the Centers for Disease Control and Prevention (CDC) in Atlanta, GA. Following irradiation, the QCs were analyzed alongside non-irradiated QCs to determine analyte recovery between dosed and control samples. RESULTS: Biomarkers for exposure to abrin, ricin, and organophosphorus nerve agents (OPNAs) were analyzed for their stability following gamma irradiation. The diagnostic biomarkers included adducts to butyrylcholinesterase, abrine, and ricinine, respectively, and were recovered at over 90% of their initial concentration. CONCLUSIONS: The results from this pilot study support the implementation of an irradiative sterilization protocol for possible mixed-exposure samples containing both chemical and biological threat agents (mixed CBTs). Furthermore, irradiative sterilization significantly reduces a laboratorian's risk of infection from exposure to an infectious agent without compromising chemical diagnostic testing integrity, particularly for diagnostic assays in which the chemical analyte has been shown to be fully conserved following a 5 Mrad irradiative dose. |
Designing traceable opioid material kits to improve laboratory testing during the U.S. opioid overdose crisis
Mojica MA , Carter MD , Isenberg SL , Pirkle JL , Hamelin EI , Shaner RL , Seymour C , Sheppard CI , Baldwin GT , Johnson RC . Toxicol Lett 2019 317 53-58 In 2017, the U.S. Department of Health and Human Services and the White House declared a public health emergency to address the opioid crisis (Hargan, 2017). On average, 192 Americans died from drug overdoses each day in 2017; 130 (67%) of those died specifically because of opioids (Scholl et al., 2019). Since 2013, there have been significant increases in overdose deaths involving synthetic opioids - particularly those involving illicitly-manufactured fentanyl. The U.S. Drug Enforcement Administration (DEA) estimates that 75% of all opioid identifications are illicit fentanyls (DEA, 2018b). Laboratories are routinely asked to confirm which fentanyl or other opioids are involved in an overdose or encountered by first responders. It is critical to identify and classify the types of drugs involved in an overdose, how often they are involved, and how that involvement may change over time. Health care providers, public health professionals, and law enforcement officers need to know which opioids are in use to treat, monitor, and investigate fatal and non-fatal overdoses. By knowing which drugs are present, appropriate prevention and response activities can be implemented. Laboratory testing is available for clinically used and widely recognized opioids. However, there has been a rapid expansion in new illicit opioids, particularly fentanyl analogs that may not be addressed by current laboratory capabilities. In order to test for these new opioids, laboratories require reference standards for the large number of possible fentanyls. To address this need, the Centers for Disease Control and Prevention (CDC) developed the Traceable Opioid Material( section sign) Kits product line, which provides over 150 opioid reference standards, including over 100 fentanyl analogs. These kits were designed to dramatically increase laboratory capability to confirm which opioids are on the streets and causing deaths. The kits are free to U.S based laboratories in the public, private, clinical, law enforcement, research, and public health domains. |
Rapid quantification of two chemical nerve agent metabolites in serum
Kammer M , Kussrow A , Carter MD , Isenberg SL , Johnson RC , Batchelor RH , Jackson GW , Bornhop DJ . Biosens Bioelectron 2019 131 119-127 Organophosphorus compounds (OPs) continue to represent a significant chemical threat to humans due to exposures from their use as weapons, their potential storage hazards, and from their continued use agriculturally. Existing methods for detection include ELISA and mass spectrometry. The new approach presented here provides an innovative first step toward a portable OP quantification method that surmounts conventional limitations involving sensitivity, selectivity, complexity, and portability. DNA affinity probes, or aptamers, represent an emerging technology that, when combined with a mix-and-read, free-solution assay (FSA) and a compensated interferometer (CI) can provide a novel alternative to existing OP nerve agent (OPNA) quantification methods. Here it is shown that FSA can be used to rapidly screen prospective aptamers in the biological matrix of interest, allowing the identification of a 'best-in-class' probe. It is also shown that combining aptamers with FSA-CI enables quantification of the OPNA metabolites, Sarin (NATO designation "G-series, B", or GB) and Venomous Agent X (VX) acids, rapidly with high selectivity at detection limits of sub-10pg/mL in 25% serum (by volume in PBS). These results suggest there is potential to directly impact diagnostic specificity and sensitivity of emergency response testing methods by both simplifying sample preparation procedures and making a benchtop reader available for OPNA metabolite quantification. |
Quantification of hypoglycin A and methylenecyclopropylglycine in human plasma by HPLC-MS/MS
Sanford AA , Isenberg SL , Carter MD , Mojica MA , Mathews TP , Laughlin S , Thomas JD , Pirkle JL , Johnson RC . J Chromatogr B Analyt Technol Biomed Life Sci 2018 1095 112-118 Hypoglycin A (HGA) and methylenecyclopropylglycine (MCPG) are naturally-occurring amino acids known to cause hypoglycemia and encephalopathy. Exposure to one or both toxins through the ingestion of common soapberry (Sapindaceae) fruits are documented in illness outbreaks throughout the world. Jamaican Vomiting Sickness (JVS) and seasonal pasture myopathy (SPM, horses) are linked to HGA exposure from unripe ackee fruit and box elder seeds, respectively. Acute toxic encephalopathy is linked to HGA and MCPG exposures from litchi fruit. HGA and MCPG are found in several fruits within the soapberry family and are known to cause severe hypoglycemia, seizures, and death. HGA has been directly quantified in horse blood in SPM cases and in human gastric juice in JVS cases. This work presents a new diagnostic assay capable of simultaneous quantification of HGA and MCPG in human plasma, and it can be used to detect patients with toxicity from soapberry fruits. The assay presented herein is the first quantitative method for MCPG in blood matrices. |
Quantification of ricinine and abrine in human plasma by HPLC-MS-MS: Biomarkers of exposure to ricin and abrin
Isenberg SL , Carter MD , Miller MA , Noras AI , Mojica MA , Carlsen ST , Bulathsinghala CP , Thomas JD , Johnson RC . J Anal Toxicol 2018 42 (9) 630-636 Ricin and abrin are toxic ribosome-inactivating proteins found in plants. Exposure to these toxins can be detected using the biomarkers ricinine and abrine, which are present in the same plant sources as the toxins. The concentration of the biomarkers in urine and blood will be dependent upon the purification of abrin or ricin, the route of exposure, and the length of time between exposure and sample collection. Here, we present the first diagnostic assay for the simultaneous quantification of both ricinine and abrine in blood matrices. Furthermore, this is the first-ever method for the detection of abrine in blood products. Samples were processed by isotope-dilution, solid-phase extraction, protein precipitation and quantification by HPLC-MS-MS. This analytical method detects abrine from 5.00 to 500 ng/mL and ricinine from 0.300 to 300 ng/mL with coefficients of determination of 0.996 +/- 0.003 and 0.998 +/- 0.002 (n = 22), respectively. Quality control material accuracy was determined to have <10% relative error, and precision was within 19% relative standard deviation. The assay's time-to-first result is three hours including sample preparation. Furthermore, the method was applied for the quantification of ricinine in the blood of a patient who had intentionally ingested castor beans to demonstrate the test was fit-for-purpose. This assay was designed to support the diagnosis of ricin and abrin exposures in public health investigations. |
Quantitative HPLC-MS/MS analysis of toxins in soapberry seeds: Methylenecyclopropylglycine and hypoglycin A
Sanford AA , Isenberg SL , Carter MD , Mojica MA , Mathews TP , Harden LA , Takeoka GR , Thomas JD , Pirkle JL , Johnson RC . Food Chem 2018 264 449-454 Methylenecyclcopropylglycine (MCPG) and hypoglycin A (HGA) are naturally occurring amino acids found in various soapberry (Sapindaceae) fruits. These toxins have been linked to illnesses worldwide and were recently implicated in Asian outbreaks of acute hypoglycemic encephalopathy. In a previous joint agricultural and public health investigation, we developed an analytical method capable of evaluating MCPG and HGA concentrations in soapberry fruit arils as well as a clinical method for the urinary metabolites of the toxins. Since the initial soapberry method only analyzed the aril portion of the fruit, we present here the extension of the method to include the fruit seed matrix. This work is the first method to quantitate both MCPG and HGA concentrations in the seeds of soapberry fruit, including those collected during a public health investigation. Further, this is the first quantitation of HGA in litchi seeds as well as both toxins in mamoncillo and longan seeds. |
Supplemental learning in the laboratory: An innovative approach for evaluating knowledge and method transfer
Carter MD , Pierce SS , Dukes AD , Brown RH , Crow BS , Shaner RL , Heidari L , Isenberg SL , Perez JW , Graham LA , Thomas JD , Johnson RC , Gerdon AE . J Chem Educ 2017 94 (8) 1094-1097 The Multi-Rule Quality Control System (MRQCS) is a tool currently employed by the Centers for Disease Control and Prevention (CDC) to evaluate and compare laboratory performance. We have applied the MRQCS to a comparison of instructor-led and computer-led prelaboratory instruction for a supplemental learning experiment. Students in general chemistry and analytical chemistry from both two- and four-year institutions performed two laboratory experiments as part of their normal laboratory curriculum. The first laboratory experiment was a foundational learning experiment in which all of the students were introduced to the Beer-Lambert law and spectrophotometric light absorbance measurements. The foundational learning experiment was instructor-led only, and participant performance was evaluated against a mean characterized value. The second laboratory experiment was a supplemental learning experiment in which students were asked to build upon the methodology they learned in the foundational learning experiment and apply it to a different analyte. The instruction type was varied randomly into two delivery modes, with participants receiving either instructor-led or computer-led prelaboratory instruction. The MRQCS was applied, and it was determined that there was no statistical difference between the quality control passing rates of the participants receiving instructor-led instruction and those receiving computer-led instruction. These findings demonstrate the successful application of the MRQCS to evaluate knowledge and technology transfer. |
High-confidence qualitative identification of organophosphorus nerve agent adducts to human butyrylcholinesterase
Mathews TP , Carter MD , Johnson D , Isenberg SL , Graham LA , Thomas JD , Johnson RC . Anal Chem 2017 89 (3) 1955-1964 In this study, a data-dependent, high-resolution tandem mass spectrometry (ddHRMS/MS) method capable of detecting all organophosphorus nerve agent (OPNA) adducts to human butyrylcholinesterase (BChE) was developed. After an exposure event, immunoprecipitation from blood with a BChE-specific antibody and digestion with pepsin produces a nine amino acid peptide containing the OPNA adduct. Signature product ions of this peptic BChE nonapeptide (FGES*AGAAS) offer a route to broadly screen for OPNA exposure. Taking this approach on an HRMS instrument identifies biomarkers, including unknowns, with high mass accuracy. Using a set of pooled human sera exposed to OPNAs as quality control (QC) materials, the developed method successfully identified precursor ions with <1 ppm and tied them to signature product ions with <5 ppm deviation from their chemical formulas. This high mass accuracy data from precursor and product ions, collected over 23 independent immunoprecipitation preparations, established method operating limits. QC data and experiments with 14 synthetic reference peptides indicated that reliable qualitative identification of biomarkers was possible for analytes >15 ng/mL. The developed method was applied to a convenience set of 96 unexposed serum samples and a blinded set of 80 samples treated with OPNAs. OPNA biomarkers were not observed in convenience set samples and no false positive or negative identifications were observed in blinded samples. All biomarkers in the blinded serum set >15 ng/mL were correctly identified. For the first time, this study reports a ddHRMS/MS method capable of complementing existing quantitative methodologies and suitable for identifying exposure to unknown organophosphorus agents. |
Association of acute toxic encephalopathy with litchi consumption in an outbreak in Muzaffarpur, India, 2014: a case-control study
Shrivastava A , Kumar A , Thomas JD , Laserson KF , Bhushan G , Carter MD , Chhabra M , Mittal V , Khare S , Sejvar JJ , Dwivedi M , Isenberg SL , Johnson R , Pirkle JL , Sharer JD , Hall PL , Yadav R , Velayudhan A , Papanna M , Singh P , Somashekar D , Pradhan A , Goel K , Pandey R , Kumar M , Kumar S , Chakrabarti A , Sivaperumal P , Kumar AR , Schier JG , Chang A , Graham LA , Mathews TP , Johnson D , Valentin L , Caldwell KL , Jarrett JM , Harden LA , Takeoka GR , Tong S , Queen K , Paden C , Whitney A , Haberling DL , Singh R , Singh RS , Earhart KC , Dhariwal AC , Chauhan LS , Venkatesh S , Srikantiah P . Lancet Glob Health 2017 5 (4) e458-e466 BACKGROUND: Outbreaks of unexplained illness frequently remain under-investigated. In India, outbreaks of an acute neurological illness with high mortality among children occur annually in Muzaffarpur, the country's largest litchi cultivation region. In 2014, we aimed to investigate the cause and risk factors for this illness. METHODS: In this hospital-based surveillance and nested age-matched case-control study, we did laboratory investigations to assess potential infectious and non-infectious causes of this acute neurological illness. Cases were children aged 15 years or younger who were admitted to two hospitals in Muzaffarpur with new-onset seizures or altered sensorium. Age-matched controls were residents of Muzaffarpur who were admitted to the same two hospitals for a non-neurologic illness within seven days of the date of admission of the case. Clinical specimens (blood, cerebrospinal fluid, and urine) and environmental specimens (litchis) were tested for evidence of infectious pathogens, pesticides, toxic metals, and other non-infectious causes, including presence of hypoglycin A or methylenecyclopropylglycine (MCPG), naturally-occurring fruit-based toxins that cause hypoglycaemia and metabolic derangement. Matched and unmatched (controlling for age) bivariate analyses were done and risk factors for illness were expressed as matched odds ratios and odds ratios (unmatched analyses). FINDINGS: Between May 26, and July 17, 2014, 390 patients meeting the case definition were admitted to the two referral hospitals in Muzaffarpur, of whom 122 (31%) died. On admission, 204 (62%) of 327 had blood glucose concentration of 70 mg/dL or less. 104 cases were compared with 104 age-matched hospital controls. Litchi consumption (matched odds ratio [mOR] 9.6 [95% CI 3.6 - 24]) and absence of an evening meal (2.2 [1.2-4.3]) in the 24 h preceding illness onset were associated with illness. The absence of an evening meal significantly modified the effect of eating litchis on illness (odds ratio [OR] 7.8 [95% CI 3.3-18.8], without evening meal; OR 3.6 [1.1-11.1] with an evening meal). Tests for infectious agents and pesticides were negative. Metabolites of hypoglycin A, MCPG, or both were detected in 48 [66%] of 73 urine specimens from case-patients and none from 15 controls; 72 (90%) of 80 case-patient specimens had abnormal plasma acylcarnitine profiles, consistent with severe disruption of fatty acid metabolism. In 36 litchi arils tested from Muzaffarpur, hypoglycin A concentrations ranged from 12.4 mug/g to 152.0 mug/g and MCPG ranged from 44.9 mug/g to 220.0 mug/g. INTERPRETATION: Our investigation suggests an outbreak of acute encephalopathy in Muzaffarpur associated with both hypoglycin A and MCPG toxicity. To prevent illness and reduce mortality in the region, we recommended minimising litchi consumption, ensuring receipt of an evening meal and implementing rapid glucose correction for suspected illness. A comprehensive investigative approach in Muzaffarpur led to timely public health recommendations, underscoring the importance of using systematic methods in other unexplained illness outbreaks. FUNDING: US Centers for Disease Control and Prevention. |
A high-throughput UHPLC-MS/MS method for the quantification of five aged butyrylcholinesterase biomarkers from human exposure to organophosphorus nerve agents
Graham LA , Johnson D , Carter MD , Stout EG , Erol HA , Isenberg SL , Mathews TP , Thomas JD , Johnson RC . Biomed Chromatogr 2016 31 (4) Organophosphorus nerve agents (OPNAs) are toxic compounds that are classified as prohibited Schedule 1 chemical weapons. In the body, OPNAs bind to butyrylcholinesterase (BChE) to form nerve agent adducts (OPNA-BChE). OPNA-BChE adducts can provide a reliable, long-term protein biomarker for assessing human exposure. A major challenge facing OPNA-BChE detection is hydrolysis (aging), which can continue to occur after a clinical specimen has been collected. During aging, the o-alkyl phosphoester bond hydrolyzes, and the specific identity of the nerve agent is lost. To better identify OPNA exposure events, a high throughput method for the detection of five aged OPNA-BChE adducts was developed. This is the first diagnostic panel to allow for the simultaneous quantification of any Chemical Weapons Convention Schedule 1 OPNA by measuring the aged adducts methyl phosphonate (MeP-BChE), ethyl phosphonate (EtP-BChE), propyl phosphonate (PrP-BChE), ethyl phosphoryl (ExP-BChE), phosphoryl (P-BChE), and unadducted BChE. The calibration range for all analytes is 2.00 - 250. ng/mL, which is consistent with similar methodologies used to detect unaged OPNA-BChE adducts. Each analytical run is three minutes making the time to first unknown results, including calibration curve and quality controls, less than one hour. Analysis of commercially purchased individual serum samples demonstrated no potential interferences with detection of aged OPNA-BChE adducts, and quantitative measurements of endogenous levels of BChE were similar to those previously reported in other OPNA-BChE adduct assays. |
Quantification of toxins in soapberry (Sapindaceae) arils: hypoglycin A and methylenecyclopropylglycine
Isenberg SL , Carter MD , Hayes SR , Graham LA , Johnson D , Mathews TP , Harden LA , Takeoka GR , Thomas JD , Pirkle JL , Johnson RC . J Agric Food Chem 2016 64 (27) 5607-13 Methylenecyclopropylglycine (MCPG) and hypoglycin A (HGA) are naturally occurring amino acids found in some soapberry fruits. Fatalities have been reported worldwide as a result of HGA ingestion, and exposure to MCPG has been implicated recently in the Asian outbreaks of hypoglycemic encephalopathy. In response to an outbreak linked to soapberry ingestion, the authors developed the first method to simultaneously quantify MCPG and HGA in soapberry fruits from 1 to 10000 ppm of both toxins in dried fruit aril. Further, this is the first report of HGA in litchi, longan, and mamoncillo arils. This method is presented to specifically address the laboratory needs of public-health investigators in the hypoglycemic encephalitis outbreaks linked to soapberry fruit ingestion. |
Quantification of hydrazine in human urine by HPLC-MS-MS
Isenberg SL , Carter MD , Crow BS , Graham LA , Johnson D , Beninato N , Steele K , Thomas JD , Johnson RC . J Anal Toxicol 2016 40 (4) 248-54 Currently used on F-16 fighter jets and some space shuttles, hydrazine could be released at toxic levels to humans as a result of an accidental leakage or spill. Lower-level exposures occur in industrial workers or as a result of the use of some pharmaceuticals. A method was developed for the quantitation of hydrazine in human urine and can be extended by dilution with water to cover at least six orders of magnitude, allowing measurement at all clinically significant levels of potential exposure. Urine samples were processed by isotope dilution, filtered, derivatized and then quantified by HPLC-MS-MS. The analytical response ratio was linearly proportional to the urine concentration of hydrazine from 0.0493 to 12.3 ng/mL, with an average correlation coefficient R of 0.9985. Inter-run accuracy for 21 runs, expressed as percent relative error (% RE), was ≤14%, and the corresponding precision, expressed as percent relative standard deviation (% RSD), was ≤15%. Because this method can provide a quantitative measurement of clinical samples over six orders of magnitude, it can be used to monitor trace amounts of hydrazine exposure as well as industrial and environmental exposure levels. |
Quantification of metabolites for assessing human exposure to soapberry toxins hypoglycin A and methylenecyclopropylglycine
Isenberg SL , Carter MD , Graham LA , Mathews TP , Johnson D , Thomas JD , Pirkle JL , Johnson RC . Chem Res Toxicol 2015 28 (9) 1753-9 Ingestion of soapberry fruit toxins hypoglycin A and methylenecyclopropylglycine has been linked to public health challenges worldwide. In 1976, over 100 years after Jamaican vomiting sickness (JVS) was first reported, the cause of JVS was linked to the ingestion of the toxin hypoglycin A produced by ackee fruit. A structural analogue of hypoglycin A, methylenecyclopropylglycine (MCPG), was implicated as the cause of an acute encephalitis syndrome (AES). Much of the evidence linking hypoglycin A and MCPG to these diseases has been largely circumstantial due to the lack of an analytical method for specific metabolites. This study presents an analytical approach to identify and quantify specific urine metabolites for exposure to hypoglycin A and MCPG. The metabolites are excreted in urine as glycine adducts methylenecyclopropylacetyl-glycine (MCPA-Gly) and methylenecyclopropylformyl-glycine (MCPF-Gly). These metabolites were processed by isotope dilution, separated by reverse-phase liquid chromatography, and monitored by electrospray ionization tandem mass spectrometry. The analytical response ratio was linearly proportional to the concentration of MCPF-Gly and MCPA-Gly in urine from 0.10 to 20 mug/mL with a correlation coefficient of r > 0.99. The assay demonstrated accuracy ≥80% and precision ≤20% RSD across the calibration range. This method has been applied to assess exposure to hypoglycin A and MCPG as part of a larger public health initiative and was used to provide the first reported identification of MCPF-Gly and MCPA-Gly in human urine. |
Quantitation of ortho-cresyl phosphate adducts to butyrylcholinesterase in human serum by immunomagnetic-UHPLC-MS/MS
Johnson D , Carter MD , Crow BS , Isenberg SL , Graham LA , Erol HA , Watson CM , Pantazides BG , van der Schans MJ , Langenberg JP , Noort D , Blake TA , Thomas JD , Johnson RC . J Mass Spectrom 2015 50 (4) 683-92 Tri-ortho-cresyl phosphate (ToCP) is an anti-wear, flame retardant additive used in industrial lubricants, hydraulic fluids and gasoline. The neurotoxic effects of ToCP arise from the liver-activated metabolite 2-(o-cresyl)-4H-1,3,2-benzodioxaphosphoran-2-one (cresyl saligenin phosphate or CBDP), which inhibits esterase enzymes including butyrylcholinesterase (BChE). Following BChE adduction, CBDP undergoes hydrolysis to form the aged adduct ortho-cresyl phosphoserine (oCP-BChE), thus providing a biomarker of CBDP exposure. Previous studies have identified ToCP in aircraft cabin and cockpit air, but assessing human exposure has been hampered by the lack of a laboratory assay to confirm exposure. This work presents the development of an immunomagnetic-UHPLC-MS/MS method for the quantitation of unadducted BChE and the long-term CBDP biomarker, oCP-BChE, in human serum. The method has a reportable range from 2.0 ng/ml to 150 ng/ml, which is consistent with the sensitivity of methods used to detect organophosphorus nerve agent protein adducts. The assay demonstrated high intraday and interday accuracy (≥85%) and precision (RSD ≤ 15%) across the calibration range. The method was developed for future analyses of potential human exposure to CBDP. Analysis of human serum inhibited in vitro with CBDP demonstrated that the oCP-BChE adduct was stable for at least 72 h at 4, 22 and 37 degrees C. Compared to a previously reported assay, this method requires 75% less sample volume, reduces analysis time by a factor of 20 and demonstrates a threefold improvement in sensitivity. |
- Page last reviewed:Feb 1, 2024
- Page last updated:Mar 21, 2025
- Content source:
- Powered by CDC PHGKB Infrastructure