Characterization of a monoclonal antibody specific to California serogroup orthobunyaviruses and development as a chimeric immunoglobulin M-positive control in human diagnostics
Powers JA , Boroughs KL , Mikula S , Goodman CH , Davis EH , Thrasher EM , Hughes HR , Biggerstaff BJ , Calvert AE . Microbiol Spectr 2023 11 (5) e0196623 California serogroup viruses (CSGVs) of medical importance in the United States include La Crosse virus, Jamestown Canyon virus (JCV), California encephalitis virus, and snowshoe hare virus. Current diagnosis of CSGVs relies heavily on serologic techniques for detecting immunoglobulin M (IgM), an indication of a recent CSGV infection. However, human-positive control sera reactive to viruses in the serogroup are scarce because detection of recent infections is rare. Here, we describe the development of new murine monoclonal antibodies (MAbs) reactive to CSGVs and the engineering of a human-murine chimeric antibody by combining the variable regions of the broadly CSGV cross-reactive murine MAb, 3-3B6/2-3B2 and the constant region of the human IgM. MAb 3-3B6/2-3B2 recognizes a tertiary epitope on the Gn/Gc heterodimer, and epitopes important in JCV neutralization were mapped to the Gc glycoprotein. This engineered human IgM constitutively expressed in a HEK-293 stable cell line can replace human-positive control sera in diagnostic serological techniques such as IgM antibody capture enzyme-linked immunosorbent assay (MAC-ELISA). Compared to the parent murine MAbs, the human-chimeric IgM antibody had identical serological activity to CSGVs in ELISA and demonstrated equivalent reactivity compared to human immune sera in the MAC-ELISA.IMPORTANCEOrthobunyaviruses in the California serogroup cause severe neurological disease in children and adults. While these viruses are known to circulate widely in North America, their occurrence is rare. Serological testing for CSGVs is hindered by the limited availability and volumes of human-positive specimens needed as controls in serologic assays. Here, we described the development of a murine monoclonal antibody cross-reactive to CSGVs engineered to contain the variable regions of the murine antibody on the backbone of human IgM. The chimeric IgM produced from the stably expressing HEK293 cell line was evaluated for use as a surrogate human-positive control in a serologic diagnostic test. |
Laboratory evaluation of RealStar Yellow Fever Virus RT-PCR kit 1.0 for potential use in the global yellow fever laboratory network
Basile AJ , Niedrig M , Lambert AJ , Meurant R , Brault AC , Domingo C , Goodman CH , Johnson BW , Mossel EC , Mulders MN , Velez JO , Hughes HR . PLoS Negl Trop Dis 2022 16 (9) e0010770 BACKGROUND: Early detection of human yellow fever (YF) infection in YF-endemic regions is critical to timely outbreak mitigation. African National Laboratories chiefly rely on serological assays that require confirmation at Regional Reference Laboratories, thus delaying results, which themselves are not always definitive often due to antibody cross-reactivity. A positive molecular test result is confirmatory for YF; therefore, a standardized YF molecular assay would facilitate immediate confirmation at National Laboratories. The WHO-coordinated global Eliminate Yellow Fever Epidemics Laboratory Technical Working Group sought to independently evaluate the quality and performance of commercial YF molecular assays relevant to use in countries with endemic YF, in the absence of stringent premarket assessments. This report details a limited laboratory WHO-coordinated evaluation of the altona Diagnostics RealStar Yellow Fever Virus RT-PCR kit 1.0. METHODOLOGY AND PRINCIPAL FINDINGS: Specific objectives were to assess the assay's ability to detect YF virus strains in human serum from YF-endemic regions, determine the potential for interference and cross-reactions, verify the performance claims as stated by the manufacturer, and assess usability. RNA extracted from normal human serum spiked with YF virus showed the assay to be precise with minimal lot-to-lot variation. The 95% limit of detection calculated was approximately 1,245 RNA copies/ml [95% confidence interval 497 to 1,640 copies/ml]. Positive results were obtained with spatially and temporally diverse YF strains. The assay was specific for YF virus, was not subject to endogenous or exogenous interferents, and was clinically sensitive and specific. A review of operational characteristics revealed that a positivity cutoff was not defined in the instructions for use, but otherwise the assay was user-friendly. CONCLUSIONS AND SIGNIFICANCE: The RealStar Yellow Fever Virus RT-PCR kit 1.0 has performance characteristics consistent with the manufacturer's claims and is suitable for use in YF-endemic regions. Its use is expected to decrease YF outbreak detection times and be instrumental in saving lives. |
Technical viability of the YF MAC-HD ELISA kit for use in yellow fever-endemic regions
Goodman CH , Demanou M , Mulders M , Mendez-Rico J , Basile AJ . PLoS Negl Trop Dis 2021 15 (6) e0009417 Yellow fever (YF), an arboviral disease, affects an estimated 200,000 people and causes 30,000 deaths per year and recently has caused major epidemics in Africa and South America. Timely and accurate diagnosis of YF is critical for managing outbreaks and implementing vaccination campaigns. A YF immunoglobulin M (IgM) antibody-capture (MAC) enzyme-linked immunosorbent assay (ELISA) kit, the YF MAC-HD, was successfully introduced starting in 2018 to laboratories in Africa and South America. The YF MAC-HD kit can be performed in 3.5 hours, test up to 24 samples, and includes all reagents necessary to perform the test, except for water used to dilute wash buffer. In 2018 and 2019, a total of 56 laboratory personnel from 39 countries in Africa and South America were trained to use the kit during workshops, followed by take-home YF IgM proficiency testing (PT) exercises. Participants received either a 10- or 20-sample YF PT panel and performed testing using the YF MAC-HD kit. All countries obtained 90% or higher correct results. These results verified the technical viability and transferability of YF MAC-HD kit use for laboratories in YF-endemic countries. |
Development of diagnostic microsphere-based immunoassays for Heartland virus
Basile AJ , Horiuchi K , Goodman CH , Kosoy O , Panella AJ , Velez JO , Pastula DM , Brault AC , Staples JE , Calvert AE . J Clin Virol 2020 134 104693 BACKGROUND: Heartland virus (HRTV), a recently reclassified member of the genus Bandavirus, family Phenuiviridae, was first isolated in 2009 from a Missouri farmer exhibiting leukopenia and thrombocytopenia with suspected ehrlichiosis. Since then, more HRTV cases have been diagnosed, and firstline laboratory diagnostic assays are needed to identify future infections Objectives. We sought to develop rapid and reliable IgM and IgG microsphere immunoassays (MIAs) to test sera of patients suspected of having HRTV infection, and to distinguish between recent and past infections. STUDY DESIGN: Heartland virus antigen was captured by an anti-HRTV monoclonal antibody covalently bound to microspheres. Antibodies in human sera from confirmed HRTV-positive and negative cases were reacted with the microsphere complexes and detected using a BioPlex® 200 instrument. Assay cutoffs were determined by receiver operator characteristic analysis of the normalized test output values, equivocal zones for each assay were defined, and sensitivities, specificities, accuracies, and imprecision values were calculated. RESULTS: Sensitivities, specificities and accuracies of the IgM and IgG MIAs were all >95 %. Both tests were precise within and between assay plates, and cross-reactivity with other arboviruses was not observed. CONCLUSIONS: HRTV IgM and IgG MIAs are accurate and rapid first-line methods to serologically identify recent and past HRTV infections. |
Mycoplasma detection in a historical arbovirus repository: Commercial kit comparison and implications for improved repository management
Russell BJ , Horiuchi K , Velez JO , Goodman CH , Johnson BW . J Virol Methods 2019 276 113769 The Centers for Disease Control and Prevention, Arbovirus Reference Collection (ARC) contains viral isolates from both environmental and human sources that are maintained in the laboratory through passage in suckling mouse brain and/or vertebrate and invertebrate cell culture. There has been increased concern regarding the effect of mycoplasma contamination on virus growth and its impact on research and phenotypic analysis. Therefore, quality control testing of virus preparations has become a routine part of the ARC quality assurance program. We compared the performance of three kits - the PCR Mycoplasma Detection Kit (ABM), the VenorGem Mycoplasma Detection Kit (Sigma), and the MycoAlert Mycoplasma Detection Kit (Lonza) - against a reference mycoplasma detection assay from the American Tissue Culture Collection (ATCC) using 744 virus preparations in the ARC, representing 721 unique viruses comprising twelve families and unclassified viruses. We found the ABM kit had the highest sensitivity and specificity, followed by the Sigma kit and Lonza kit, when compared to the ATCC kit. An increase in false positives was observed for the Lonza kit for preparations recently passaged in suckling mouse. Our data supports previously reported observations; that once introduced a specific species of mycoplasma is maintained within a lab. |
Ability to serologically confirm recent Zika virus infection in areas with varying past incidence of dengue virus infection in the United States and U.S. territories in 2016
Lindsey NP , Staples JE , Powell K , Rabe IB , Fischer M , Powers AM , Kosoy OI , Mossel EC , Munoz-Jordan JL , Beltran M , Hancock WT , Toews KE , Ellis EM , Ellis BR , Panella AJ , Basile AJ , Calvert AE , Laven J , Goodman CH , Gould CV , Martin SW , Thomas JD , Villanueva J , Mataia ML , Sciulli R , Gose R , Whelen AC , Hills SL . J Clin Microbiol 2017 56 (1) Background. Cross-reactivity within flavivirus antibody assays, produced by shared epitopes in the envelope proteins, can complicate serological diagnosis of Zika virus (ZIKAV) infection. We assessed the utility of the plaque reduction neutralization test (PRNT) to confirm recent ZIKAV infections and rule out misleading positive IgM results in areas with varying past dengue virus (DENV) infection incidence. Methods. We reviewed PRNT results of sera collected for diagnosis of ZIKAV infection from January 1 through August 31, 2016 with positive ZIKAV IgM results and ZIKAV and DENV PRNT performed. PRNT result interpretations included ZIKAV, unspecified flavivirus, DENV infection, or negative. For this analysis, ZIKAV IgM was considered false-positive for samples interpreted as DENV infection or negative. Results. In US states, 208 (27%) of 759 IgM positives were confirmed as ZIKAV, compared to 11 (21%) of 52 in the US Virgin Islands (USVI), 15 (15%) of 103 in American Samoa, and 13 (11%) of 123 in Puerto Rico. In American Samoa and Puerto Rico, more than 80% of IgM positives were unspecified flavivirus infections. The false-positivity rate was 27% in US states, 18% in USVI, 2% in American Samoa, and 6% in Puerto Rico. Conclusions. In US states, PRNT provided a virus-specific diagnosis or ruled out infection in the majority of IgM positive samples. Almost a third of ZIKAV IgM positive results did not confirm; therefore, providers and patients must understand that IgM results are preliminary. In territories with historically higher DENV transmission, PRNT usually could not differentiate between ZIKAV and DENV infections. |
Evaluation of three commercially-available chikungunya virus immunoglobulin G immunoassays
De Salazar PM , Valadere AM , Goodman CH , Johnson BW . Rev Panam Salud Publica 2017 41 e62 The emergence of chikungunya virus in the Americas means the affected population is at risk of developing severe, chronic, rheumatologic disease, even months after acute infection. Accurate diagnostic methods for past infections are essential for differential diagnosis and consequence management. This study evaluated three commercially-available chikungunya Immunoglobulin G immunoassays by comparing them to an in-house Enzyme-Linked ImmunoSorbent Assay conducted by the Centers for Disease Control and Prevention (Atlanta, Georgia, United States). Results showed sensitivity and specificity values ranging from 92.8% - 100% and 81.8% - 90.9%, respectively, with a significant number of false-positives ranging from 12.5% - 22%. These findings demonstrate the importance of evaluating commercial kits, especially regarding emerging infectious diseases whose medium and long-term impact on the population is unclear. |
Laboratory Diagnosis of Chikungunya Virus Infections and Commercial Sources for Diagnostic Assays.
Johnson BW , Russell BJ , Goodman CH . J Infect Dis 2016 214 S471-s474 Detection of chikungunya virus (CHIKV) or viral RNA is the primary laboratory test used to diagnose infection in serum collected <6 days after onset of illness. Two real-time reverse transcription-polymerase chain reaction (RT-PCR) kits are available commercially, but validity data are limited. There are 2 commercial sources of inactivated positive-control CHIKV RNA to be used with purchased primers. The Centers for Disease Control and Prevention provides viral RNA-positive controls and primer and probe nucleotide sequences for real-time RT-PCR testing. Detection of CHIKV-specific immunoglobulin M (IgM) antibody becomes a sensitive test for samples collected approximately >5 days of illness. Commercially available CHIKV IgM-detection assays include lateral flow rapid tests, IgM antibody capture enzyme-linked immunosorbent assays (MAC-ELISAs), and indirect immunofluorescence tests. Nine commercial CHIKV IgM detection assays were evaluated at 3 reference laboratories to provide guidance to public health diagnostic laboratories on their performance parameters. Sensitivity of the rapid tests and 3 MAC-ELISAs was <50%, and thus these assays are not recommended. Three of the MAC-ELISA kits and 1 indirect immunofluorescence kit had comparable performance to the reference assays. In summary, commercial assays with performance comparable to reference assays are available for molecular and serological diagnosis of CHIKV infections. |
Measuring Haitian children's exposure to chikungunya, dengue and malaria
Poirier MJ , Moss DM , Feeser KR , Streit TG , Chang GJ , Whitney M , Russell BJ , Johnson BW , Basile AJ , Goodman CH , Barry AK , Lammie PJ . Bull World Health Organ 2016 94 (11) 817-825a OBJECTIVE: To differentiate exposure to the newly introduced chikungunya virus from exposure to endemic dengue virus and other pathogens in Haiti. METHODS: We used a multiplex bead assay to detect immunoglobulin G (IgG) responses to a recombinant chikungunya virus antigen, two dengue virus-like particles and three recombinant Plasmodium falciparum antigens. Most (217) of the blood samples investigated were collected longitudinally, from each of 61 children, between 2011 and 2014 but another 127 were collected from a cross-sectional sample of children in 2014. FINDINGS: Of the samples from the longitudinal cohort, none of the 153 collected between 2011 and 2013 but 78.7% (48/61) of those collected in 2014 were positive for IgG responses to the chikungunya virus antigen. In the cross-sectional sample, such responses were detected in 96 (75.6%) of the children and occurred at similar prevalence across all age groups. In the same sample, responses to malarial antigen were only detected in eight children (6.3%) but the prevalence of IgG responses to dengue virus antigens was 60.6% (77/127) overall and increased steadily with age. Spatial analysis indicated that the prevalence of IgG responses to the chikungunya virus and one of the dengue virus-like particles decreased as the sampling site moved away from the city of Leogane and towards the ocean. CONCLUSION: Serological evidence indicates that there had been a rapid and intense dissemination of chikungunya virus in Haiti. The multiplex bead assay appears to be an appropriate serological platform to monitor the seroprevalence of multiple pathogens simultaneously. |
Evaluation of commercially available chikungunya virus immunoglobulin M detection assays
Johnson BW , Goodman CH , Holloway K , de Salazar PM , Valadere AM , Drebot M . Am J Trop Med Hyg 2016 95 (1) 182-192 Commercial chikungunya virus (CHIKV)-specific IgM detection kits were evaluated at the Centers for Disease Control and Prevention (CDC), the Public Health Agency of Canada National Microbiology Laboratory, and the Caribbean Public Health Agency (CARPHA). The Euroimmun Anti-CHIKV IgM ELISA kit had ≥ 95% concordance with all three reference laboratory results. The limit of detection for low CHIK IgM+ samples, as measured by serial dilution of seven sera up to 1:12,800 ranged from 1:800 to 1:3,200. The Euroimmun IIFT kit evaluated at CDC and CARPHA performed well, but required more retesting of equivocal results. The InBios CHIKjj Detect MAC-ELISA had 100% and 98% concordance with CDC and CARPHA results, respectively, and had equal sensitivity to the CDC MAC-ELISA to 1:12,800 dilution in serially diluted samples. The Abcam Anti-CHIKV IgM ELISA initially had high performance at CDC and CARPHA, but at CDC, performance was inconsistent between lots. After replacement of the biotinylated IgM antibody controls with serum containing CHIKV-specific IgM and additional quality assurance/control measures, the Abcam kit was rereleased and reevaluated at CDC. The reformatted Abcam kit had 97% concordance with CDC results and limit of detection of 1:800 to 1:3,200. Two rapid tests and three other CHIKV MAC-ELISAs evaluated at CDC had low sensitivity, as the CDC CHIKV IgM in-house positive controls were below the level of detection. In conclusion, laboratories have options for CHIKV serological diagnosis using validated commercial kits. |
Differential diagnosis of Japanese encephalitis virus infections with the Inbios JE Detect and DEN Detect MAC-ELISA kits
Johnson BW , Goodman CH , Jee YM , Featherstone DA . Am J Trop Med Hyg 2016 94 (4) 820-828 Japanese encephalitis virus (JEV) is the leading cause of pediatric viral neurological disease in Asia. The JEV-specific IgM antibody-capture enzyme-linked immunosorbent assay (MAC-ELISA) in cerebrospinal fluid (CSF) and serum is the recommended method of laboratory diagnosis, but specificity of JEV MAC-ELISA can be low due to cross-reactivity. To increase the specificity of the commercially available JE Detect MAC-ELISA (JE Detect), a differential testing algorithm was developed in which samples tested by JE Detect with positive results were subsequently tested by the DEN Detect MAC-ELISA (DEN Detect) kit, and results of both tests were used to make the final interpretation. The testing algorithm was evaluated with a reference panel of serum and CSF samples submitted for confirmatory testing. In serum, the false Japanese encephalitis (JE) positive rate was reduced, but sequential testing in CSF resulted in reduced JE specificity, as true JEV+ CSF samples had positive results by both JE Detect and DEN Detect and were classified as JE- (dengue virus [DENV]+). Differential diagnosis of JE by sequential testing with JE Detect and DEN Detect increased specificity for JE in serum, but more data with CSF is needed to make a final determination on the usefulness of this testing algorithm for CSF. |
Production of a Sindbis/Eastern Equine Encephalitis chimeric virus inactivated cell culture antigen
Goodman CH , Russell BJ , Velez JO , Laven JJ , Bagarozzi DA Jr , Moon JL , Bedi K , Johnson BW . J Virol Methods 2015 223 19-24 Eastern Equine Encephalitis virus (EEEV) is a medically important pathogen that can cause severe encephalitis in humans, with mortality rates ranging from 30 to 80%. Unfortunately there are no antivirals or licensed vaccines available for human use, and laboratory diagnosis is essential to differentiate EEEV infection from other pathogens with similar clinical manifestations. The Arboviral Diseases Branch (ADB) reference laboratory at the CDC Division of Vector-Borne Diseases (DVBD) produces reference antigens used in serological assays such as the EEEV immunoglobulin M antibody-capture enzyme-linked immunosorbent assay (MAC-ELISA). However, EEEV is classified as a HHS select agent and requires biosafety level (BSL) three containment, limiting EEEV antigen production in non-select agent and BSL-2 laboratories. A recombinant Sindbis virus (SINV)/EEEV has been constructed for use under BSL-2 conditions and is not regulated as a select agent. Cell culture production of inactivated EEEV antigen from SINV/EEEV for use in the EEEV MAC-ELISA is reported here. Cell culture conditions and inactivation procedures were analyzed for SINV/EEEV using a recently developed antigen production algorithm, with the MAC-ELISA as the performance indicator. |
Ebola virus diagnostics: the US Centers for Disease Control and Prevention laboratory in Sierra Leone, August 2014 to March 2015
Flint M , Goodman CH , Bearden S , Blau DM , Amman BR , Basile AJ , Belser JA , Bergeron E , Bowen MD , Brault AC , Campbell S , Chakrabarti AK , Dodd KA , Erickson BR , Freeman MM , Gibbons A , Guerrero LW , Klena JD , Lash RR , Lo MK , McMullan LK , Momoh G , Massally JL , Goba A , Paddock CD , Priestley RA , Pyle M , Rayfield M , Russell BJ , Salzer JS , Sanchez AJ , Schuh AJ , Sealy TK , Steinau M , Stoddard RA , Taboy C , Turnsek M , Wang D , Zemtsova GE , Zivcec M , Spiropoulou CF , Stroher U , Towner JS , Nichol ST , Bird BH . J Infect Dis 2015 212 Suppl 2 S350-8 In August 2014, the Viral Special Pathogens Branch of the US Centers for Disease Control and Prevention established a field laboratory in Sierra Leone in response to the ongoing Ebola virus outbreak. Through March 2015, this laboratory tested >12 000 specimens from throughout Sierra Leone. We describe the organization and procedures of the laboratory located in Bo, Sierra Leone. |
Development of an algorithm for production of inactivated arbovirus antigens in cell culture
Goodman CH , Russell BJ , Velez JO , Laven JJ , Nicholson WL , Bagarozzi DA Jr , Moon JL , Bedi K , Johnson BW . J Virol Methods 2014 208 66-78 Arboviruses are medically important pathogens that cause human disease ranging from a mild fever to encephalitis. Laboratory diagnosis is essential to differentiate arbovirus infections from other pathogens with similar clinical manifestations. The Arboviral Diseases Branch (ADB) reference laboratory at the CDC Division of Vector-Borne Diseases (DVBD) produces reference antigens used in serological assays such as the virus-specific immunoglobulin M antibody-capture enzyme-linked immunosorbent assay (MAC-ELISA). Antigen production in cell culture has largely replaced the use of suckling mice; however, the methods are not directly transferable. The development of a cell culture antigen production algorithm for nine arboviruses from the three main arbovirus families, Flaviviridae, Togaviridae, and Bunyaviridae, is described here. Virus cell culture growth and harvest conditions were optimized, inactivation methods were evaluated, and concentration procedures were compared for each virus. Antigen performance was evaluated by the MAC-ELISA at each step of the procedure. The antigen production algorithm is a framework for standardization of methodology and quality control; however, a single antigen production protocol was not applicable to all arboviruses and needed to be optimized for each virus. |