Last data update: Mar 21, 2025. (Total: 48935 publications since 2009)
Records 1-16 (of 16 Records) |
Query Trace: Feng HA[original query] |
---|
Hazardous exposures and engineering controls in the landscaping services industry
Alexander BM , Graydon PS , Pena M , Feng HA , Beamer BR . J Occup Environ Hyg 2025 1-14 Landscapers are exposed to noise, carbon monoxide (CO), respirable dust, and respirable crystalline silica (RCS) generated from the tools they use. Although engineering controls are available to reduce these exposures, no previous study has evaluated chronic exposures to landscapers in different work settings and compared exposures from landscaping tools with and without engineering controls. This field study of workers in the landscaping services industry documented the occupational exposures of 80 participants at 11 varied worksites to noise, CO, respirable dust, and RCS using personal breathing zone sampling. Results were analyzed using SAS/STAT 14.1. Analysis of variance was used for normally distributed data; otherwise, nonparametric methods were used. Most workers were overexposed to noise, with 94 of the 119 8-hr time-weighted average (TWA) noise exposures at or above the National Institute for Occupational Safety and Health (NIOSH) recommended exposure limit (REL) of 85 dBA. There were no statistically significant differences among different locations or occupations. No 8-hr TWA exposures to CO above the NIOSH REL were measured. Overexposures to RCS were measured at all locations where hardscaping (installing or maintaining non-living aspects of the landscape) was taking place. This is the first known field study of this type to include hardscapers. The use of engineering controls such as dust capture or wet methods would reduce RCS exposures, but respiratory protection may still be needed. Task-based analysis of noise and CO exposure revealed that the loudest landscaping tools used in this study were hardscaping table saws, gas chainsaws, gas leaf blowers, chipper/shredders, gas string trimmers, and fuel mowers. Workers were exposed to significantly more noise and CO when using fuel-powered versions compared to battery-powered versions of leaf blowers, string trimmers, and chainsaws. |
Evaluating earplug performance over a 2-hour work period with a fit-test system
Gong W , Murphy WJ , Meinke DK , Feng HA , Stephenson MR . Semin Hear 2023 44 (4) 470-484 Workers rely on hearing protection devices to prevent occupational noise-induced hearing loss. This study aimed to evaluate changes in attenuation over time for properly fit devices when worn by workers exposed to hazardous noise. Earplug fit testing was accomplished on 30 workers at a brewery facility with three types of foam and three types of premolded earplugs. The personal attenuation ratings (PARs) were measured before and after a 2-hour work period while exposed to hazardous noise levels. The minimum acceptable initial PAR was 15 dB. Average decreases in PAR ranged from -0.7 to -2.6 dB across all six earplug types. Significant changes in PAR were observed for the Foam-1 (p = 0.009) and Premold-3 (p = 0.004) earplugs. A linear mixed regression model using HPD type and study year as fixed effects and subject as random effect was not significant for either fixed effect (α = 0.05). Ninety-five percent of the final PAR measurements maintained the target attenuation of 15 dB. Properly fitting earplugs can be effective at reducing worker's noise exposures over time. The potential for a decrease in attenuation during the work shift should be considered when training workers and establishing the adequacy of protection from hazardous noise exposures. © 2023 Thieme Medical Publishers, Inc.. All rights reserved. |
Use of a negative pressure containment pod within ambulance-workspace during pandemic response
Pena M , Neu DT , Feng HA , Hammond DR , Mead KR , Banerjee RK . J Med Device 2023 17 (1) 011009 Emergency medical service (EMS) providers have a higher potential exposure to infectious agents than the general public (Nguyen et al., 2020, "Risk of COVID-19 Among Frontline Healthcare Workers and the General Community: A Prospective Cohort Study," Lancet Pub. Health, 5(9), pp. e475-e483; Brown et al., 2021, "Risk for Acquiring Coronavirus Disease Illness Among Emergency Medical Service Personnel Exposed to Aerosol-Generating Procedures," Emer. Infect. Disease J., 27(9), p. 2340). The use of protective equipment may reduce, but does not eliminate their risk of becoming infected as a result of these exposures. Prehospital environments have a high risk of disease transmission exposing EMS providers to bioaerosols and droplets from infectious patients. Field intubation procedures may be performed causing the generation of bioaerosols, thereby increasing the exposure of EMS workers to pathogens. Additionally, ambulances have a reduced volume compared to a hospital treatment space, often without an air filtration system, and no control mechanism to reduce exposure. This study evaluated a containment plus filtration intervention for reducing aerosol concentrations in the patient module of an ambulance. Aerosol concentration measurements were taken in an unoccupied research ambulance at National Institute for Occupational Safety and Health (NIOSH) Cincinnati using a tracer aerosol and optical particle counters (OPCs). The evaluated filtration intervention was a containment pod with a high efficiency particulate air (HEPA)-filtered extraction system that was developed and tested based on its ability to contain, capture, and remove aerosols during the intubation procedure. Three conditions were tested (1) baseline (without intervention), (2) containment pod with HEPA-1, and (3) containment pod with HEPA-2. The containment pod with HEPA-filtered extraction intervention provided containment of 95% of the total generated particle concentration during aerosol generation relative to the baseline condition, followed by rapid air cleaning within the containment pod. This intervention can help reduce aerosol concentrations within ambulance patient modules while performing aerosol-generating procedures. |
Evaluating the effectiveness of earplugs in preventing noise-induced hearing loss in an auto parts factory in China
Gong W , Zhao L , Li L , Morata TC , Qiu W , Feng HA , Zhu B . Int J Environ Res Public Health 2021 18 (13) A survey was administered to 385 noise-exposed workers from an auto parts factory and 1268 non-noise-exposed health department employees in China. Individual 8 h A-weighted equiva-lent sound levels (LAeq,8h), earplug personal attenuation ratings (PARs), and pure-tone audiometric tests were performed. The average LAeq,8h of noise-exposed workers was 87 dB (A) with a mean PAR of 7 dB. The prevalence of high-frequency hearing loss was 65% for noise-exposed workers and 33% for the non-noise-exposed employees. The use of earplugs had no observable effect on the prevalence of high-frequency hearing loss of the study participants (OR 0.964, 95% CI 0.925–1.005, p = 0.085). No significant relationship between the effectiveness offered by earplug use and high-frequency hearing thresholds at 3, 4, and 6 kHz was found (t = −1.54, p = 0.125). The mandatory requirement of earplug use without individualized training on how to wear HPDs correctly had no detectable effect on the prevention of hearing loss at the auto parts factory. The hearing conservation program at the surveyed factory was not effective. Periodic hearing tests, earplug fit testing, expanding the offer of different types of hearing protection, and employee education about the importance of protecting their hearing were recommended to the occupational health and safety program. © 2021 by the authors. Licensee MDPI, Basel, Switzerland. |
Surface dosimetry of ultraviolet germicidal irradiation using a colorimetric technique
Neu DT , Mead KR , McClelland TL , Lindsley WG , Martin SB , Heil G , See M , Feng HA . Ann Work Expo Health 2021 65 (5) 605-611 Ultraviolet germicidal irradiation uses ultraviolet C (UV-C) energy to disinfect surfaces in clinical settings. Verifying that the doses of UV-C energy received by surfaces are adequate for proper disinfection levels can be difficult and expensive. Our study aimed to test commercially available colorimetric labels, sensitive to UV-C energy, and compare their precision with an accepted radiometric technique. The color-changing labels were found to predictably change color in a dose-dependent manner that would allow them to act as a qualitative alternative to radiometry when determining the minimum UV-C energy dosage received at surfaces. If deployed using careful protective techniques to avoid unintentional exposure to sunlight or other light sources, the use of colorimetric labels could provide inexpensive, easy, and accurate verification of effective UV-C dosing in clinical spaces. |
Development of a prototype dry decontamination method for particulate contamination: The DryCon system
Alexander BM , Feng HA , Merk G . Am J Disaster Med 2020 15 (4) 261-273 OBJECTIVE: This article describes the development of a prototype dry decontamination system (DryCon) for use in the event of a contamination incident involving a particulate contaminant. Disrobing and showering is currently recommended almost exclusively in mass decontamination, although it may not be feasible when water is scarce, in cold weather environments, or when there may be compliance issues with the requirement to disrobe, ie, unwillingness to disrobe. During disrobing, dust particles could also re-aerosolize, leading to inhalation of contaminants. DESIGN: The DryCon prototype uses air jets for dry decontamination. The system is portable and can run on building-supplied 220-V power or generator power. Multiple contaminated persons can be treated rapidly, one after the other, using this system. SETTING: We tested DryCon in a controlled environment, using a manikin and three different types of fabric squares to investigate its effectiveness, with a decontamination time of 60 seconds. MAIN OUTCOME: At the higher airflow tested, ie, 90 percent of full blower speed or approximately 540 cfm (15 m3/minute), mean decontamination efficiencies of 56.8 percent, 70.3 percent, and 80.7 percent were measured for firefighter (FF) turnout fabric, cotton denim, and polyester double knit fabric, respectively. RESULTS: Removal of this easily re-aerosolized fraction of the contaminants helps protect contaminated people, as well as healthcare providers they come in contact with, from the potential risk of further inhalation exposures from the re-aerosolization caused by doffing clothing. CONCLUSION: The results demonstrate the promise of the DryCon system for use where water is not available, as a first step prior to wet decontamination, or in an industrial setting for post-work-shift decontamination. Further lab and field research will be necessary to prove the effectiveness of this technique in real-world applications and to determine if respiratory protection or other personal protective equipment (PPE) is needed during use of the DryCon system. |
Safe patient handling and mobility (SPHM) for increasingly bariatric patient populations: Factors related to caregivers' self-reported pain and injury
Galinsky T , Deter L , Krieg E , Feng HA , Battaglia C , Bell R , Haddock KS , Hilton T , Lynch C , Matz M , Moscatel S , Riley FD , Sampsel D , Shaw S . Appl Ergon 2020 91 103300 This study was conducted at 5 Veterans Administration Medical Centers (VAMCs). A cross sectional survey was administered to 134 workers who routinely lift and mobilize patients within their workplaces' safe patient handling and mobility (SPHM) programs, which are mandated in all VAMCs. The survey was used to examine a comprehensive list of SPHM and non-SPHM variables, and their associations with self-reported musculoskeletal injury and pain. Previously unstudied variables distinguished between "bariatric" (≥300 lb or 136 kg) and "non-bariatric" (<300 lb or 136 kg) patient handling. Significant findings from stepwise and logistic regression provide targets for workplace improvements, predicting: lower injury odds with more frequently having sufficient time to use equipment, higher back pain odds with more frequent bariatric handling, lower back pain odds with greater ease in following SPHM policies, and lower odds of upper extremity pain with more bariatric equipment, and with higher safety climate ratings. |
Evaluation of an improved prototype mini-baghouse to control the release of respirable crystalline silica from sand movers
Alexander BM , Esswein EJ , Gressel MG , Kratzer JL , Feng HA , Miller AL , Cauda E , Heil G . J Occup Environ Hyg 2017 15 (1) 0 The OSHA final rule on respirable crystalline silica (RCS) will require hydraulic fracturing companies to implement engineering controls to limit workers' exposure to RCS. RCS is generated by pneumatic transfer of quartz-containing sand during hydraulic fracturing operations. Chronic inhalation of RCS can lead to serious disease, including silicosis and lung cancer. NIOSH research identified at least seven sources where RCS aerosols were generated at hydraulic fracturing sites. NIOSH researchers developed an engineering control to address one of the largest sources of RCS aerosol generation, RCS escaping from thief hatches on the top of sand movers. The control, the NIOSH Mini-Baghouse Retrofit Assembly (NMBRA), mounts on the thief hatches. Unlike most commercially-available engineering controls, the NMBRA has no moving parts and requires no power source. This article details the results of an evaluation of generation 3 of the NMBRA at a sand mine in Arkansas from May 19 - 21, 2015. During the evaluation, 168 area air samples were collected at 12 locations on and around a sand mover with and without the NMBRA installed. Analytical results for respirable dust and RCS indicated the use of the NMBRA effectively reduced concentrations of both respirable dust and RCS downwind of the thief hatches. Reductions of airborne respirable dust were estimated at 99+%; reductions in airborne RCS ranged from 98-99%. Analysis of bulk samples of the dust showed the likely presence of freshly fractured quartz, a particularly hazardous form of RCS. Use of an improved filter fabric and a larger area of filter cloth led to substantial improvements in filtration and pressures during these trials, as compared to the generation 2 NMBRA. Planned future design enhancements, including a weather cover, will increase the performance and durability of the NMBRA. Future trials are planned to evaluate the long-term operability of the technology. |
Performance evaluation of mobile downflow booths for reducing airborne particles in the workplace
Lo LM , Hocker B , Steltz AE , Kremer J , Feng HA . J Occup Environ Hyg 2017 14 (11) 0 Compared to other common control measures, the downflow booth is a costly engineering control used to contain airborne dust or particles. The downflow booth provides unidirectional filtered airflow from the ceiling, entraining released particles away from the workers' breathing zone, and delivers contained airflow to a lower level exhaust for removing particulates by filtering media. In this study, we designed and built a mobile downflow booth that is capable of quick assembly and easy size change to provide greater flexibility and particle control for various manufacturing processes or tasks. An experimental study was conducted to thoroughly evaluate the control performance of downflow booths used for removing airborne particles generated by the transfer of powdered lactose between two containers. Statistical analysis compared particle reduction ratios obtained from various test conditions including booth size (short, regular, or extended), supply air velocity (0.41 and 0.51 m/s or 80 and 100 feet per minute, fpm), powder transfer location (near or far from the booth exhaust), and inclusion or exclusion of curtains at the booth entrance. Our study results show that only short-depth downflow booths failed to protect the worker performing powder transfer far from the booth exhausts. Statistical analysis shows that better control performance can be obtained with supply air velocity of 0.51 m/s (100 fpm) than with 0.41 m/s (80 fpm) and that use of curtains for downflow booths did not improve their control performance. |
Interlaboratory evaluation of cellulosic acid-soluble internal air sampling capsules for multi-element analysis
Andrews RN , Feng HA , Ashley K . J Occup Environ Hyg 2015 13 (1) 1-28 An interlaboratory study was carried out to evaluate the use of acid-soluble cellulosic air sampling capsules for their suitability in the measurement of trace elements in workplace atmospheric samples. These capsules are used as inserts to perform closed-face cassette sample collection for occupational exposure monitoring. The interlaboratory study was performed in accordance with NIOSH guidelines that describe statistical procedures for evaluating measurement accuracy of air monitoring methods. The performance evaluation materials used consisted of cellulose acetate capsules melded to mixed-cellulose ester filters that were dosed with multiple elements from commercial standard aqueous solutions. The cellulosic capsules were spiked with the following 33 elements of interest in workplace air monitoring: Ag, Al, As, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe, In, K, La, Li, Mg, Mn, Mo, Ni, P, Pb, Sb, Se, Sn, Sr, Te, Ti, Tl, V, W, Y, Zn, Zr. The elemental loading levels were certified by an accredited provider of certified reference materials. Triplicates of media blanks and multielement-spiked capsules at three different elemental loadings were sent to each participating laboratory; the elemental loading levels were not revealed to the laboratories. The volunteer participating laboratories were asked to prepare the samples by acid dissolution and to analyze aliquots of extracted samples by inductively coupled plasma atomic emission spectrometry in accordance with NIOSH methods. It was requested that the study participants report their analytical results in units of mug of each target element per internal capsule sample. For the majority of the elements investigated (30 out of 33), the study accuracy estimates obtained satisfied the NIOSH accuracy criterion (A < 25%). This investigation demonstrates the utility of acid-soluble internal sampling capsules for multielement analysis by atomic spectrometry. |
Manganese speciation of laboratory-generated welding fumes
Andrews RN , Keane M , Hanley KW , Feng HA , Ashley K . Anal Methods 2015 7 6403-6410 The objective of this laboratory study was to identify and measure manganese (Mn) fractions in chamber-generated welding fumes (WF) and to evaluate and compare the results from a sequential extraction procedure for Mn fractions with that of an acid digestion procedure for measurement of total, elemental Mn. To prepare Mn-containing particulate matter from representative welding processes, a welding system was operated in short circuit gas metal arc welding (GMAW) mode using both stainless steel (SS) and mild carbon steel (MCS) and also with flux cored arc welding (FCAW) and shielded metal arc welding (SMAW) using MCS. Generated WF samples were collected onto polycarbonate filters before homogenization, weighing and storage in scintillation vials. The extraction procedure consisted of four sequential steps to measure various Mn fractions based upon selective solubility: (1) soluble Mn dissolved in 0.01 M ammonium acetate; (2) Mn(0,ii) dissolved in 25% (v/v) acetic acid; (3) Mn(iii,iv) dissolved in 0.5% (w/v) hydroxylamine hydrochloride in 25% (v/v) acetic acid; and (4) insoluble Mn extracted with concentrated hydrochloric and nitric acids. After sample treatment, the four fractions were analyzed for Mn by inductively coupled plasma-atomic emission spectroscopy (ICP-AES). WF from GMAW and FCAW showed similar distributions of Mn species, with the largest concentrations of Mn detected in the Mn(0,ii) and insoluble Mn fractions. On the other hand, the majority of the Mn content of SMAW fume was detected as Mn(iii,iv). Although the concentration of Mn measured from summation of the four sequential steps was statistically significantly different from that measured from the hot block dissolution method for total Mn, the difference is small enough to be of no practical importance for industrial hygiene air samples, and either method may be used for Mn measurement. The sequential extraction method provides valuable information about the oxidation state of Mn in samples and allows for comparison to results from previous work and from total Mn dissolution methods. |
Gravimetric Analysis of Particulate Matter using Air Samplers Housing Internal Filtration Capsules
O'Connor S , O'Connor PF , Feng HA , Ashley K . Gefahrst Reinhalt Luft 2014 74 (10) 403-410 An evaluation was carried out to investigate the suitability of polyvinyl chloride (PVC) internal capsules, housed within air sampling devices, for gravimetric analysis of airborne particles collected in workplaces. Experiments were carried out using blank PVC capsules and PVC capsules spiked with 0,1 - 4 mg of National Institute of Standards and Technology Standard Reference Material(®) (NIST SRM) 1648 (Urban Particulate Matter) and Arizona Road Dust (Air Cleaner Test Dust). The capsules were housed within plastic closed-face cassette samplers (CFCs). A method detection limit (MDL) of 0,075 mg per sample was estimated. Precision S(r) at 0,5 - 4 mg per sample was 0,031 and the estimated bias was 0,058. Weight stability over 28 days was verified for both blanks and spiked capsules. Independent laboratory testing on blanks and field samples verified long-term weight stability as well as sampling and analysis precision and bias estimates. An overall precision estimate Ŝ(rt) of 0,059 was obtained. An accuracy measure of ±15,5% was found for the gravimetric method using PVC internal capsules. |
The relationships between blood lead levels and serum follicle stimulating hormone and luteinizing hormone in the National Health and Nutrition Examination Survey 1999-2002
Krieg EF Jr , Feng HA . Reprod Toxicol 2011 32 (3) 277-85 The relationships between blood lead levels and serum follicle stimulating hormone and luteinizing hormone were assessed in a nationally representative sample of women, 35-60 years old, from the National Health and Nutrition Examination Survey 1999-2002. The blood lead levels of the women ranged from 0.2 to 17.0mcg/dL. The estimated geometric mean was 1.4mcg/dL, and the estimated arithmetic mean was 1.6mcg/dL. As the blood lead level increased, the concentration of serum follicle stimulating hormone increased in post-menopausal women, women who had both ovaries removed, and pre-menopausal women. The concentration of luteinizing hormone increased as blood lead level increased in post-menopausal women and women who had both ovaries removed. The lowest concentrations of blood lead at which a relationship was detected were 0.9mcg/dL for follicle stimulating hormone and 3.2mcg/dL for luteinizing hormone. Lead may act directly or indirectly at ovarian and non-ovarian sites to increase the concentrations of follicle stimulating hormone and luteinizing hormone. |
Occupational exposures to styrene vapor in a manufacturing plant for fiber-reinforced composite wind turbine blades
Hammond D , Garcia A , Feng HA . Ann Occup Hyg 2011 55 (6) 591-600 OBJECTIVES: A utility-scale wind turbine blade manufacturing plant requested assistance from the National Institute for Occupational Safety and Health (NIOSH) in controlling worker exposures to styrene at a plant that produced 37 and 42 m long fiber-reinforced wind turbine blades. The plant requested NIOSH assistance because previous air sampling conducted by the company indicated concerns about peak styrene concentrations when workers entered the confined space inside of the wind turbine blade. NIOSH researchers conducted two site visits and collected personal breathing zone and area air samples while workers performed the wind turbine blade manufacturing tasks of vacuum-assisted resin transfer molding (VARTM), gelcoating, glue wiping, and installing the safety platform. METHODS: All samples were collected during the course of normal employee work activities and analyzed for styrene using NIOSH Method 1501. All sampling was task based since full-shift sampling from a prior Occupational Safety and Health Administration (OSHA) compliance inspection did not show any exposures to styrene above the OSHA permissible exposure limit. During the initial NIOSH site visit, 67 personal breathing zone and 18 area air samples were collected while workers performed tasks of VARTM, gelcoating, glue wipe, and installation of a safety platform. After the initial site visit, the company made changes to the glue wipe task that eliminated the need for workers to enter the confined space inside of the wind turbine blade. During the follow-up site visit, 12 personal breathing zone and 8 area air samples were collected from workers performing the modified glue wipe task. RESULTS: During the initial site visit, the geometric means of the personal breathing zone styrene air samples were 1.8 p.p.m. (n = 21) for workers performing the VARTM task, 68 p.p.m. (n = 5) for workers installing a safety platform, and 340 p.p.m. (n = 14) for workers performing the glue wipe task, where n is the number of workers sampled for a given mean result. Gelcoating workers included job categories of millers, gelcoat machine operators, and gelcoaters. Geometric mean personal breathing zone styrene air samples were 150 p.p.m. (n = 6) for millers, 87 p.p.m. (n = 2) for the gelcoat machine operators, and 66 p.p.m. (n = 19) for gelcoaters. The geometric mean of the personal breathing zone styrene air samples from the glue wipe task measured during the follow-up site visit was 31 p.p.m. (n = 12). CONCLUSIONS: The closed molding VARTM process was very effective at controlling worker exposures to styrene. Personal breathing zone styrene air samples were reduced by an order of magnitude after changes were made to the glue wipe task. The company used chemical substitution to eliminate styrene exposure during the installation of the safety platform. Recommendations were provided to reduce styrene concentrations during gelcoating. |
Risk factors associated with patient assaults of home healthcare workers
Galinsky T , Feng HA , Streit J , Brightwell W , Pierson K , Parsons K , Proctor C . Rehabil Nurs 2010 35 (5) 206-215 This study used surveys from 677 home healthcare aides and nurses to explore factors associated with assaults by patients. Among respondents, 4.6% reported one or more patient assaults (being hit, kicked, pinched, shoved, or bitten) during the past year Logistic regression analysis examined associations between several potential risk factors and assaults. Three factors were significant, including having one or more patients with dementia (OR = 4.31, 95% CI 1.47-12.67), routinely handling patients (OR = 8.48, 95% CI 1.89-37.94), and perceiving threats of violence by others in and around patients' homes (OR = 4.45, 95% CI 7.75-11.32). Assaults were not significantly associated with worker age, gender, race, job title, hours of work, or use of needles during patient care. Assaulted workers and workers who perceived threats of violence by others were significantly more likely to have shortened home care visits. More detailed research is needed to confirm these results and evaluate methods to reduce assault risk. |
Laboratory evaluation to reduce respirable crystalline silica dust when cutting concrete roofing tiles using a masonry saw
Carlo RV , Sheehy J , Feng HA , Sieber WK . J Occup Environ Hyg 2010 7 (4) 245-51 Respirable crystalline silica dust exposure in residential roofers is a recognized hazard resulting from cutting concrete roofing tiles. Roofers cutting tiles using masonry saws can be exposed to high concentrations of respirable dust. Silica exposures remain a serious threat for nearly two million U.S. construction workers. Although it is well established that respiratory diseases associated with exposure to silica dust are preventable, they continue to occur and cause disability or death. The effectiveness of both a commercially available local exhaust ventilation (LEV) system and a water suppression system in reducing silica dust was evaluated separately. The LEV system exhausted 0.24, 0.13, or 0.12 m(3)/sec of dust laden air, while the water suppression system supplied 0.13, 0.06, 0.03, or 0.02 L/sec of water to the saw blade. Using a randomized block design, implemented under laboratory conditions, the aforementioned conditions were evaluated independently on two types of concrete roofing tiles (s-shape and flat) using the same saw and blade. Each engineering control (LEV or water suppression) was replicated eight times, or four times for each type of tile. Analysis of variance was performed by comparing the mean airborne respirable dust concentrations generated during each run and engineering control treatment. The use of water controls and ventilation controls compared with the "no control" treatment resulted in a statistically significant (p < 0.05) reduction of mean respirable dust concentrations generated per tile cut. The percent reduction for respirable dust concentrations was 99% for the water control and 91% for the LEV. Results suggest that water is an effective method for reducing crystalline silica exposures. However, water damage potential, surface discolorations, cleanup, slip hazards, and other requirements may make the use of water problematic in many situations. Concerns with implementing an LEV system to control silica dust exposures include sufficient capture velocity, additional weight of the saw with the LEV system, electricity connections, and cost of air handling unit. |
- Page last reviewed:Feb 1, 2024
- Page last updated:Mar 21, 2025
- Content source: