Last data update: Dec 02, 2024. (Total: 48272 publications since 2009)
Records 1-2 (of 2 Records) |
Query Trace: Daniels LJ[original query] |
---|
Variability of the QuantiFERON(R)-TB Gold In-Tube test using automated and manual methods
Whitworth WC , Goodwin DJ , Racster L , West KB , Chuke SO , Daniels LJ , Campbell BH , Bohanon J , Jaffar AT , Drane W , Sjoberg PA , Mazurek GH . PLoS One 2014 9 (1) e86721 BACKGROUND: The QuantiFERON(R)-TB Gold In-Tube test (QFT-GIT) detects Mycobacterium tuberculosis (Mtb) infection by measuring release of interferon gamma (IFN-gamma) when T-cells (in heparinized whole blood) are stimulated with specific Mtb antigens. The amount of IFN-gamma is determined by enzyme-linked immunosorbent assay (ELISA). Automation of the ELISA method may reduce variability. To assess the impact of ELISA automation, we compared QFT-GIT results and variability when ELISAs were performed manually and with automation. METHODS: Blood was collected into two sets of QFT-GIT tubes and processed at the same time. For each set, IFN-gamma was measured in automated and manual ELISAs. Variability in interpretations and IFN-gamma measurements was assessed between automated (A1 vs. A2) and manual (M1 vs. M2) ELISAs. Variability in IFN-gamma measurements was also assessed on separate groups stratified by the mean of the four ELISAs. RESULTS: Subjects (N = 146) had two automated and two manual ELISAs completed. Overall, interpretations were discordant for 16 (11%) subjects. Excluding one subject with indeterminate results, 7 (4.8%) subjects had discordant automated interpretations and 10 (6.9%) subjects had discordant manual interpretations (p = 0.17). Quantitative variability was not uniform; within-subject variability was greater with higher IFN-gamma measurements and with manual ELISAs. For subjects with mean TB Responses +/-0.25 IU/mL of the 0.35 IU/mL cutoff, the within-subject standard deviation for two manual tests was 0.27 (CI95 = 0.22-0.37) IU/mL vs. 0.09 (CI95 = 0.07-0.12) IU/mL for two automated tests. CONCLUSION: QFT-GIT ELISA automation may reduce variability near the test cutoff. Methodological differences should be considered when interpreting and using IFN-gamma release assays (IGRAs). |
Within-subject interlaboratory variability of QuantiFERON-TB Gold In-Tube tests
Whitworth WC , Hamilton LR , Goodwin DJ , Barrera C , West KB , Racster L , Daniels LJ , Chuke SO , Campbell BH , Bohanon J , Jaffar AT , Drane W , Maserang D , Mazurek GH . PLoS One 2012 7 (9) e43790 BACKGROUND: The QuantiFERON(R)-TB Gold In-Tube test (QFT-GIT) is a viable alternative to the tuberculin skin test (TST) for detecting Mycobacterium tuberculosis infection. However, within-subject variability may limit test utility. To assess variability, we compared results from the same subjects when QFT-GIT enzyme-linked immunosorbent assays (ELISAs) were performed in different laboratories. METHODS: Subjects were recruited at two sites and blood was tested in three labs. Two labs used the same type of automated ELISA workstation, 8-point calibration curves, and electronic data transfer. The third lab used a different automated ELISA workstation, 4-point calibration curves, and manual data entry. Variability was assessed by interpretation agreement and comparison of interferon-gamma (IFN-gamma) measurements. Data for subjects with discordant interpretations or discrepancies in TB Response >0.05 IU/mL were verified or corrected, and variability was reassessed using a reconciled dataset. RESULTS: Ninety-seven subjects had results from three labs. Eleven (11.3%) had discordant interpretations and 72 (74.2%) had discrepancies >0.05 IU/mL using unreconciled results. After correction of manual data entry errors for 9 subjects, and exclusion of 6 subjects due to methodological errors, 7 (7.7%) subjects were discordant. Of these, 6 (85.7%) had all TB Responses within 0.25 IU/mL of the manufacturer's recommended cutoff. Non-uniform error of measurement was observed, with greater variation in higher IFN-gamma measurements. Within-subject standard deviation for TB Response was as high as 0.16 IU/mL, and limits of agreement ranged from -0.46 to 0.43 IU/mL for subjects with mean TB Response within 0.25 IU/mL of the cutoff. CONCLUSION: Greater interlaboratory variability was associated with manual data entry and higher IFN-gamma measurements. Manual data entry should be avoided. Because variability in measuring TB Response may affect interpretation, especially near the cutoff, consideration should be given to developing a range of values near the cutoff to be interpreted as "borderline," rather than negative or positive. |
- Page last reviewed:Feb 1, 2024
- Page last updated:Dec 02, 2024
- Content source:
- Powered by CDC PHGKB Infrastructure