CaF: A sensitive, low-cost filtration method for detecting polioviruses and other enteroviruses in residual waters
Belgasmi H , Miles SJ , Sayyad L , Wong K , Harrington C , Gerloff N , Coulliette-Salmond AD , Guntapong R , Tacharoenmuang R , Ayutthaya AIN , Apostol LNG , Valencia MLD , Burns CC , Benito GR , Vega E . Front Environ Sci 2022 10 Acute flaccid paralysis (AFP) surveillance has been used to identify polio cases and target vaccination campaigns since the inception of the Global Poliovirus Eradication Initiative (GPEI) in 1988. To date, only Afghanistan and Pakistan have failed to interrupt wild poliovirus transmission. Circulation of vaccine-derived polioviruses (VDPV) continues to be a problem in high-risk areas of the Eastern Mediterranean, African, and Southeast Asian regions. Environmental surveillance (ES) is an important adjunct to AFP surveillance, helping to identify circulating polioviruses in problematic areas. Stools from AFP cases and contacts (>200,000 specimens/year) and ES samples (>642 sites) are referred to 146 laboratories in the Global Polio Laboratory Network (GPLN) for testing. Although most World Health Organization supported laboratories use the two-phase separation method due to its simplicity and effectiveness, alternative simple, widely available, and cost-effective methods are needed. The CAF (Concentration and Filtration Elution) method was developed from existing filtration methods to handle any type of sewage or residual waters. At $1020 US per sample for consumable materials, CAF is cost effective, and all equipment and reagents are readily available from markets and suppliers globally. The report describes the results from a parallel study of CAF method with the standard two-phase separation method. The study was performed with samples collected from five countries (Guatemala, Hati, Thailand, Papua New Guinea, and the Philippines), run in three laboratories(United States, Thailand and in the Philippines) to account for regional and sample-to-sample variability. Samples from each site were divided into two 500ml aliquots and processed by both methods, with no other additional concentration or manipulation. The results of 338 parallel-tested samples show that the CAF method is more sensitive than the two-phase separation method for detection of non-polio enteroviruses (p-value < 0.0001) and performed as well as the two-phase separation method for polioviruses detection with no significant difference (p-value > 0.05). The CAF method is a robust, sensitive, and cost-effective method for isolating enteroviruses from residual waters. Copyright 2022 Belgasmi, Miles, Sayyad, Wong, Harrington, Gerloff, Coulliette-Salmond, Guntapong, Tacharoenmuang, Ayutthaya, Apostol, Valencia, Burns, Benito and Vega. |
Environmental Surveillance for Risk Assessment in the Context of a Phase 2 Clinical Trial of Type 2 Novel Oral Polio Vaccine in Panama.
Rojas-Bonilla M , Coulliette-Salmond A , Belgasmi H , Wong K , Sayyad L , Vega E , Grimoldi F , Oberste MS , Ruttimann R . Viruses 2021 13 (7) ![]() ![]() Environmental surveillance was recommended for risk mitigation in a novel oral polio vaccine-2 (nOPV2) clinical trial (M5-ABMG) to monitor excretion, potential circulation, and loss of attenuation of the two nOPV2 candidates. The nOPV2 candidates were developed to address the risk of poliovirus (PV) type 2 circulating vaccine-derived poliovirus (cVDPV) as part of the global eradication strategy. Between November 2018 and January 2020, an environmental surveillance study for the clinical trial was conducted in parallel to the M5-ABMG clinical trial at five locations in Panama. The collection sites were located upstream from local treatment plant inlets, to capture the excreta from trial participants and their community. Laboratory analyses of 49 environmental samples were conducted using the two-phase separation method. Novel OPV2 strains were not detected in sewage samples collected during the study period. However, six samples were positive for Sabin-like type 3 PV, two samples were positive for Sabin-like type 1 PV, and non-polio entero-viruses NPEVs were detected in 27 samples. One of the nOPV2 candidates has been granted Emergency Use Listing by the World Health Organization and initial use started in March 2021. This environmental surveillance study provided valuable risk mitigation information to support the Emergency Use Listing application. Copyright © 2021 by the authors. Licensee MDPI, Basel, Switzerland. |
Environmental Surveillance for Polioviruses in Hati (2017-2019): The Dynamic Process for the Establishment and Monitoring of Sampling Sites
Alleman MM , Coulliette-Salmond AD , Wilnique P , Belgasmi-Wright H , Sayyad L , Wong K , Gue E , Barrais R , Rey-Benito G , Burns CC , Vega E . Viruses 2021 13 (3) Haïti is at risk for wild poliovirus (WPV) importation and circulation, as well as vaccine-derived poliovirus (VDPV) emergence. Environmental surveillance (ES) for polioviruses was established in Port au Prince and Gonaïves in 2016. During 2017-2019, initial ES sites were re-evaluated, and ES was expanded into Cap Haïtien and Saint Marc. Wastewater samples and data on weather, hour of collection, and sample temperature and pH were collected every 4 weeks during March 2017-December 2019 (272 sampling events) from 21 sites in Cap Haïtien, Gonaïves, Port au Prince, and Saint Marc. Samples were processed for the detection of polio and non-polio enteroviruses using the two-phase and "Concentration and Filter Elution" methodologies. Polioviruses were serotyped and underwent intra-typic characterization. No WPV or VDPVs were isolated. Sabin-like polioviruses (oral vaccine strain) of serotypes 1 and 3 were sporadically detected. Five of six (83%), one of six (17%), five of six (83%), and two of three (67%) sites evaluated in Cap Haïtien, Gonaïves, Port au Prince, and Saint Marc, respectively, had enterovirus isolation from >50% of sampling events; these results and considerations, such as watershed population size and overlap, influence of sea water, and excessive particulates in samples, were factors in site retention or termination. The evaluation of 21 ES sampling sites in four Haïtian cities led to the termination of 11 sites. Every-four-weekly sampling continues at the remaining 10 sites across the four cities as a core Global Polio Eradication Initiative activity. |
Validation of the bag-mediated filtration system for environmental surveillance of poliovirus in Nairobi, Kenya
Fagnant-Sperati CS , Ren Y , Zhou NA , Komen E , Mwangi B , Hassan J , Chepkurui A , Nzunza R , Nyangao J , van Zyl WB , Wolfaardt M , Matsapola PN , Ngwana FB , Jeffries-Miles S , Coulliette-Salmond A , Peñaranda S , Vega E , Shirai JH , Kossik AL , Beck NK , Boyle DS , Burns CC , Taylor MB , Borus P , Scott Meschke J . J Appl Microbiol 2020 130 (3) 971-981 AIMS: This study compared the bag-mediated filtration system (BMFS) and standard WHO two-phase separation methods for poliovirus (PV) environmental surveillance, examined factors impacting PV detection, and monitored Sabin-like (SL) PV type 2 presence with withdrawal of oral polio vaccine type 2 (OPV2) in April 2016. METHODS AND RESULTS: Environmental samples were collected in Nairobi, Kenya (Sept 2015-Feb 2017), concentrated via BMFS and two-phase separation methods, then assayed using the WHO PV isolation algorithm and intratypic differentiation diagnostic screening kit. SL1, SL2, and SL3 were detected at higher rates in BMFS than two-phase samples (p<0.05). In BMFS samples, SL PV detection did not significantly differ with volume filtered, filtration time, or filter shipment time (p>0.05), while SL3 was detected less frequently with higher shipment temperatures (p=0.027). SL2 was detected more frequently before OPV2 withdrawal in BMFS and two-phase samples (p<1x10(-5) ). CONCLUSIONS: PV was detected at higher rates with the BMFS, a method that includes a secondary concentration step, than using the standard WHO two-phase method. SL2 disappearance from the environment was commensurate with OPV2 withdrawal. SIGNIFICANCE AND IMPACT OF THE STUDY: The BMFS offers comparable or improved PV detection under the conditions in this study, relative to the two-phase method. |
Persistence of Bacteriophage Phi 6 on Porous and Nonporous Surfaces and the Potential for Its Use as an Ebola Virus or Coronavirus Surrogate.
Whitworth C , Mu Y , Houston H , Martinez-Smith M , Noble-Wang J , Coulliette-Salmond A , Rose L . Appl Environ Microbiol 2020 86 (17) The infection of healthcare workers during the 2013 -2016 Ebola outbreak raised concerns about fomite transmission. In the wake of the Coronavirus Disease 2019 (COVID-19) pandemic, investigations are ongoing to determine the role of fomites in coronavirus transmission as well. The bacteriophage Phi 6 has a phospholipid envelope and is commonly used in environmental studies as a surrogate for human enveloped viruses. The persistence of Phi 6 was evaluated as a surrogate for EBOV and coronaviruses on porous and nonporous hospital surfaces. Phi 6 was suspended in a body fluid simulant and inoculated onto 1 cm(2) coupons of steel, plastic, and two fabric curtain types. The coupons were placed at two controlled absolute humidity (AH) levels; a low AH of 3.0 g/m(3) and a high AH of 14.4 g/m(3) Phi 6 declined at a slower rate on all materials under low AH conditions with a decay rate of 0.06 log10PFU/d to 0.11 log10PFU/d, as compared to the higher AH conditions with a decay rate of 0.65 log10PFU/h to 1.42 log10PFU/d. There was a significant difference in decay rates between porous and non-porous surfaces at both low AH (P < 0.0001) and high AH (P < 0.0001). Under these laboratory-simulated conditions, Phi 6 was found to be a conservative surrogate for EBOV under low AH conditions, in that it persisted longer than Ebola virus in similar AH conditions. Additionally, some coronaviruses persist longer than phi6 under similar conditions, therefore Phi6 may not be a suitable surrogate for coronaviruses.IMPORTANCE Understanding the persistence of enveloped viruses helps inform infection control practices and procedures in healthcare facilities and community settings. These data convey to public health investigators that enveloped viruses can persist and remain infective on surfaces, thus demonstrating a potential risk for transmission. Under these laboratory-simulated western indoor hospital conditions, Phi 6 was used to assess suitability as a surrogate for environmental persistence research related to enveloped viruses, including EBOV and coronaviruses. |
Haiti poliovirus environmental surveillance
Coulliette-Salmond AD , Alleman MM , Wilnique P , Rey-Benito G , Wright HB , Hecker JW , Miles S , Penaranda S , Lafontant D , Corvil S , Francois J , Rossignol E , Stanislas M , Gue E , Faye PC , Castro CJ , Schmidt A , Ng TFF , Burns CC , Vega E . Am J Trop Med Hyg 2019 101 (6) 1240-1248 Poliovirus (PV) environmental surveillance was established in Haiti in three sites each in Port-au-Prince and Gonaives, where sewage and fecal-influenced environmental open water channel samples were collected monthly from March 2016 to February 2017. The primary objective was to monitor for the emergence of vaccine-derived polioviruses (VDPVs) and the importation and transmission of wild polioviruses (WPVs). A secondary objective was to compare two environmental sample processing methods, the gold standard two-phase separation method and a filter method (bag-mediated filtration system [BMFS]). In addition, non-polio enteroviruses (NPEVs) were characterized by next-generation sequencing using Illumina MiSeq to provide insight on surrogates for PVs. No WPVs or VDPVs were detected at any site with either concentration method. Sabin (vaccine) strain PV type 2 and Sabin strain PV type 1 were found in Port-au-Prince, in March and April samples, respectively. Non-polio enteroviruses were isolated in 75-100% and 0-58% of samples, by either processing method during the reporting period in Port-au-Prince and Gonaives, respectively. Further analysis of 24 paired Port-au-Prince samples confirmed the detection of a human NPEV, and echovirus types E-3, E-6, E-7, E-11, E-19, E-20, and E-29. The comparison of the BMFS filtration method to the two-phase separation method found no significant difference in sensitivity between the two methods (mid-P-value = 0.55). The experience of one calendar year of sampling has informed the appropriateness of the initially chosen sampling sites, importance of an adequate PV surrogate, and robustness of two processing methods. |
Feasibility of the bag-mediated filtration system for environmental surveillance of poliovirus in Kenya
Zhou NA , Fagnant-Sperati CS , Komen E , Mwangi B , Mukubi J , Nyangao J , Hassan J , Chepkurui A , Maina C , van Zyl WB , Matsapola PN , Wolfaardt M , Ngwana FB , Jeffries-Miles S , Coulliette-Salmond A , Penaranda S , Shirai JH , Kossik AL , Beck NK , Wilmouth R , Boyle DS , Burns CC , Taylor MB , Borus P , Meschke JS . Food Environ Virol 2019 12 (1) 35-47 The bag-mediated filtration system (BMFS) was developed to facilitate poliovirus (PV) environmental surveillance, a supplement to acute flaccid paralysis surveillance in PV eradication efforts. From April to September 2015, environmental samples were collected from four sites in Nairobi, Kenya, and processed using two collection/concentration methodologies: BMFS (> 3 L filtered) and grab sample (1 L collected; 0.5 L concentrated) with two-phase separation. BMFS and two-phase samples were analyzed for PV by the standard World Health Organization poliovirus isolation algorithm followed by intratypic differentiation. BMFS samples were also analyzed by a cell culture independent real-time reverse transcription polymerase chain reaction (rRT-PCR) and an alternative cell culture method (integrated cell culture-rRT-PCR with PLC/PRF/5, L20B, and BGM cell lines). Sabin polioviruses were detected in a majority of samples using BMFS (37/42) and two-phase separation (32/42). There was statistically more frequent detection of Sabin-like PV type 3 in samples concentrated with BMFS (22/42) than by two-phase separation (14/42, p = 0.035), possibly due to greater effective volume assayed (870 mL vs. 150 mL). Despite this effective volume assayed, there was no statistical difference in Sabin-like PV type 1 and Sabin-like PV type 2 detection between these methods (9/42 vs. 8/42, p = 0.80 and 27/42 vs. 32/42, p = 0.18, respectively). This study demonstrated that BMFS can be used for PV environmental surveillance and established a feasible study design for future research. |
Antibacterial and antiviral effectiveness of two household water treatment devices that use monobrominated hydantoinylated polystyrene
Enger KS , Leak ES , Aw TG , Coulliette AD , Rose JB . J Water Health 2016 14 (6) 950-960 Many different household water treatment (HWT) methods have been researched and promoted to mitigate the serious burden of diarrheal disease in developing countries. However, HWT methods using bromine have not been extensively evaluated. Two gravity-fed HWT devices (AquaSure and Waterbird) were used to test the antimicrobial effectiveness of HaloPure(R) Br beads (monobrominated hydantoinylated polystyrene) that deliver bromine. As water flows over the beads, reactive bromine species are eluted, which inactivate microorganisms. To assess log10 reduction values (LRVs) for Vibrio cholerae, Salmonella enterica Typhimurium, bacteriophage MS2, human adenovirus 2 (HAdV2), and murine norovirus (MN), these organisms were added to potable water and sewage-contaminated water. These organisms were quantified before and after water treatment by the HWT devices. On average, 6 LRVs against Vibrio were attained, as well as 5 LRVs against Salmonella, 4 LRVs against MS2, 5 LRVs against HAdV2, and 3 LRVs against MN. Disinfection was similar regardless of whether sewage was present. Polymer beads delivering bromine to drinking water are a potentially effective and useful component of HWT methods in developing countries. |
Persistence of influenza A (H1N1) virus on stainless steel surfaces
Perry KA , Coulliette AD , Rose LJ , Shams AM , Edwards JR , Noble-Wang JA . Appl Environ Microbiol 2016 82 (11) 3239-3245 As annual influenza epidemics continue to cause significant morbidity and economic burden, an understanding of viral persistence and transmission is critical for public health officials and healthcare workers to better protect patients and their family members from infection. The infectivity and persistence of two influenza A (H1N1) strains (A/New Caledonia/20/1999 and A/Brisbane/59/2007) were evaluated on stainless steel (SS) surfaces using three different surfaces matrices (2% fetal bovine serum, 5 mg/mL mucin, and viral medium) at varying absolute humidity conditions (4.1 x 105 mPa, 6.5 x 105 mPa, 7.1 x 105 mPa, 11.4 x 105 mPa, 11.2 x 105 mPa, and 17.9 x 105 mPa) for up to seven days. Influenza virus was deposited onto SS coupons (7.07 cm2) and recovered by agitation and sonicating in viral medium. Viral persistence was quantified using a tissue culture based enzyme-linked immunosorbent assay (ELISA) to determine the median tissue culture infective dose (TCID50) of infectious virus per coupon. Overall, both strains of influenza A virus remained infectious on SS coupons with an approximate 2 log10 loss over seven days. Factors that influenced viral persistence included absolute humidity, strain/absolute humidity interaction, and time (P ≤ 0.01). Further studies into hand transfer of influenza A virus from fomites and the impact of inanimate surface contamination in transmission should be investigated as this study demonstrates prolonged persistence on non-porous surfaces. IMPORTANCE: The study tested the ability of two influenza A H1N1 strains to persist and remain infectious on stainless steel surfaces in varying environmental conditions. It is demonstrated that influenza A H1N1 virus can persist and remain infectious on stainless steel surfaces for 7 days. This raises the question of what role contaminated surfaces play in the transmission of influenza A virus and that additional studies should be conducted to assess this. |
Draft Genome Sequence of Mycobacterium wolinskyi, a Rapid-Growing Species of Nontuberculous Mycobacteria.
de Man TJ , Perry KA , Lawsin A , Coulliette AD , Jensen B , Toney NC , Limbago BM , Noble-Wang J . Genome Announc 2016 4 (2) ![]() Mycobacterium wolinskyi is a nonpigmented, rapidly growing nontuberculous mycobacterium species that is associated with bacteremia, peritonitis, infections associated with implants/prostheses, and skin and soft tissue infections often following surgical procedures in humans. Here, we report the first functionally annotated draft genome sequence of M. wolinskyi CDC_01. |
Epidemiologic Investigation of a Cluster of Neuroinvasive Bacillus cereus Infections in 5 Patients With Acute Myelogenous Leukemia.
Rhee C , Klompas M , Tamburini FB , Fremin BJ , Chea N , Epstein L , Halpin AL , Guh A , Gallen R , Coulliette A , Gee J , Hsieh C , Desjardins CA , Pedamullu CS , DeAngelo DJ , Manzo VE , Folkerth RD , Milner DA Jr , Pecora N , Osborne M , Chalifoux-Judge D , Bhatt AS , Yokoe DS . Open Forum Infect Dis 2015 2 (3) ofv096 ![]() ![]() BACKGROUND: Five neuroinvasive Bacillus cereus infections (4 fatal) occurred in hospitalized patients with acute myelogenous leukemia (AML) during a 9-month period, prompting an investigation by infection control and public health officials. METHODS: Medical records of case-patients were reviewed and a matched case-control study was performed. Infection control practices were observed. Multiple environmental, food, and medication samples common to AML patients were cultured. Multilocus sequence typing was performed for case and environmental B cereus isolates. RESULTS: All 5 case-patients received chemotherapy and had early-onset neutropenic fevers that resolved with empiric antibiotics. Fever recurred at a median of 17 days (range, 9-20) with headaches and abrupt neurological deterioration. Case-patients had B cereus identified in central nervous system (CNS) samples by (1) polymerase chain reaction or culture or (2) bacilli seen on CNS pathology stains with high-grade B cereus bacteremia. Two case-patients also had colonic ulcers with abundant bacilli on autopsy. No infection control breaches were observed. On case-control analysis, bananas were the only significant exposure shared by all 5 case-patients (odds ratio, 9.3; P = .04). Five environmental or food isolates tested positive for B cereus, including a homogenized banana peel isolate and the shelf of a kitchen cart where bananas were stored. Multilocus sequence typing confirmed that all case and environmental strains were genetically distinct. Multilocus sequence typing-based phylogenetic analysis revealed that the organisms clustered in 2 separate clades. CONCLUSIONS: The investigation of this neuroinvasive B cereus cluster did not identify a single point source but was suggestive of a possible dietary exposure. Our experience underscores the potential virulence of B cereus in immunocompromised hosts. |
MS2 Coliphage as a Surrogate for 2009 Pandemic Influenza A (H1N1) Virus (pH1N1) in Surface Survival Studies on N95 Filtering Facepiece Respirators
Coulliette AD , Perry KA , Fisher EM , Edwards JR , Shaffer RE , Noble-Wang J . J Int Soc Respir Prot 2014 21 (1) 14-22 Research on influenza viruses regarding transmission and survival has surged in the recent years due to infectious emerging strains and outbreaks such as the 2009 Influenza A (H1N1) pandemic. MS2 coliphage has been applied as a surrogate for pathogenic respiratory viruses, such as influenza, as it's safe for personnel to handle and requires less time and labor to measure virus infectivity. However, direct comparisons to determine the effectiveness of coliphage as a surrogate for influenza virus regarding droplet persistence on personal protective equipment such as N95 filtering facepiece respirators (FFRs) are lacking. Persistence of viral droplets deposited on FFRs in healthcare settings is important to discern due to the potential risk of infection via indirect fomite transmission. The objective of this study was to determine if MS2 coliphage could be applied as a surrogate for influenza A viruses for studying persistence when applied to the FFRs as a droplet. The persistence of MS2 coliphage and 2009 Pandemic Influenza A (H1N1) Virus on FFR coupons in different matrices (viral media, 2% fetal bovine serum, and 5 mg ml(-1) mucin) were compared over time (4, 12, 24, 48, 72, and 144 hours) in typical absolute humidity conditions (4.1 × 10(5) mPa [18°C/20% relative humidity (RH)]). Data revealed significant differences in viral infectivity over the 6-day period (H1N1- P <0.0001; MS2 - P <0.005), although a significant correlation of viral log(10) reduction in 2% FBS (P <0.01) was illustrated. Overall, MS2 coliphage was not determined to be a sufficient surrogate for influenza A virus with respect to droplet persistence when applied to the N95 FFR as a droplet. |
Hemodialysis and water quality
Coulliette AD , Arduino MJ . Semin Dial 2013 26 (4) 427-38 Over 383,900 individuals in the U.S. undergo maintenance hemodialysis that exposes them to water, primarily in the form of dialysate. The quality of water and associated dialysis solutions have been implicated in adverse patient outcomes and is therefore critical. The Association for the Advancement of Medical Instrumentation has published both standards and recommended practices that address both water and the dialyzing solutions. Some of these recommendations have been adopted into Federal Regulations by the Centers for Medicare and Medicaid Services as part of the Conditions for Coverage, which includes limits on specific contaminants within water used for dialysis, dialysate, and substitution fluids. Chemical, bacterial, and endotoxin contaminants are health threats to dialysis patients, as shown by the continued episodic nature of outbreaks since the 1960s causing at least 592 cases and 16 deaths in the U.S. The importance of the dialysis water distribution system, current standards and recommendations, acceptable monitoring methods, a review of chemical, bacterial, and endotoxin outbreaks, and infection control programs are discussed. |
Persistence of the 2009 pandemic influenza A (H1N1) virus on N95 respirators
Coulliette AD , Perry KA , Edwards J , Noble-Wang J . Appl Environ Microbiol 2013 79 (7) 2148-55 In the U.S., the 2009 pandemic influenza A (H1N1) virus (pH1N1) infected almost 20% of the population and caused >200,000 hospitalizations and >10,000 deaths during April 2009 to April 2010. On April 24, 2009, CDC posted interim guidance on infection control measures in healthcare settings specifically for pH1N1, which recommended filtering face respirators (FFRs) when in close contact with a suspected/confirmed infected individual and particularly when performing aerosol procedures. The persistence and infectivity of pH1N1 was evaluated on FFRs, specifically N95 respirators, under varying conditions of absolute humidity (AH; 4.1 millibar (mb), 6.5 mb, and 14.6 mb), sample matrices (2% fetal bovine serum (FBS), 5 mg/ml mucin, and viral media), and time (4, 12, 24, 48, 72, and 144 hours). pH1N1 was distributed onto N95 coupons (3.8 to 4.2 cm(2)), extracted by a vortex/centrifugation/filtration process, and the ability of remaining virus to replicate was quantified by ELISA to determine the log(10) concentration of infectious virus per coupon. Overall, pH1N1 remained infectious for 6 days with approximately 1 log(10) loss of viral concentrations over this time period. Time and AH both affected viral survival. We found significantly higher (p ≤0.01) reductions in virus concentrations at time-points beyond 24 to 72 hours (-0.52 log(10) reduction) and 144 hours (-0.74) at AHs of 6.5 mb (-0.53) and 14.6 mb (-0.47). This research supports the discarding of respirators after close contact with a person with suspected or confirmed influenza infection due to the virus's demonstrated ability to persist and remain infectious. |
Risk reduction assessment of waterborne Salmonella and Vibrio by a chlorine contact disinfectant point-of-use device.
Coulliette AD , Enger KS , Weir MH , Rose JB . Int J Hyg Environ Health 2012 216 (3) 355-61 ![]() ![]() Unsafe drinking water continues to burden developing countries despite improvements in clean water delivery and sanitation, in response to Millennium Development Goal 7. Salmonella serotype Typhi and Vibrio cholerae bacteria can contaminate drinking water, causing waterborne typhoid fever and cholera, respectively. Household water treatment (HWT) systems are widely promoted to consumers in developing countries but it is difficult to establish their benefits to the population for specific disease reduction. This research uses a laboratory assessment of halogenated chlorine beads treating contaminated water to inform a quantitative microbial risk assessment (QMRA) of S. Typhi and V. cholerae disease in a developing country community of 1000 people. Laboratory challenges using seeded well water resulted in log(10) reductions of 5.44 (+/-0.98 standard error (SE)) and 6.07 (+/-0.09 SE) for Salmonella serotype Typhimurium and V. cholerae, respectively. In well water with 10% sewage and seeded bacteria, the log(10) reductions were 6.06 (+/-0.62 SE) and 7.78 (+/-0.11 SE) for S. Typhimurium and V. cholerae, respectively. When one infected individual was contributing to the water contamination through fecal material leaking into the water source, the risk of disease associated with drinking untreated water was high according to a Monte Carlo analysis: a median of 0.20 (interquartile range [IQR] 0.017-0.54) for typhoid fever and a median of 0.11 (IQR 0.039-0.20) for cholera. If water was treated, risk greatly decreased, to a median of 4.1x10(-7) (IQR 1.6x10(-8) to 1.1x10(-5)) for typhoid fever and a median of 3.5x10(-9) (IQR 8.0x10(-10) to 1.3x10(-8)) for cholera. Insights on risk management policies and strategies for public health workers were gained using a simple QMRA scenario informed by laboratory assessment of HWT. |