Last data update: Aug 15, 2025. (Total: 49733 publications since 2009)
| Records 1-3 (of 3 Records) |
| Query Trace: Brochu E[original query] |
|---|
| Development of ferret immune repertoire reference resources and single-cell-based high-throughput profiling assays
Walsh ES , Yang K , Tollison TS , Seenu S , Adams N , Zeitoun G , Sideri I , Folch G , Brochu HN , Chou H , Kossida S , York IA , Peng X . J Virol 2025 e0018125
Domestic ferrets (Mustela putorius furo) are important for modeling human respiratory diseases. However, ferret B and T cell receptors have not been completely identified or annotated, limiting immune repertoire studies. Here, we performed long-read transcriptome sequencing of ferret splenocyte and lymph node samples to obtain over 120,000 high-quality full-length immunoglobin (Ig) and T cell receptor (TCR) transcripts. We constructed a complete reference set of the constant regions of ferret Ig and TCR isotypes and chain types. We also systematically annotated germline Ig and TCR variable (V), diversity (D), joining (J), and constant (C) genes on a recent ferret reference genome assembly. We designed new ferret-specific immune repertoire profiling assays by targeting positions in constant regions without allelic diversity across 11 ferret genome assemblies and experimentally validated them using a commercially compatible single-cell-based platform. These improved resources and assays will enable future studies to fully capture ferret immune repertoire diversity.IMPORTANCEDomestic ferrets (Mustela putorius furo) are an increasingly common model organism to study human respiratory diseases such as influenza infections. However, researchers lack ferret-specific reagents and resources to study the immune system and immune response in ferrets. In this study, we developed comprehensive ferret immune repertoire reference resources and assays, which will enable more accurate analyses of the ferret immune system in the future. |
| Fit assessment of N95 filtering-facepiece respirators in the U.S. Centers for Disease Control and Prevention Strategic National Stockpile
Bergman M , Zhuang Z , Brochu E , Palmiero A . J Int Soc Respir Prot 2015 32 (2) 50-64 National Institute for Occupational Safety and Health (NIOSH)-approved N95 filtering-facepiece respirators (FFR) are currently stockpiled by the U.S. Centers for Disease Control and Prevention (CDC) for emergency deployment to healthcare facilities in the event of a widespread emergency such as an influenza pandemic. This study assessed the fit of N95 FFRs purchased for the CDC Strategic National Stockpile. The study addresses the question of whether the fit achieved by specific respirator sizes relates to facial size categories as defined by two NIOSH fit test panels. Fit test data were analyzed from 229 test subjects who performed a nine-donning fit test on seven N95 FFR models using a quantitative fit test protocol. An initial respirator model selection process was used to determine if the subject could achieve an adequate fit on a particular model; subjects then tested the adequately fitting model for the nine-donning fit test. Only data for models which provided an adequate initial fit (through the model selection process) for a subject were analyzed for this study. For the nine-donning fit test, six of the seven respirator models accommodated the fit of subjects (as indicated by geometric mean fit factor > 100) for not only the intended NIOSH bivariate and PCA panel sizes corresponding to the respirator size, but also for other panel sizes which were tested for each model. The model which showed poor performance may not be accurately represented because only two subjects passed the initial selection criteria to use this model. Findings are supportive of the current selection of facial dimensions for the new NIOSH panels. The various FFR models selected for the CDC Strategic National Stockpile provide a range of sizing options to fit a variety of facial sizes. |
| Temporal changes in filtering-facepiece respirator fit
Zhuang Z , Bergman M , Brochu E , Palmiero A , Niezgoda G , He X , Roberge R , Shaffer R . J Occup Environ Hyg 2015 13 (4) 1-30 A three-year study examined changes in N95 filtering-facepiece respirator (FFR) fit at six-month intervals and the relationship between fit and changes in weight for 229 subjects. During each visit, subjects performed a total of nine fit tests using three samples of the same FFR model. Inward leakage and filter penetration were measured for each donned respirator to determine face seal leakage (FSL). A total of 195 subjects completed the second visit and 134 subjects completed all seven visits. Acceptable fit was defined as 90th percentile FSL ≤ 5% and at least one fit factor ≥ 100. An unacceptable fit was observed for 14, 10, 7, 12, 15, and 16% of subjects on Visits 2 through 7, respectively. The predicted risk of an unacceptable fit increased with increasing length of time between fit tests, from 10% at Year 1 to 20% at Year 2 and to 25% at Year 3. Twenty-four percent of subjects who lost ≥ 20 lb had an unacceptable fit; these percentages ranged from 7 to 17% for subjects with lower weight losses or any degree of weight gain. Results support the current OSHA requirement for annual fit testing and suggest that respirator users who lose more than 20 lb should be re-tested for respirator fit. |
- Page last reviewed:Feb 1, 2024
- Page last updated:Aug 15, 2025
- Content source:
- Powered by CDC PHGKB Infrastructure




