Last data update: Apr 29, 2024. (Total: 46658 publications since 2009)
Records 1-2 (of 2 Records) |
Query Trace: Ahamed RA [original query] |
---|
Short- and long-term stability of aromatic amines in human urine
Mazumder S , Ahamed RA , Seyler TH , Wang L . Int J Environ Res Public Health 2023 20 (5) Several aromatic amines (AAs) are established by the International Agency for Research on Cancer as carcinogenic (group 1) or probable/possible carcinogens to humans (group 2A/2B). AAs can be found in mainstream and sidestream smoke from combustible tobacco products, as well as in certain environmental pollution and occupational exposure from several chemical industry sectors. Exposure to AAs can be estimated by measuring their concentrations in urine; however, information about the short-term and long-term stabilities of AAs in urine need to be characterized before conducting large-scale population studies on AA exposure and the potentially harmful effects of AA exposure. In this report, the storage stability of o-toluidine, 2,6-dimethylaniline, o-anisidine, 1-aminonaphthalene, 2-aminonaphthalene, and 4-aminobiphenyl fortified in pooled, filtered, non-smokers' urine is analyzed by isotope dilution gas chromatography-triple quadrupole mass spectrometry (ID GC-MS/MS). The six AAs were measured in urine samples stored at ~20 °C (collection temperature), 4 °C and 10 °C (short-term transit temperatures), and -20 °C and -70 °C (long-term storage temperatures) over a 10-day period. All six analytes were stable for 10 days at transit and long-term storage temperatures but showed reduced recovery at 20 °C. The instability of the target AAs at 20 °C suggests that immediate storage of freshly voided urine at low temperatures is needed to attenuate degradation. A subset of the urine samples was analyzed following a longer storage duration at -70 °C: all AAs were stable for up to 14 months at this temperature. The stability of the six AAs in urine samples can be maintained at the various temperature levels and storage times expected in a typical study set. |
A new automated method for the analysis of aromatic amines in human urine by GC-MS/MS
Mazumder S , Ahamed RA , McGahee E , Wang L , Seyler TH . J Anal Toxicol 2018 43 (1) 25-35 Cigarette smoking significantly increases the risk of cancer and cardiovascular diseases as well as premature death. Aromatic amines (AAs) such as o-toluidine, 2-aminonaphthalene and 4-aminobiphenyl are found in cigarette smoke and are well-established human bladder carcinogens presumably acting via the formation of DNA adducts. These amines may be metabolized in the liver to acetylated or glucuronidated forms or oxidized to a hydroxylamine which may react with protein and DNA to form adducts. Free, acetylated and glucuronidated AAs are excreted in urine and can be measured as exposure biomarkers. Using isotope dilution GC-MS/MS, our laboratory quantifies six urinary AAs that are known or suspected carcinogens-o-toluidine, 2,6-dimethylaniline, o-anisidine, 1-aminonaphthalene, 2-aminonaphthalene and 4-aminobiphenyl-for large population studies such as the National Health and Nutrition Examination Survey (NHANES). We also monitor two additional corresponding structural isomers-2-aminobiphenyl and 3-aminobiphenyl-to verify isomer separation. A new and improved automated sample preparation method was developed to quantify these AAs, in which, sample cleanup was done via Supported Liquid Extraction (SLE+ ISOLUTE(R)) on a Hamilton STAR workstation. This automated method increased sample throughput by reducing sample cleanup time from 8 to 4 h while maintaining precision (intra and inter-run coefficient of variation <7%) and accuracy (+/-17%). Recent improvements in our GC/MS method have enhanced our assay sensitivity and specificity, resulting in longer analytical column life and maintaining or reducing the limit of detection for all six analytes. Indigo ASCENTTM software (3.7.1, Indigo BioAutomation, Inc.) is used for peak integration, calibration and quantification. A streamlined sample data flow was created in parallel with the automated method, in which samples can be tracked from receiving to final laboratory information management system output with minimal human intervention, minimizing potential human error. This newly validated, automated method and sample data flow are currently applied in biomonitoring of AAs in the US noninstitutionalized population NHANES 2013-2014 cycle. |
- Page last reviewed:Feb 1, 2024
- Page last updated:Apr 29, 2024
- Content source:
- Powered by CDC PHGKB Infrastructure